* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Compressor starting current too high?
Electric motor wikipedia , lookup
Electrification wikipedia , lookup
Electrical ballast wikipedia , lookup
Three-phase electric power wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Commutator (electric) wikipedia , lookup
Voltage optimisation wikipedia , lookup
History of electric power transmission wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Stray voltage wikipedia , lookup
Electric machine wikipedia , lookup
Opto-isolator wikipedia , lookup
Buck converter wikipedia , lookup
Surge protector wikipedia , lookup
Mains electricity wikipedia , lookup
Current source wikipedia , lookup
Induction motor wikipedia , lookup
Brushed DC electric motor wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Rectiverter wikipedia , lookup
Alternating current wikipedia , lookup
Compressor starting current too high? - Reduce compressor starting current by up to 40% - Eliminate the damaging effects of high starting torque surges - Fast and reliable start - pressure equalization not necessary ... and the MCI is as easy to specify and install as an ordinary contactor Reduce starting current with compressor softstarter MCI 15C and MCI 25C Universal control voltage 24-480 V a.c./d.c. Automatic adaption to 50/60 Hz Line voltage 400-480 V a.c. Automatic detection of phase failure LED status indication Unlimited number of starts per hour Approved for use with Danfoss Performer scroll and Maneurop reciprocating compressors • Nominal motor current max 30 A • Code no. 037N0077 • Nominal motor current max 15 A • Code number 037N0076 Avoid peaks, save electricity and prolong life time of your compressor up to 40% lower 6-8 x l e Without MCI Installation With MCI Normal high starting current when compressor is started direct (DOL) • Easy installation • No adjustments necessary • Pre-set for optimum performance Soft start current with MCI 15/25 The starting procedure of refrigeration and airconditioning compressors with electric motors always implies starting current peaks. With the MCI Compressor Starter the starting current peak can be reduced by up to 40 % on most compressors. At the same time the MCI Compressor Starter ensures a fast and reliable start - below 0,4 seconds - even without a pressure equalization in the refrigeration circuit. The start time and initial torque parameters of the MCI Compressor Starters are pre-set to ensure optimum performance. More information can be obtained in our data sheet code no. 520B0754. In addition to the MCI Compressor Starter Danfoss offers a broad range of soft starters with potentiometers for individual ramp time and torque settings. DKACT.PB.C50.B1.02/520B0910 05. 2001 Danfoss A/S, AC-TMP/ht