* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Generator Backup Protection System backup for generators and
Fault tolerance wikipedia , lookup
Electric power system wikipedia , lookup
Stepper motor wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Power inverter wikipedia , lookup
Electrical ballast wikipedia , lookup
Power engineering wikipedia , lookup
Ground loop (electricity) wikipedia , lookup
Current source wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Power MOSFET wikipedia , lookup
Electrical substation wikipedia , lookup
Distribution management system wikipedia , lookup
History of electric power transmission wikipedia , lookup
Ground (electricity) wikipedia , lookup
Voltage regulator wikipedia , lookup
Opto-isolator wikipedia , lookup
Protective relay wikipedia , lookup
Earthing system wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Buck converter wikipedia , lookup
Surge protector wikipedia , lookup
Stray voltage wikipedia , lookup
Voltage optimisation wikipedia , lookup
Three-phase electric power wikipedia , lookup
Generator Backup Protection 3 System backup for generators and transmission lines. Features and Benefits Applications ■ Waveform sampling of current and voltage inputs ■ Backup protection for generators or transmission lines ■ High-resolution oscillography and playback ■ Three-phase tripping applications ■ enerVista.com compatible (see page 275) ■ Four zones of phase and ground mho distance functions ■ Out-of-step blocking and tripping available ■ Out-of-step tripping ■ Over and undervoltage functions ■ Phase and ground overcurrent instantaneous backup Monitoring and Metering ■ Ground time overcurrent backup ■ User-configurable I/Os ■ Integrated RMS metering ■ Horizontal and vertical models Protection and Control ■ Fault location, event and fault recording ■ Currents, voltages, watts, vars and frequency User Interfaces ■ LCD and keypad ■ RS232 and RS485 serial ports GE Multilin 1 LPS-O™ Generator Backup Protection Protection and Control The LPS-O provides backup protection for generators and transmission lines. Advanced protection functions include: 3 Distance Four zones of phase step distance protection are provided. Functions are positive sequence voltage polarized mho characteristics. The reach of the three forward looking zones can be compensated for a delta-wye transformer. Zone 4 is reversed and disregards any transformer between the relay and the fault in the forward direction. Zones 1, 2, 3, and 4 each include independent timers for phase step distance protection. Out-of-step blocking monitors swing condition and blocks tripping. Out-of-step tripping logic is provided with a choice of two or three mho type characteristics with adjustable shapes. Forward and reverse share a common maximum reach angle. Loss of synchronism or a power swing between two areas of the power system is detected by measuring the positive sequence impedance seen by the relay over a period of time as the power swing develops. Directional Ground Overcurrent The ground directional functions are forward and reverse negative sequence current and voltage operated. The ground instantaneous and TOC functions can be independently set with directional control. Overcurrent Backup The LPS-O provides instantaneous phase and ground overcurrent functions. The phase backup consists of an instantaneous function. Ground overcurrent backup consists of IOC and TOC functions. The TOC function includes four selectable and one programmable curve. The ground overcurrent functions can be controlled by the directional functions. Both IOC and TOC functions can be set as nondirectional or directional. The LPS-O provides an adaptive sensitive current disturbance detector (fault detector) and an unbalanced current alarm to detect open or shorted CT leads. Voltage Three single-phase under and overvoltage detectors and a positive sequence overvoltage detector are provided. Configurable I/Os All 12 contact converter inputs and 20 contact outputs (except for alarms) are user-configurable. SCR tripping outputs are available for high speed operation. Monitoring and Metering The LPS-O provides sophisticated monitoring and metering functions that include: Trip Circuit Monitor