Download IMPLEMENTATION AND PERFORMANCE EVALUATION OF A

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Mercury-arc valve wikipedia , lookup

Spark-gap transmitter wikipedia , lookup

Power engineering wikipedia , lookup

Stepper motor wikipedia , lookup

Ground loop (electricity) wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Capacitor wikipedia , lookup

Electrical ballast wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Ohm's law wikipedia , lookup

Integrating ADC wikipedia , lookup

History of electric power transmission wikipedia , lookup

Power inverter wikipedia , lookup

Current source wikipedia , lookup

Metadyne wikipedia , lookup

Triode wikipedia , lookup

Electrical substation wikipedia , lookup

Schmitt trigger wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Power MOSFET wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Islanding wikipedia , lookup

Rectifier wikipedia , lookup

Three-phase electric power wikipedia , lookup

Opto-isolator wikipedia , lookup

Surge protector wikipedia , lookup

Power electronics wikipedia , lookup

Voltage regulator wikipedia , lookup

Buck converter wikipedia , lookup

Alternating current wikipedia , lookup

Stray voltage wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Voltage optimisation wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
IMPLEMENTATION AND PERFORMANCE EVALUATION
OF A FAST DYNAMIC CONTROL SCHEME FOR
CAPACITOR-SUPPORTED INTERLINE DVR
ABSTRACT
Electronic systems operate properly as long as the supply voltage stays within a
consistent range. There are several types of voltage fluctuations that can cause the systems to
malfunction, including surges and spikes, sags, harmonic distortions, and momentary
disruptions. Among them, voltage sag is the major power-quality problem.
Dynamic voltage restorer (DVR) is presently one of the most cost-effective and thorough
solutions to mitigate voltage sags by establishing proper quality voltage level for utility
customers. Its function is to inject a voltage in series with the supply and compensate for the
difference between the nominal and sagged supply voltage. The injected voltage is typically
provided by an inverter, which is powered by a dc source, such as batteries, flywheels, externally
powered rectifiers, and capacitors.
The implementation of a fast dynamic control scheme for capacitor supported interline
dynamic voltage restorer (DVR) is presented in this project. The power stage of the DVR
consists of three inverters sharing the same dc link via a capacitor bank. Each inverter has an
individual inner control loop for generating the gate signals for the switches. The inner loop is
formed by a boundary controller with second-order switching surface, which can make the load
voltage ideally revert to the steady state in two switching actions after supply voltage sags, and
also gives output of low harmonic distortion.
The load-voltage phase reference is common to all three inner loops and is generated by
an outer control loop for regulating the dc-link capacitor voltage. Such structure can make the
unsagged phase(s) and the dc-link capacitor to restore the sagged phase(s). The rectifier-based
source requires a separate service supply, while the battery-based source requires regular
maintenance and is not environment friendly. No external source is required in the DVR. The
computation method is purely based on sinusoidal waveforms; the implementation is
complicated in distribution network with nonlinear load. Based on the steady-state and smallsignal characteristics of the control loops, a set of design procedures are provided.
Head office: 2nd floor, Solitaire plaza, beside Image Hospital, Ameerpet, Hyderabad
www.kresttechnology.com, E-Mail : [email protected] , Ph: 9885112363 / 040 44433434
1
By integrating a recently proposed boundary-control method with second-order switching
surface (inner loop), the dynamic response has been minimized to two switching actions. Longduration voltage sags, swell, and three-phase voltage unbalance could be overcome by the
proposed power-flow controller (outer loop). The quality of the load voltage under unbalanced
and distorted phase voltages, and nonlinear inductive loads will be studied.