Download cooper lighting - sure-lites

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Electric power system wikipedia , lookup

Rectifier wikipedia , lookup

Fault tolerance wikipedia , lookup

Decibel wikipedia , lookup

Electric battery wikipedia , lookup

Electrical substation wikipedia , lookup

Power engineering wikipedia , lookup

Electrification wikipedia , lookup

Buck converter wikipedia , lookup

Distribution management system wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Voltage optimisation wikipedia , lookup

Rechargeable battery wikipedia , lookup

Alternating current wikipedia , lookup

Switched-mode power supply wikipedia , lookup

History of electric power transmission wikipedia , lookup

Mains electricity wikipedia , lookup

Electrical ballast wikipedia , lookup

Opto-isolator wikipedia , lookup

LED lamp wikipedia , lookup

Street light wikipedia , lookup

Transcript
COOPER LIGHTING - SURE-LITES
DESCRIPTION
Catalog #
Type
The CC8 Contractor’s Choice FasTest™ High-Capacity Emergency
Lighting Unit is an affordable, yet attractive, alternative to standard
Project
two-headed emergency lighting units. All components snap together
to facilitate installation in 5 minutes or less. Field versatility is not
sacrificed for cost, as both lighting heads offer horizontal and vertical
Comments
adjustability. Moreover, proper operation of the transfer circuit and
emergency lamps can be quickly and safely verified by using a
Prepared by
convenient laser pointer (sold as an accessory).
The Model CC8 FasTest is ideal for applications that demand the
minimum cost but also require maximum flexibility, reliability and convenience in an attractive unit.
Date
S P E C I F I C AT I O N F E AT U R E S
Electronic
Dual-Voltage Input 120/277 VAC,
60 Hz
Designer-White Textured Finish
Glare-Free Lens
Fully Adjustable Lamp Housing
Line-Latching
Knockouts/Cutouts Provided in
Housing for Surface Conduit
Attachment
Solid-State Voltage
Limited Charger
Universal J-Box
Mounting Pattern
Solid-State Switching
Keyhole Mounting Slots
Low-Voltage Disconnect
Battery
Sealed Lead Calcium, Recombination
Brownout Circuit
Overload/Short Circuit
Protection
High-Impact Polycarbonate
Matches Housing Finish
Remote Capability,
76W Standard
Maintenance-Free, Long Life
Optional square and MR16 heads
available
Full Recharge Time, 24 hrs. (max.)
Push-Button Test Switch/Power
Indicator Light
Polarized Battery Terminals
Photocell Test Switch*
(requires accessory laser
for activation)
Code Compliance
UL 924 Listed
Metal and MR16 heads accept up to
50w lamps.
* Minor position adjustment of
photocell sensor may be required if
mounted in locations with high
ambient light
Life Safety NFPA 101
Push-In AC Power Connectors
Facilitate Installation
CSA Certified
Automatic 30-Sec. Test Upon Switch
Activation
NEC/OSHA
Housing Construction
Snap-Fit Component Design
Facilitates Under-5-Minute Installation
Warranty
Unit – 1 year
Housing Has (8) Locations for
Mounting of Heads; Consult Factory (3
optional bottom-mount and 3 optional
top- mount locations)
CC8 SERIES
Most State and Local Codes
SEALED LEAD
C A L C I U M B AT T E R Y
Battery – 5 year Pro-Rata
Reinforcing Ribs Throughout to
Provide Maximum Strength
F a s Te s t E m e r g e n c y
Lighting Unit
Head/Lamp Data
Two 12W, 12V Heads Standard
Injection-Molded, Color-Stable, HighImpact UL 94-5V Rated Polycarbonate
Housing and Mounting Plate
New Head Design Accepts Almost Any
Lamp
Verify proper operation of the
transfer circuit and emergency
lamps with convenient laser
pointer (sold as an accessory).
Emergency Lighting
E N E R G Y D AT A
Charge Mode
(Fully Discharged Battery)
Input Power:
120V=28W
277V=28W
Input Current (Max.):
120V=.26A