Fuse failure logic detects a full or partial loss of AC potential and blocks tripping of distance and directional functions. The LPS-O has a three-wire voltage input suitable for either delta or wye connected VTs. DC battery voltage is monitored across each open trip contact. An alarm triggers when the voltage becomes virtually zero. A current sensor in series with each trip contact is provided, to log an event message on the DC trip current status following the trip. Scheme Logic Metering The LPS-O provides userprogrammable logic with up to 40 gates and eight timers. The LPS-O provides the following RMS metering values: ■ Current (Ia, Ib, Ic, In) ■ Voltage (Vab, Vbc, Vca) ■ Watts (three-phase) ■ Vars (three-phase) ■ Frequency Manual Breaker Control Manual circuit breaker tripping or closing can be done locally or remotely. Multiple Settings Groups Two separate groups of protection settings may be stored in the LPS-O non-volatile memory. The active settings group can be selected by the user. The currents are calculated for each phase, and voltages are calculated between phases. The accuracy is 1% of rated current and voltage. The phasor value (magnitude and angle) of the phase currents and voltages are also displayed. Functional Block Diagram G Metering 50P 21P 78 LPS-O 50/ 67N 67P 51G 27 59 lpso_fbd.ai 2 www.GEindustrial.com/Multilin LPS-O™ Generator Backup Protection The LPS-O stores up to 150 events with the date and time stamped to the nearest millisecond. This aids the user with determining the sequence of events, facilitating diagnosis and recovery. Typical Wiring A B C TRIPPING DIRECTION 52 CONNECTION AS REQUIRED C1 C2 C3 C4 C5 C6 C13 C14 C9 C10 C11 C12 Vs Va Vb Vc Vn C(B) A CURRENT INPUTS B(C) A8 CONTROL POWER GE Multilin T2 LPS T3 Line Protection System T5 CC1 T6 CC2 C1 CC3 CC4 CC5 CC6 CC7 CC8 CC9 C2 A1 A2 CC10 CC11 UNMODULATED IRIG-B Breaker Health OUTPUTS CC12 CONFIGURABLE (SHOWN WITH DEFAULT SETTINGS) The LPS-O relay can playback stored waveform files through the relays processor, allowing the user to playback faults with different settings. T4 INPUTS D2 D18 D3 D19 D4 D20 D5 D21 D6 D22 D7 D23 D8 D24 D9 D25 D10 D26 D11 D27 D12 D28 D13 D29 D1 D17 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 DB-9 RS232 PL1 (FRONT) KT1 KT2 PL2A (REAR) DB-25 RS-232 KT3 Self-Test Diagnostics 4 WIRE / 2 WIRE RS-485 DB-25 RS-232 KT4 PL2B (REAR) PL3 (REAR) OPTIONAL RS-485 OPTIONAL SINGLE POLE MODEL www.GEindustrial.com/Multilin FAULT LOCATION FIXED Self-test routines are performed during power up and continue in the background during service. Failures are categorized as either critical or non-critical alarm and recorded in the event log. A2 GROUND BUS VOLTAGE INPUTS T1 Oscillography can be triggered by internal or external signals. Internal signals include trip outputs or a programmable logic signal. The supplied out-of-step trip logic features a three second oscillography data file consisting of phasor values of the currents and voltages captured at a rate of one per cycle. The LPS-O has the capability to store the oscillography files in Comtrade format. The breaker health threshold is set by the user to achieve “just in time” maintenance. When the cumulative value of the three-phase currents exceeds the threshold, an alarm occurs. The user can adjust the threshold for breakers with previous duty. A1 A17 I A I AR I B I BR I C I CR Vs CONFIGURABLE (38.5 TO 300 VDC) The LPS-O captures current and voltage waveforms and selected internal logic signals at 64 samples per cycle. The unit can store from six events of 72 cycles each to 36 events of 12 cycles each. The time, date, active settings, and fault report are stored with the data capture. Prefault data can be set from one to eight cycles. 3 CONTROL POWER SUPPLY Oscillography GROUND SURGE Event Recording CRITICAL ALARM POWER SUPPLY ALARM I/V A3 A19 A4 A20 A5 A21 A6 A22 A7 A23 A8 A24 B27 B11 B28 B12 B29 B13 A9 A25 A10 A26 A11 A27 A12 A28 A13 A29 A14 A30 A15 A31 A16 A32 B1 B17 B2 B18 B3 B19 B4 B20 B21 B5 B22 B6 B23 B7 B24 B8 B25 B9 B26 B10 D16 D32 B30 B14 B31 B15 B32 B16 730750A3.CDR 3 LPS-O™ Generator Backup Protection LPS-O Technical Specifications Time Synchronization An IRIG-B input is provided for time synchronization via satellite signal. Security There are separate remote passwords which permit view only, view and settings changes, or view, settings, and control capability. 