Download Lightplane 1 Recessed (LP1R) Install Instructions

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Loudspeaker wikipedia , lookup

Electrification wikipedia , lookup

Audio power wikipedia , lookup

Buck converter wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Electrician wikipedia , lookup

History of electric power transmission wikipedia , lookup

Power over Ethernet wikipedia , lookup

Power engineering wikipedia , lookup

Ground (electricity) wikipedia , lookup

Stray voltage wikipedia , lookup

Voltage optimisation wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Transmission line loudspeaker wikipedia , lookup

Three-phase electric power wikipedia , lookup

Gender of connectors and fasteners wikipedia , lookup

Single-wire earth return wikipedia , lookup

Overhead line wikipedia , lookup

Telecommunications engineering wikipedia , lookup

Loudspeaker enclosure wikipedia , lookup

Alternating current wikipedia , lookup

Wire wrap wikipedia , lookup

Electrical wiring wikipedia , lookup

Mains electricity wikipedia , lookup

National Electrical Code wikipedia , lookup

Transcript
LIGHTPLANE 1 RECESSED
Installation Guide
IMPORTANT SAFETY INSTRUCTIONS
When installing or using this recessed fixture basic safety precautions should be followed
Read ALL INSTRUCTIONS before installing fixture.
•This fixture is intended for installation in accordance with the National Electric Code
and Local and State Codes and must be installed by a licensed electrical contractor.
•DO NOT INSTALL FIXTURE WITHOUT A MINIMUM 1/2 INCH CLEARANCE ALL AROUND THE
FIXTURE. ENSURE CLEARANCE AT TOP OF CHANNEL IS 1 INCH.
• THIS FIXTURE IS FOR INSTALLATION IN NON NSULATED CEILINGS ONLY.
•To prevent electrical shock, turn off electricity at fuse box before installing the fixture.
•Turn off power and allow fixture to cool down before adjusting position of lamp gimbals.
•Use AWG#14 wire only for supply to the fixture.
Electrical Data
Fixture uses a listed 120v rated single circuit track. Minimum 15 Amps
Black
Input
White
Neutral
Ground
DO NOT CONNECT BUILDING POWER DIRECTLY TO LED. PERMANENT LED DAMAGE,
RISK OF FIRE AND ELECTROCUTION WILL RESULT.
SAVE THESE INSTRUCTIONS
Tel: (510) 489-2530 Fax: (650) 249-0412 web: www.alwusa.com
LIGHTPLANE 1 RECESSED - TRIM (LP1RT)
DROP TILE CEILING - Installation Guide
NOTICE:
For proper installation, have a qualified electrician install this product. Before installation of any luminary onto
an electrical junction box, be sure to disconnect power. This luminary must be wired and grounded in accordance with the National Electrical Code, local codes, and ordinances. Wire supply connections must be made
with U.L. or ETL approved connectors. Check that luminary voltage and building voltage are the same.
CAUTION:
EXERCISE SPECIAL CARE AND SAFETY WHILE INSTALLING AND SERVICING LUMINARY. USE OF SOFT GLOVES AND
PADDED MATERIALS ARE RECOMMENDED DURING HANDLING TO AVOID MARRING THE FINISH.
2” SPACING
9/16” SUSPENDED
GRID CEILING
(SHOWN)
LPLR-1 (22 38”)
8-32 ALLTHREAD/BRACKET LOCATION
BUILDING STRUCTURE
BUILDING STRUCTURE
CEILING
BRACKET
SUPPORT
WIRE
CEILING
BRACKET
T-GRID
T-GRID
T-GRID
SUSPENDED
CEILING
BRACKET
COVER
PLATE
SUSPENDED
CEILING
BRACKET
8-32
ALLTHREAD
T-GRID
T-GRID
SCREWS
SCREWS
2”
2”
4”
2”
LAY IN
INSTALLATION
BRACKET &
SUPPORT WIRE
INSTALLATION
4” T-GRID
INSTALLATION
(WITH SLOTTED COVER)
8-32 ALLTHREAD
2” T-GRID
INSTALLATION
INSTALLATION EXAMPLES
INSTRUCTION:
1. TURN OFF POWER at fuse box before installing
fixture.
2. Install REMOTE DRIVER enclosure in an accessible location (distance as indicated by driver
specification) from the LED.
Provide conduit, Pull String or provide other
access to bring CORD from the WIREBODY to
the REMOTE DRIVER. Secure REMOTE DRIVER to
building structure with hardware as needed.
(By Others).
3. If Joining multiple LED segments remove back
cover and secure segments together using
JOINING BAR set screws. Each segment
requires a separate CORD and may require a
separate REMOTE DRIVER.
4. T-GRID should be installed to provide a 1in
wide SURFACE OPENING for WIREBODY and
LENS. Use appropriate support hardware as
needed. (See Below)
5. Suitable SUPPORT RODS to building structure or
appropriate brackets should be installed
before installing fixture. The Suspended Ceiling
must be independently supported from the
fixture and spaced to fit the fixture width and
