Download dtk-pvp installation instructions

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Radio transmitter design wikipedia , lookup

Rectiverter wikipedia , lookup

Battle of the Beams wikipedia , lookup

Broadcast television systems wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Analog television wikipedia , lookup

Television standards conversion wikipedia , lookup

Serial digital interface wikipedia , lookup

Index of electronics articles wikipedia , lookup

Cellular repeater wikipedia , lookup

Home cinema wikipedia , lookup

Camcorder wikipedia , lookup

Interlaced video wikipedia , lookup

Videocassette recorder wikipedia , lookup

Electrical connector wikipedia , lookup

Telecommunications engineering wikipedia , lookup

Surge protector wikipedia , lookup

HD-MAC wikipedia , lookup

Ground loop (electricity) wikipedia , lookup

Transcript
DTK-PVP INSTALLATION INSTRUCTIONS
LOW VOLTAGE POWER AND VIDEO PROTECTION
NOTE: THIS DEVICE IS NOT INTENDED FOR DIRECT EXPOSURE THE ELEMENTS. USE A NEMA 4X
OR SIMILAR ENCLOSURE FOR OUTDOOR INSTALLATIONS.
1. CHECK THE POWER AND CABLE SIGNALS BEFORE INSTALLATION OF THE DTK-PVP TO VERIFY
NO SIGNAL DISTORTION.
2. POWER DOWN OR DISCONNECT THE CIRCUITS THIS DEVICE WILL CONNECT TO BEFORE
BEGINNING INSTALLATION.
3. SECURELY MOUNT THIS UNIT BETWEEN THE FIELD WIRING AND THE EQUIPMENT TO BE PROTECTED.
FOR MOUNTING, USE DOUBLE-SIDED TAPE OR TWO #8 SCREWS (PROVIDED).
4. NOTE: ALLOW THE SURGE PROTECTOR REACTION TIME BY PROVIDING 3-6 WIRE FEET OF CONDUCTOR
LENGTH BETWEEN THE DTK- UNIT AND THE EQUIPMENT TO BE PROTECTED.
5. NOTE: ALLOW FOR THE WIRE DISTANCE FROM THE SURGE PROTECTOR TO PROTECTED EQUIPMENT
TO BE GREATER THAN THE WIRE DISTANCE FROM THE SURGE PROTECTOR TO GROUND.
6. FOR GROUND CONNECTION: CONNECT A MINIMUM # 14 AWG WIRE FROM THE GROUND CONNECTOR
TO THE COMMON EARTH GROUND WITH 25 OHMS OR LESS (5 OHMS IS PREFERRED). USE ONE COMMON
GROUND PER SYSTEM TO ELIMINATE THE POSSIBILITY OF A DIFFERENCE IN GROUND POTENTIALS.
7. FOR VIDEO PROTECTION: CONNECT THE UNPROTECTED VIDEO CABLE INPUT FROM THE FIELD TO
THE BNC IN. CONNECT ONE END OF A SECOND VIDEO CABLE FROM THE BNC OUT THEN CONNECT
THE OTHER END OF THIS CABLE TO THE EQUIPMENT TO BE PROTECTED.
8. FOR 24V POWER PROTECTION: CONNECT THE SUPPLY WIRE FOR THE 24V POWER SUPPLY TO
THE UNPROTECTED 24V PWR TERMINALS MARKED IN. THE SUPPLY WIRE FROM THE PROTECTED
TERMINALS MARKED OUT CONNECTS TO THE EQUIPMENT TO BE PROTECTED.
9. AFTER ALL CONNECTIONS HAVE BEEN MADE AND NO HAZARDS EXIST, RESTORE POWER.
10. CHECK THE POWER AND CABLE SIGNALS AFTER INSTALLATION OF THE DTK-PVP TO INSURE
PROPER INSTALL AND NO SIGNAL DISTORTION.
11. FOR FURTHER INFORMATION OR TECHNICAL SUPPORT, PLEASE CAL 1-888-472-6100
CAMERA END
VIDEO SIGNAL
OUT
IN
PROTECTED
BNC CONNECTOR
VIDEO OUTPUT
VIDEO SIGNAL
UNPROTECTED
BNC CONNECTOR
VIDEO INPUT
VIDEO
GND
OUT
DTK-PVP
PROTECTED
IN
UNPROTECTED
24V PWR
24V PWR
OUT
VIDEO
IN
GND
24V PWR
DTK-PVP
P
R
O
T
E
C
T
E
D
MONITOR END
VIDEO SIGNAL
OUT
IN
VIDEO SIGNAL
VIDEO
24V POWER
CONNECTION
OUTPUTS
GND
PROTECTED
DTK-PVP
UNPROTECTED
U
N
P
R
O
T
E
C
T
E
D
24V PWR
24V PWR
OUT
GROUND
CONNECTOR
24V POWER
CONNECTION
INPUTS
IN
24V PWR
24V PWR
OUT
IN
24V PWR
OUT TO CAMERA
REV
Diversified Technology Group, Inc. 3
ONE DITEK CENTER
1720 Starkey Road, Largo Fl. 33771
1-800-753-2345
www.ditekcorp.com
4
DATE:
DESCRIPTION/ECN:
CHANGED TEXT
CHANGED INSTRUCTIONS
ADDED DIAGRAMS
DRAWN BY:
APP. BY:
06-03-02
JM
05-13-04
JM
DATE:
RWM
02-08-99
TITLE:
INSTALLATION INSTRUCTIONS FOR DTK-PVP
REV.
PART NO.
DWG NO.
INT-100071-001
191409
4