* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download CIM800 Contact Input Module Datasheet
Power MOSFET wikipedia , lookup
Oscilloscope history wikipedia , lookup
Phase-locked loop wikipedia , lookup
Wien bridge oscillator wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Index of electronics articles wikipedia , lookup
Printed circuit board wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Schmitt trigger wikipedia , lookup
Transistor–transistor logic wikipedia , lookup
Valve RF amplifier wikipedia , lookup
Regenerative circuit wikipedia , lookup
Operational amplifier wikipedia , lookup
Rectiverter wikipedia , lookup
Opto-isolator wikipedia , lookup
Surge protector wikipedia , lookup
RLC circuit wikipedia , lookup
Integrated circuit wikipedia , lookup
Flexible electronics wikipedia , lookup
CIM800 Generation 6 MX Detection Range - Contact Input Module Features // MX Addressable Module // Supervise Two Circuits // Supervise Multiple Contacts per Circut // Up to 250 Devices per Loop2 Description The CIM800 Addressable Contact Input Module supervises two circuits of voltage-free contacts such as outputs from extinguishing systems, ventilation controls, fire door controls, sprinkler flow switches, non indicating detectors, etc. The LED illuminates when any input goes into alarm, and can also be programmed to blink when polled by the Tyco MX Control and Indicating Equipment (CIE.). The CIM800 can be configured to supervise: · Two circuits of multiple normally-open contacts; with short circuit alarm. · Two circuits of multiple normally-closed contacts; open circuit alarm. · Two circuits with a single normally-open contact closing for alarm; with short circuit fault. This requires a resistor in series with the alarm contact and special programming at the MX4428 CIE. On the MX4428, the two circuits are presented as a single addressable point; either circuit in alarm puts the point into alarm, any circuit in fault puts the point into fault. Mounting The CIM800 is supplied as an open circuit board (PCB) with mounting hardware and End of Line (EOL) resistors. It must be fitted in a suitable enclosure. It may be mounted on a gear plate using plastic standoffs, to an M520 Ancillary Cover and K2142 back box, or into the D800 Ancillary Housing. The K2142 mounting box provides a convenient surface mounting enclosure and the M520 Cover is designed to accommodate the CIM800. The contacts supervised must be voltage free. Do not connect the two circuits of a CIM800 together or join with other MX module inputs. Unused inputs must be terminated with an EOL resistor. Specifications Loop Voltage1 20V to 40Vdc Quiescent Current 275µA Alarm State Current 2.8mA Circuit Resistance 10 Ohm EOL Resistor 200 Ohm Alarm Resistance (s/c fault) 100 Ohm Max. CIM800 per Loop2200/250 Ambient Temperature –25°C to +70°C Storage Temperature –40°C to +80°C Relative Humidity 10% to 95% (non cond.) Indoor Applications Only Dimensions (HWD) 61 x 84 x 25 mm Wire Size (maximum) 2.5sq. mm ActivFire Listing afp-1446 FPANZ Listing VF/640 Part Numbers CIM800 CIM800 PCB 3 M520 Ancillary Cover 517.035.010 K2142 Back Box 557.201.401 D800 Ancillary Housing 1. Addressable loop voltage provided by MX CIE. 2. MX4428/MX1, 4100MXP. Refer to appropriate manual: LT0273 (MXP), LT0313 (4100MXP), LT0360 (MX1-NZ), LT0441 (MX1-Au) for design specifications. 3. PCB c/w EOL resistor, mounting screws, cover labels. Address Setting The CIM-800 is supplied with a default (invalid) address of 255 and must be set to the correct loop address using the 850EMT or 801AP MX Service Tool and programming lead. Wiring CIM800 Wiring Options. MX4428 Requires Param_2 = 176 ANALOG LOOP PREVIOUS DEVICE L+ L- L+ L- ANALOG LOOP NEXT DEVICE TB1 TB2 PREVIOUS DEVICE A+ A- B+ B- L+ L- L+ L- CIM800 CONTACT MODULE 200 ohm EOL PREVIOUS DEVICE L+ L- L+ L- TB1 TB2 100 ohm 200 ohm EOL NEXT DEVICE TB1 TB2 A+ A- B+ B- Normally Open, S/C = Fault 200 ohm EOL NEXT DEVICE 100 ohm CIM800 CONTACT MODULE Normally Open ANALOG LOOP 200 ohm EOL 200 ohm EOL 200 ohm EOL Unused inputs (A or B) must be terminated with a 200 ohm EOL resistor. A and B inputs must be voltage free. A+ A- B+ B- CIM800 CONTACT MODULE Normally Closed Australia Tyco Fire Protection Products Level 3, 95 Coventry Street Southbank VIC 3006 Tel : 1300 725 688 Tel : +61 3 9313 9700 Email : [email protected] New Zealand Tyco Fire Protection Products 17 Mary Muller Drive Hillsborough PO Box 19-545 Woolston Christchurch 8241 Tel : +64 9 635 0760 Email : [email protected] Copyright © 2015 Tyco Australia Pty Limited. All rights reserved. Tyco reserves the right to make changes to any aspect of this publication at any time without notice. VIGILANT is a trademark of Tyco New Zealand Limited or its affiliates; MX TECHNOLOGY is a trademark of Thorn Security Limited or its affiliates; VESDA is a trademark of Xtralis Technologies Ltd; TYCO is a trademark of Tyco International Services GmbH. CIM800datTFPP1505