length before installing the fixture.
6. While protecting finished parts and supporting
the fixture, pull CORD(s) to the REMOTE DRIVER(s) and insert CORD through KNOCKOUT in
the enclosure and connect to driver output. If
connector is provided on the CORD than
attach end of CORD to the connector. Secure
excess CORD as needed.
7. Connect Building Power to the REMOTE DRIVER
using U.L. approved wire connectors: connect
the luminary neutral (white) to the supply
neutral, connect the luminary line wire (black)
to the supply line wire. Fasten ground wire(s)
(Green) to ground wire.
8. Install WIREBODY into T-GRID using BRACKETS
and secure with support hardware as needed
using one of the suitable methods illustrated.
9. Install LENS(s) If needed.
10. Turn On Power
Tel: (510) 489-2530 Fax: (650) 249-0412 web: www.alwusa.com
LIGHTPLANE 1 RECESSED - TRIM (LP1RT)
DRYWALL - Installation Guide
NOTICE:
For proper installation, have a qualified electrician install this product. Before installation of any luminary onto
an electrical junction box, be sure to disconnect power. This luminary must be wired and grounded in accordance with the National Electrical Code, local codes, and ordinances. Wire supply connections must be made
with U.L. or ETL approved connectors. Check that luminary voltage and building voltage are the same.
CAUTION:
EXERCISE SPECIAL CARE AND SAFETY WHILE INSTALLING AND SERVICING LUMINARY. USE OF SOFT GLOVES AND PADDED MATERIALS ARE RECOMMENDED DURING HANDLING TO AVOID MARRING THE FINISH.
BUILDING
POWER
SURFACE
OPENING
REMOTE
DRIVER
INSTRUCTION:
1. TURN OFF POWER at fuse box before installing
fixture.
2. Install REMOTE DRIVER enclosure in an accessible location (distance as indicated by driver
specification) from the LED.
Provide Conduit, Pull String or provide other
access to bring CORD from the WIREBODY to
the REMOTE DRIVER. Secure REMOTE DRIVER to
building structure with brackets or blocking as
needed (By Others). Provide a 1-1/16 in. wide
SURFACE OPENING for WIREBODY and appr
priate support for SPRING CLIPS as needed.
(See Below)
CORD
WIREBODY
LENS
3
2 16 "
3. If Joining multiple LED segments remove back
cover and secure segments together using
JOINING BAR set screws. Each segment
requires a separate CORD and may require a
separate REMOTE DRIVER.
V4. While protecting finished parts and supporting
the fixture, pull CORD(s) to the REMOTE DRI
1-1/16”
ER(s) and insert CORD through KNOCKOUT in
Ceiling
the enclosure and connect to driver output. If
Cutout
connector is provided on the CORD than
attach end of CORD to the connector. Secure
excess CORD as needed.
5. Connect Building Power to the REMOTE DRIVER
using U.L. approved wire connectors: connect
the luminary neutral (white) to the supply
neutral, connect the luminary line wire (black)
SPRING CLIP
to the supply line wire. Fasten ground wire(s)
INSTALLATION
(Green) to ground wire.
6. Install WIREBODY into SURFACE OPENING using
supplied SPRING CLIPS.
7. Install LENS(s)
8. Turn On Power
Tel: (510) 489-2530 Fax: (650) 249-0412 web: www.alwusa.com
LIGHTPLANE 1 RECESSED - TRIMLESS (LP1RMUD)
DRYWALL - Installation Guide
NOTICE:
For proper installation, have a qualified electrician install this product. Before installation of any luminary onto
an electrical junction box, be sure to disconnect power. This luminary must be wired and grounded in accordance with the National Electrical Code, local codes, and ordinances. Wire supply connections must be made
with U.L. or ETL approved connectors. Check that luminary voltage and building voltage are the same.
CAUTION:
EXERCISE SPECIAL CARE AND SAFETY WHILE INSTALLING AND SERVICING LUMINARY. USE OF SOFT GLOVES AND PADDED MATERIALS ARE RECOMMENDED DURING HANDLING TO AVOID MARRING THE FINISH.
INSTRUCTION:
1. TURN OFF POWER at fuse box before installing
fixture.
2. Install REMOTE DRIVER enclosure in an accessible location (distance as indicated by driver
specification) from the LED.
Provide Conduit, Pull String or provide other
access to bring PLENUM CABLE from the
EXTRUSION to the REMOTE DRIVER. Secure
REMOTE DRIVER to building structure with
brackets or blocking as needed (By Others).
Provide a 1-7/16 in. wide SURFACE OPENING
for WIREBODY and appropriate support for
WIREBODY WING mounting.
3. If Joining multiple LED segments remove back
cover and secure segments together using
JOINING BAR set screws. Each segment
