Download P0305: Procedure For Gyroscope High Voltage To Ground Plane

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Mercury-arc valve wikipedia , lookup

Stepper motor wikipedia , lookup

Power engineering wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Power inverter wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Portable appliance testing wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Electrical ballast wikipedia , lookup

Islanding wikipedia , lookup

Electrical substation wikipedia , lookup

Ground loop (electricity) wikipedia , lookup

Three-phase electric power wikipedia , lookup

Ohm's law wikipedia , lookup

Current source wikipedia , lookup

History of electric power transmission wikipedia , lookup

Ground (electricity) wikipedia , lookup

Metadyne wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Distribution management system wikipedia , lookup

Schmitt trigger wikipedia , lookup

Rectifier wikipedia , lookup

Power electronics wikipedia , lookup

Opto-isolator wikipedia , lookup

Power MOSFET wikipedia , lookup

Buck converter wikipedia , lookup

Triode wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Voltage regulator wikipedia , lookup

Surge protector wikipedia , lookup

Alternating current wikipedia , lookup

Stray voltage wikipedia , lookup

Voltage optimisation wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
P0305 Rev Gyroscope High Voltage to Ground Plane Test
P0305 Rev. -
Purpose:
To test coated electrodes and ground plane for no continuity
Materials and Supplies:
•
High Voltage power supply, calibrated to manufacturer’s specifications.
•
Keithly Model 617 Electrometer, calibrated to manufacturer’s specifications.
•
High vacuum test facility conforming to Stanford / NASA guidelines
•
Approved qualified personnel performing test battery
•
Traveler notebook for Gyro currently in Test.
•
Record data in GP-B Database in Gyro Coating and Testing Traveler
Process:
Test Set-Up:
Refer to High Voltage to Ground Plane Set-Up diagram on page 2.
For each electrode:
60
Ramp power supply to 1500 VDC in 100 V increments with a delay of ~ 30
seconds between voltage increases. Maintain 1500 VDC for > 60 minutes. After
minutes, increase the DC voltage to 2000 VDC in 100 V increments. Hold the
voltage at 2000 V for ~ 5 minutes, then ramp voltage down to 0 volts. Current
should be < 20pA at 2000VDC for each electrode. Record voltage and current in
P0305 Table 1 for each electrode.
P0305 Rev -
Gyroscope High Voltage to Ground Plane Test
P0305 Rev. -
Electrode
Ground Plane
Ammeter
DC High
Voltage
High Voltage to Ground Plane Set-Up
Gyroscope Assembly Serial No. __________________________
Electrode
Voltage
Current
High Voltage
Duration