* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Test report of plants of over 16A and max 75 A
Pulse-width modulation wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Electromagnetic compatibility wikipedia , lookup
Power engineering wikipedia , lookup
Electrical ballast wikipedia , lookup
Current source wikipedia , lookup
Portable appliance testing wikipedia , lookup
Opto-isolator wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Electrical substation wikipedia , lookup
Power inverter wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
History of electric power transmission wikipedia , lookup
Automatic test equipment wikipedia , lookup
Electrical grid wikipedia , lookup
Three-phase electric power wikipedia , lookup
Power MOSFET wikipedia , lookup
Distribution management system wikipedia , lookup
Voltage regulator wikipedia , lookup
Buck converter wikipedia , lookup
Power electronics wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Stray voltage wikipedia , lookup
Surge protector wikipedia , lookup
Alternating current wikipedia , lookup
Appendix 2 Test Report for inverters larger than 16 A per. phase and up to and including 75 A per. phase, connected to the low voltage grid. Identifikation Inverter: Description: Manufactors name and adress Brand / Logo Phone / Fax E-mail Brand / model Nominal voltage Dok. 98992/12, Sag 10/405 Page 1 of 6 2.1 Voltage Quality Harmonic currents Harmonic limit for three-phase equipment with regards to EN 61000-3-12 Limit for individual harmonic current In/I1a [%] (Minimum short circuit current, Rsce = 33) Harmonic Limit I5 I7 I9 I11 I13 THD PWHD 10,7 7,2 3,8 3,1 2 13 22 Test value a) Details in EN 61000-3-12 Fast voltage changes and flicker Fast voltage changes and flicker with regards to EN 61000-3-11 Maximum voltage change % of nominel voltage at 100% power and flicker Limit Start Stop 3.3 % max 500 ms 3.3 % max 500 ms Running Pst = 1,0 Plt = 0,65 Test value 2.2 Coupling and syncronizing Can the system start and produce continuously within the normal production area only limited by protection settings mentioned below in 2.7 ? Does coupling and synchronization to the grid occur earlier than 3 min. after the voltage and frequency are back to normal? Does the active power production increase more than 10%. per minute after reset after fault? Is manual syncronization to the grid possible? Yes No Yes No Yes No Yes No Dok. 98992/12, Sag 10/405 Page 2 of 6 2.3 Asymmetry Does asymmetry of over 16A occur during normal operation and/or error? If the system consists of single-phase units, is it ensured that the above limit is not exceeded? Yes No Yes No 2.4 Regulation of active power Is the plant equipped with a down-regulation of the function of frequency, as shown below? Yes No 2.5 Regulation of reactive power Regulation of reactive power is by: Constant powerfactor cos φ Variable powerfactor cos φ (P) Changes in the active power results in modification of the reactive power? Dok. 98992/12, Sag 10/405 Yes No Page 3 of 6 2.5.1 Constant powerfactor Does the plant regulate in accordance with figure below? Yes No 2.5.2 Variable powerfactor Does the plant regulate in accordance with figure below? Yes No 2.6 Tolerances to voltage dips and voltage spikes Does the plant remain connected to the public grid during voltage changes, only limited by grid protection mentioned below in 2.7 “Grid protection”? Dok. 98992/12, Sag 10/405 Yes No Page 4 of 6 2.7 Grid protection Over- /under voltage Protection Symbol Setting Max time Over voltage (step 1) U> 1,10 x Un 40 s U>> 1,13 x Un 0,2 s U< 0,90 x Un 10 s Symbol Setting Max time f> 52,0 Hz 0,3 s f< 47,5 Hz 0,3 s Symbol Setting Max time df/dt +2,5 Hz/s 0,3 s df/dt -2,5 Hz/s 0,3 s Setting Test result Over voltage (step 2) Setting Test result Under voltage Setting Test result Over-/ under frequency Protection Over frequency Setting Test result Under frequency Setting Test result LoM test Protection "ROCOF" df/dt Setting Test result "ROCOF" df/dt Setting Test result Does the plant have central LoM protection? If Yes, are all consumers connected after LoM protection unit Dok. 98992/12, Sag 10/405 Yes No Yes No Page 5 of 6 Comments Test details Date for test Test Engineer name Test engineer signature Test laboratorium Dok. 98992/12, Sag 10/405 Page 6 of 6