requires a separate PLENUM CABLE and may
require a separate REMOTE DRIVER.
4. While protecting finished parts and supporting
the fixture, pull PLENUM CABLE(s) to the
REMOTE DRIVER(s) and insert PLENUM CABLE
through KNOCKOUT in the enclosure and
connect to driver output. If connector is
provided on the PLENUM CABLE then attach
end of PLENUM CABLE to the connector.
Secure excess PLENUM CABLE as needed.
5. Connect Building Power to the REMOTE DRIVER
using U.L. approved wire connectors: connect
the luminary neutral (white) to the supply
neutral, connect the luminary line wire (black)
to the supply line wire. Fasten ground wire(s)
(Green) to ground wire.
6. Install WIREBODY into SURFACE OPENING by
securing WIREBODY to blocking using
MOUNTING HARDWARE by others. SHEETROCK
shall then be placed over WIREBODY WING.
PLASTER will then be used to fill in remaining
gaps around WIREBODY LENS opening.
7. Install LENS(s)
8. Turn On Power
Tel: (510) 489-2530 Fax: (650) 249-0412 web: www.alwusa.com
LIGHTPLANE 1 RECESSED - WALLWASH TRIM (LP1RWWT)
DRYWALL - Installation Guide
NOTICE:
For proper installation, have a qualified electrician install this product. Before installation of any luminary onto
an electrical junction box, be sure to disconnect power. This luminary must be wired and grounded in accordance with the National Electrical Code, local codes, and ordinances. Wire supply connections must be made
with U.L. or ETL approved connectors. Check that luminary voltage and building voltage are the same.
CAUTION:
EXERCISE SPECIAL CARE AND SAFETY WHILE INSTALLING AND SERVICING LUMINARY. USE OF SOFT GLOVES AND
PADDED MATERIALS ARE RECOMMENDED DURING HANDLING TO AVOID MARRING THE FINISH.
BUILDING
POWER
INSTRUCTION:
1. TURN OFF POWER at fuse box before installing
fixture.
2. Install REMOTE DRIVER enclosure in an accessible location (distance as indicated by driver
specification) from the LED.
REMOTE
DRIVER
Provide Conduit, Pull String or provide other
access to bring CORD from the WIREBODY to
the REMOTE DRIVER. Secure REMOTE DRIVER to
building structure with brackets or blocking as
needed (By Others). Provide a 1-7/8 in. wideoSURFACE OPENING for WIREBODY and appr
priate support for SPRING CLIPS as needed.
(See Below)
WIREBODY
SPRING
CLIPS
TOP COVER
ACCESS
Cord
DRYWALL
3. If Joining multiple LED segments remove back
cover and secure segments together using
JOINING BAR set screws. Each segment
requires a separate CORD and may require a
separate REMOTE DRIVER.
4. While protecting finished parts and supporting
the fixture, pull CORD(s) to the REMOTE DRI
ER(s) and insert CORD through KNOCKOUT in
the enclosure and connect to driver output. If
connector is provided on the CORD than
attach end of CORD to the connector. Secure
excess CORD as needed.
5. Connect Building Power to the REMOTE DRIVER
using U.L. approved wire connectors: connect
the luminary neutral (white) to the supply
neutral, connect the luminary line wire (black)
to the supply line wire. Fasten ground wire(s)
(Green) to ground wire.
6. Install WIREBODY into SURFACE OPENING using
supplied SPRING CLIPS.
7. Turn On Power
Tel: (510) 489-2530 Fax: (650) 249-0412 web: www.alwusa.com
LIGHTPLANE 1 RECESSED - TRIM (LP1RT)
DROP TILE CEILING - Installation Guide
NOTICE:
For proper installation, have a qualified electrician install this product. Before installation of any luminary onto
an electrical junction box, be sure to disconnect power. This luminary must be wired and grounded in accordance with the National Electrical Code, local codes, and ordinances. Wire supply connections must be made
with U.L. or ETL approved connectors. Check that luminary voltage and building voltage are the same.
CAUTION:
EXERCISE SPECIAL CARE AND SAFETY WHILE INSTALLING AND SERVICING LUMINARY. USE OF SOFT GLOVES AND
PADDED MATERIALS ARE RECOMMENDED DURING HANDLING TO AVOID MARRING THE FINISH.
MAXIMUM REMOTE DRIVER DISTANCE*
Driver
18 Wire
Gauge
18 Wire Gauge
w/ Remote
Emergency
LOW,MED,HI
DECOR
LOW,MED,HI
DECOR
0/10V/
120 ft
18 ft
10 ft
10ft
DALI
DMX
72 ft
Consult
Factory
10 ft
Consult
Factory
HILUME/A3
22 ft
15 ft
10 ft
10 ft
* aximum distance includes length of power feed
cable suspended from remote driver to luminaire.
Ex: 72' max length - 3' suspension = 69' available to run
from remote driver to building power.
Tel: (510) 489-2530 Fax: (650) 249-0412 web: www.alwusa.com