* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download PFCI 100 115 HF
Electrical substation wikipedia , lookup
Linear time-invariant theory wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Electrification wikipedia , lookup
Three-phase electric power wikipedia , lookup
Current source wikipedia , lookup
Stray voltage wikipedia , lookup
Scattering parameters wikipedia , lookup
Power factor wikipedia , lookup
History of electric power transmission wikipedia , lookup
Control system wikipedia , lookup
Power engineering wikipedia , lookup
Audio power wikipedia , lookup
Flip-flop (electronics) wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Power inverter wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Analog-to-digital converter wikipedia , lookup
Two-port network wikipedia , lookup
Voltage optimisation wikipedia , lookup
Integrating ADC wikipedia , lookup
Alternating current wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Voltage regulator wikipedia , lookup
Mains electricity wikipedia , lookup
Distribution management system wikipedia , lookup
Schmitt trigger wikipedia , lookup
Buck converter wikipedia , lookup
PFCI 100-115 HF Power Factor Corrector 100W Input/output isolated Wide input range: 85 - 132VAC / 360-800Hz High efficiency up to 82% Compact size: 4,6" x 2,4" x 0.78" 0,97 Power factor EN 55022 Class A. CE Mark for LVD With the PFCI series, CONVERGIE is introducing a new concept of Power Factor Corrector. Through its I/O isolation, an integrated filter and an integrated signal generation, this module is designed to reduce product development time and minimize the number of external components. The PFCI series is available in 2 different models with 2 output voltages, 24 or 48V.PFCI is characterized by conformity to safety standard and is well suited for use in distributed power system. POWER FACTOR CORRECTOR Input Specifications MODEL Output Specifications min. max. nom. Frequency Vout1 Iout1 power (VAC) (VAC) (VAC) (Hz) (VDC) (A) (W) PFCI 100-115 HF 85 132 115 360-800 24 4,2 100 PFCI 100-115 HF 85 132 115 360-800 48 2,1 100 CONNECTION DIAGRAM PFCI 100-115 HF Electrical Specifications Condition PFCI 100-115 HF Tc = -40 to + 85°C Iout = 0 to 100% time period = 0,1s Vin nom. Vin min.; Iout max. see note1 see note2 Vin min. to Vin max. BW=20MHz see note3 Vin nom.; Iout nom. Fixed 1 Min. In / Out 1 Min. 1 Min. see note4 Ta Ts Tc UL94V-0 Ground Bening; Ta = +25°C 115V 360 to 800 Hz 85 to 132V 140V 40mA 1,50A ±10% ±10% ±10% 110% to 150% ±10% YES YES 75 VAC to 85 VAC 0,97 +/-0,02%/°C <1 ms 82% 120Khz 2500 VAC 1500 VAC 500VAC 4°C/W Tc > 110°C -25°C to +70°C -40°C to +105°C + 100°C Aluminium substrat with plastic box >500000 h 300g Power Factor Corrector Parameters Nominal input voltage Input Frequency Input over range Input over voltage No load input current Input current max. Output voltage accuracy Load régulation Line régulation Limitation range Output ripple peak to peak Parallel boost Remote ON/OFF AC FAIL Power Factor Temperature coefficient Transient response time Efficiency Switching Frequency Isolation Input/Output Isolation Input/Case Isolation Output/Case Thermal Impedance Thermal Protection Operating temperature range Storage temperature Maximum base plate temp. Case material MTBF (MIL-HDBK-217-F) Weight All specifications are typical, 25°C ambient , with nominal input voltage and underfull output load conditions, unless otherwise stated.It is recommended to protect the input by fuses or other protection devices. Fuses are never supplied internally, and without them, severe damage or even fire can occur in the event of a module failure. A slow fuse with a rating of 2x the Iin max. is recommended. In low noise applications it is recommended that a low ESR capacitor be placed across the input pins, and output pins. Pin connections Note 1: To obtain the voltage accuracy, a capacitor should be placed across the output pins as shown on the diagram connections, recommended value is 3300 µF/50 V. Pin Number 3 6 9 11 12 13 14 15 16 18 CONVERGY N L +VS -VS SD GND AC FAIL GND SD AC FAIL -VS +VS Note 2: Load regulation is specified from 70% load to full load for the PFCI 100-115. Note 3: 50 to 100% within 1% Vo. Note 4: Application note THERM PFCI provides detailed thermal considerations.