3 Software Windows®-based software packages are included in the LPS-O instruction book. ■ LPS-O LINK – allows communication with the relay using GE protocol ■ XPRESSION BUILDER™ – allows the user to graphically design programmable logic settings and I/O assignments The user may also obtain GE-DATA or GE-OSC to analyze oscillography data. LPS-O Guideform Specifications For an electronic version of the LPS-O guideform specifications, please visit: www.GEindustrial.com/ Multilin/specs, fax your request to 905-201-2098 or email to [email protected]. PROTECTION In = 1 45 – 90° 45 – 90° Positive sequence angle: Zero sequence angle: Zero sequence current : Compensation (K0): Zone 1, 2, 3 and 4 reach: Zone 4 offset reach: In = 5 45 – 90° 45 – 90° 1.00 – 7.00 1.00 – 7.00 0.05 – 250 Ω 0.01 – 50 Ω 0.00 – 0.40 0.00 – 0.40 (Zone 4 is reversible) 0.10 – 3.00 sec 0.10 – 3.00 sec 0.10 – 10.0 sec 0.10 – 10.0 sec 0.4 – 32 A 2.0 – 160.0 A 0.1 – 16.0 A 0.5 – 80.0 A 0.04 – 3.00 A 0.20 – 15.00 A Inverse, very inverse, extremely inverse, definite and custom Zone 2 timer: Zone 3 and 4 timers: Phase instantaneous OC: Ground instantaneous OC: Ground TOC: TOC curves: RECLOSURE (OPTIONAL) Reclose attempts: Synchronism check: 4 Optional METERING Frequency: Voltage (ph-ph): Current (In): Maximum permissible current: Continuous: MONITORING Records: Record length: Pre-fault cycles: Samples per cycle: 3 A for In = 1 A 15 A for In = 5 A 50 x In 100 x In 138 VAC (ph-n) 3.5 x rated 0.02 Ω at 5° 0.12 Ω at 30° 0.20 VA 0.15 VA In = 1 In = 5 50 Hz 60 Hz DC battery: Power supply: Contact converters: <20 W 2.5 mA each POWER SUPPLY Control voltage: 48 VDC 110/125 VDC 220/250 VDC High speed (KT1 – KT4): Continuous = 5 A Make & carry = 30 A Interrupting: 25 VA Pickup <8 ms Continuous = 0.5 A Max voltage = 280 VDC = Pickup <0.5 ms ENVIRONMENTAL Ambient temperature range: Storage: -30° C to +75° C Operation: -20° C to +60° C Humidity: 95% without condensation 5 – 300 VDC (jumper selectable) Voltage circuits: Auxiliary (A1 – A12): (C1, C2): INSTRUCTION BOOK Single-pole GEK 106202 Three-pole GEK 106159 6 – 36 72 – 12 cycles 1–8 64 INPUTS Contact converter inputs: BURDENS Current circuits: Trip SCR (T1 – T6): Continuous = 5 A Make & carry = 30 A per ANSI C37.90 Interrupting: 25 VA Pickup <4 ms Continuous = 5 A Make & Carry = 30 A per ANSI C37.90 COMMUNICATIONS Protocol: ASCII, GE-MODEM Ports: Front: 1 DB9, RS232 Rear: 1 DB25, RS232 and 4 pin Phoenix, RS485 (standard): 1 DB25, RS232 or RS485 optional Display: 4 line liquid crystal display standard Keypad: Full numeric keypad standard 50 or 60 Hz 100 – 120 VAC 1 or 5 A Three sec: One sec: Maximum permissible AC voltage: Continuous: One minute: OUTPUTS CONTACT RATINGS Trip contact (T1 – T6): Range: 38.5 – 60.0 VDC 88 – 150 VDC 176 – 300 VDC TYPE TESTS Insulation test voltage: 2 kV, 50/60 Hz, 1 min (high-pot) ANSI C37.90 IEC 255-5 Impulse voltage withstand fast transient: 5 kV peak, 1.2/50 µs, 0.5 J IEC 255-4 ANSI C37.90.1 Surge withstand capability (SWC): ANSI C37.90.1 IEC 255-22-1 Radio frequency interference withstand (RFI): ANSI C37.90.2 IEC 255-22-3 Electrostatic discharge (ESD): IEC 255-22-2 *Specifications subject to change without notice. Ordering LPS * * * * * * * * * * ** LPS O B 3 5 U NOTE: For dimensions see ALPS brochure. 0 1 2 1 2 3 H V E 1 N enerVista enabled See page 275. www.enerVista.com ™LPS-O is a trademark of GE Multilin. 4 Line protection system Phase distance relay with out-of-step tripping (system phase backup) Revision level B Three-phase tripping logic 5 A rated current For applications without series capacitors 48 VDC battery voltage 110/125 VDC battery voltage 220/250 VDC battery voltage SCR trip outputs and contact channel interface Contact trip outputs and contact channel interface Front RS232 com port and 2 selectable RS232/RS485 rear port (GE-MODEM/ASCII) Horizontal mounting Vertical mounting Extended oscillography memory With out-of-step tripping No reclosure Accessories: 158D7358P1 158D7359P1 L2 Flange for vertical mounting KD Flange for vertical mounting www.GEindustrial.com/Multilin