277V=.11A
E L E C T R I C A L R AT I N G S
R a t e d W a t t a g e to 87 1/2% of Rated D.C. Voltage
Model
DC Voltage
1 1/2 Hours
4 Hours
CC8
12
100
50
CC8MRT
12
100
50
Lamp Information
Type
Wattage
Number
Incandescent
MR16
12W ea
12W ea
029-132
029-141
Spacing
(1)
24'
50'
Power Factor:
120V=>.91
277V=>.91
T.H.D.:
120V=<35%
277V=<39%
O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: CC8MRT2142SM
CC8
Model Number
CC8
(1)
O p t i o n s (add as suffix)
SQ=Square Head (12W Standard)
Other lamp wattages available.
Consult Cooper Lighting Representative.
MRT=MR16 Heads (12W Standard)
Other lamp wattages available.
ConsultCooperLightingRepresentative
A=Ammeter
V=Voltmeter
TDM- Time Daily Meter
A c c e s s o r i e s (order separately)
Cord Set= CSK120, CSK277
Laser=Key Chain, Red Laser Pointer
SM=Side Mount Heads
(activation tested at 30 feet)
TM=Top Mount Heads
VS1=Polycarbonate Vandal Shield
BM=Bottom Mount Heads
VS1WP=Polycarbonate Vandal Shield
Alternate Lamps, Head Types,
Weather Resistant
No Head, Multiple Heads Consult Cooper Lighting Representative WG3=Wire Guard
2MS=Mounting Shelf (Specify Color)
Other Options: Consult Cooper
Lighting Representative
The "Rule of Thumb" spacing guidelines are designed to achieve 1 foot-candle average and 0.1 foot-candle minimum with a 40:1 maximum/minimum
ratio. The corridor used is 100 feet long, 9 feet ceiling with a 6 feet wide walkway and 3 feet path of egress. The reflectances are 80% ceiling, 50% walls
and 20% floors. The fixture mounting height is 7.0 feet with a lamp head angle of 45 degrees. Cooper Lighting assumes no responsibility for local
requirements or specific project variables. This is a guideline to be used as a design aid, not as guarantee of any code compliance.
COOPER LIGHTING
Standby Mode
(Fully Charged Battery)
Input Power:
120V=4.1W
277V=4.0W
Input Current (Max.):
120V=.07A
277V=.03A
Power Factor:
120V=>.50
277V=>.50
T.H.D.:
120V=<94%
277V=<99%
(Supersedes ADX031196) ADX041146
®
C C 8 SERIES
PHOTOMETRICS
029-132
24' Spacing
Illuminance Values(Fc)
Average=3.09
Maximum =14.6
Minimum =0.4
Avg/Min Ratio=7.73
Max/Min Ratio=8.33
Max/Min Ratio=36.50
Illuminance Values(Fc)
Average=0.84
Maximum =5.8
Minimum =0.1
Avg/Min Ratio=8.40
Max/Min Ratio=58.00
For Standard Fixture: CC8***
029-141
50' Spacing
For Standard Fixture: CC8MRT***
*** The "Rule of Thumb" spacing guidelines are designed to achieve 1 foot-candle average and 0.1 foot-candle minimum with a 40:1 maximum/minimum ratio. The corridor used is 100 feet long, 9
feet ceiling with a 6 feet wide walkway and 3 feet path of egress. The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture mounting height is 7.0 feet with a lamp head angle of 45
degrees. Cooper Lighting assumes no responsibility for local requirements or specific project variables. This is a guideline to be used as a design aid, not as guarantee of any code compliance.
T E C H N I C A L D AT A
Lamps
Solid-State Charger
S o l i d - S t a t e Tr a n s f e r
P h o t o c e l l Te s t S w i t c h
Designed specifically for emergency
lighting applications, the PAR 36 12V
sealed-beam type design insures
optimum glare-free trapezoidal light
distribution along with horizontal
and vertical adjustment by rotating
the lens within the housing.
Supplied with a 120/277 VAC,
voltage regulated solid-state
charger. Immediately upon
restoration of AC current after
a power failure, the charger
provides a high charge rate. The
charge circuit reacts to the condition
of the battery and alters the rate of
charge in order to maintain peak
battery capacity and maximize
battery life. Solid-state construction
recharges the battery following a
power failure in accordance with
UL 924.
The unit incorporates a solid-state
switching transistor which
eliminates corroded and pitted
contacts or mechanical failures
associated with relays. The
switching circuit is designed to
detect a loss of AC voltage and
automatically energizes the lamps.
Upon restoration of the AC power,
the emergency lamps will switch off
and the charger will automatically
recharge the battery.
Allows verification of proper
operation of the transfer circuit and
emergency lamps with a laser
pointer (laser is sold as an
accessory). The emergency lamps
will test for 30 seconds when
activated.*
Housing
The subtly detailed Model CC8
housing is constructed of flameretardant and impact-resistant
polycarbonate in a color-stable
designer-white finish. All electrical
components are securely attached in
the housing and prewired for fast AC
connection. The housing snaps on to
the hinged mounting plate with two
integral locking tabs. The mounting
plate has keyhole mounting slots and
a universal mounting pattern for
quick, efficient installation.The
housing contains knockouts/cutouts
for surface conduit attachment. All
structural components are designed
with reinforcing ribs to add additional
rigidity and to maximize structural
integrity.
Overload and Short
Circuit Protection
The solid-state overload monitoring
device in the DC circuit disconnects
the lamp load from the battery
should excessive wattage demands
be made and automatically resets
when the overload or short circuit is
removed. This overload current
protective feature eliminates the
need for fuses or circuit breakers
for the DC load.
Brownout Circuit
Line-Latched
Sure-Lites’ line-latched electronic
circuitry makes installation easy and
economical. A labor efficient ACactivated load switch prevents the
lamps from turning on during
installation to a non-energized AC
circuit. Line-latching eliminates the
need for a contractor’s return to a job
site to connect the batteries when the
building’s main power is permanently
turned on.
The brownout circuit in Sure-Lites
units monitors the flow of AC
current to the unit and activates the
emergency lighting system when a
predetermined reduction of AC
power occurs. This dip in voltage
will cause most ballasted fixtures to
extinguish causing loss of normal
lighting even though a total power
failure has not occurred.
L o w - Vo l t a g e D i s c o n n e c t
When the battery’s terminal voltage
falls below 80% of the rated voltage,
the low voltage circuitry disconnects
the lighting load. The disconnect
remains in effect until normal utility
power is restored, preventing deep
battery discharge.
Te s t S w i t c h / P o w e r I n d i c a t o r
Light
Conveniently located combination
Test Switch/Power Indicator Light
allows for manual verification of
proper operation of the transfer
circuit and emergency lamps. The
emergency lamps will test for 30
seconds when activated.
Sealed Lead-Calcium
Battery
The fully sealed, long life,
maintenance-free lead-calcium
battery is ideal for emergency
lighting applications. These
recombinant cycle batteries typically
provide eight to ten years of life and
may be operated in any position.
Warranty
All Sure-Lites units are backed by a
firm one year warranty against
defect in material and workmanship
(excluding lamps). Maintenancefree, long life, sealed lead calcium
batteries carry a five-year
Pro-Rata warranty.
* Minor position adjustment of
photocell sensor may be required if
mounted in locations with high
ambient light.
N O T E S : See options/accessories or technical sections for additional detailed product data. Specifications and Dimensions subject to change without notice.
Customer First Center 1121 Highway 74 South, Peachtree City, GA 30269 770.486.4800 Fax 770.486.4801 ADX041146