AY-L23 and SA-23-B2/B4
Outdoor Long-Range RF Reader and Remote Controls
Installation and Operation Manual
1. Introduction
Figure 1: AY-L23 and SA-23-B2/B4
The AY-L23 is an outdoor long-range RF reader that acts as a receiver.
It is compatible with Rosslare’s SA-23 wireless remote control
transmitters:

SA-23-B2 – 2-Button Remote Control

SA-23-B4 – 4-Button Remote Control
The AY-L23 reader and the remote controls are available in both G
(433.92 MHz) and H (868.35 MHz) frequencies.
The AY-L23 is not compatible with old remote controls such as:
SA-26, SA-27, and SA-28.
When the AY-L23 receives the a command signal from a SA-23-B2/B4
wireless transmitter, the AY-L23 outputs the ID to A_DATA0,A_DATA1
or B_DATA0,B_DATA1 to the attached controller and controls the
function of the relay (open drain FET) A or B according to the SA-23-B2
remote’s command.
The command signal consists of 3 parts:

ID (in Wiegand format)

ID output to A or B Wiegand Output according to the command in
SA-23-B2

Relay Function A or B according to command in the SA-23-B2
AY-L23
SA-23-B2
SA-23-B4
2. Technical Specifications
2.1
AY-L23
2.2
SA-23-B2/B4
Input Voltage
7 to 24 VDC
Input Voltage
3 V Battery (CR 2450)
Standby Current
26 mA (12 VDC)
Standby Current
< 1 uA
Maximum Operating Current
65 mA (12 VDC)
Max Operation Current
10 mA
Relay (FET, Open Drain) Current 200 mA (max voltage 40 V)
ID Format
Programmed to Wiegand 26-Bit
Tamper Output
Open collector, active Open, max. sink
current is 16 mA
Frequencies
Maximum Cable Distance to
Controller
152 m (500 ft.)
G: 433.92 MHz (ASK)
H: 868.35 MHz (ASK)
Operating Temp. Range
-31°C to 63°C (-25°F to 145°F)
Wiegand Output Format
Wiegand 26-Bit, 32-Bit, 34-Bit, 40-Bit
(decided by remote)
Operating Humidity
0 to 95% (non-condensing)
Dimensions (L x W x D)
58 x 41 x 13.4 mm (2.3 x 1.6 x 0.5 in.)
Frequencies
G: 433.92 MHz
H: 868.35 MHz
Weight
AY-L23: 100.8 g (3.56 oz)
SA-23: 21 g (0.74 oz) (without battery)
Operating Temperature Range
-31°C to 63°C (-25°F to 145°F)
Operating Humidity Range
0 to 95% (non-condensing)
Suitable for outdoor use (IP65)
Dimensions (L x W x D)
145 x 43 x 20 mm (5.7 x 1.7 x 0.8 in.)
3. Mounting Instructions
Determine an appropriate mounting position for the receiver. Do not
mount the receiver near any source of wireless interference or on any
metal surface.
To mount the receiv er:
1. Peel off the back of the self-stick mounting label template included
with the unit and place at the desired mounting position.
2. Using the template as a guide, drill two holes (hole size is indicated
on mounting template) for mounting the receiver to the surface.
3. Drill a 7/16” (10-mm) hole for the cable.
4. Remove the front case from the receiver.
5. Attach the receiver to the controller. (See wiring instructions)
6. Screw the receiver’s rear case onto its mounting location and
return the front case onto the mounted rear case.
The receiver is to be used with control panels whose power supply is
UL Listed Class 2 or equivalent.
1
4. Wiring Instructions
To connect the receiv er to the controller:
Table 1: Wiring
1. Prepare the receiver cable by cutting the cable jacket back 1¼
inches and strip the wires ½ inch.
Color
2. Prepare the controller cable by cutting the cable jacket back 1¼
inches and strip the wires ½ inch.
3. Splice the receiver’s pigtail wires to the corresponding controller
wires and cover each connection (see Table 1).
Functionality
Red
VIN (7–24 VDC)
Black
GND
Dark Green
A_Data0
White
A_Data1
Orange
A_LEDCTL (green LED)
•
The individual wires coming out of the receiver are color coded
according to the recommended Wiegand standard.
Blue
A-OUTPUT (FET, Open Drain)
•
When using a separate power supply for the receiver, this supply and
the controller’s power supply must have a common ground.
Light Green
B-DATA0
Gray
B-DATA1
•
The cable shield wire on the receiver should be attached to an Earth
ground (best) or signal ground connection at the panel or power
supply end of the cable. This configuration is best for shielding the
receiver cable from external interference.
Brown
B_LEDCTL (orange LED)
Yellow
B-OUTPUT (FET, Open Drain)
Purple
TAMPER
5. Operation
4B
The AY-L23 works with any SA-23 remote and can operate two
Wiegand data outputs connected to the reader’s inputs at the access
control panel.
5.3
Registering an ID
10B
The AY-L23 can register up to 48 IDs with an SA-23-B2/B4.
To register an ID:
The AY-L23 LED is red in Operation mode.
1. Connect the orange and brown wires to GND.
2. Power on at Vin and GND.
5.1
Reader Mode
After buzzer sounds 3 times, the LED turns green.
8B
The AY-L23 is now in Register mode for 15 seconds.
When pressing 1 on the SA-23-B2/B4, the AY-L23 sends Wiegand
data-A. The LED changes to green for a short time with a beep.
3. Press 1 on the SA-23-B2/B4 remote.
When pressing 2 on the SA-23-B2, the AY-L23 sends Wiegand data-B.
The LED changes to orange for a short time with a beep.


If the ID was previously registered, you hear 2 long beeps.
When pressing 2 on the SA-23-B4, the AY-L23 sends ID+1 on Data A
line to the controller. The LED changes to green for a short time with a
beep.

If the limit of IDs (48) is reached, you hear have 3 long beeps.
5.2
If the registration is successful, you hear 2 short beeps.
4. Press 2 on the SA-23-B2/B4 remote.

Controller and Reader Mode
If the registration is successful, you hear 2 short beeps.

If the ID was previously registered, you hear 2 long beeps.
The AY-L23 can operate two OC outputs A/B with the SA-23-B2.

If the limit of IDs (48) is reached, you hear have 3 long beeps.
To activate the output from SA-23-B2, the remote button’s ID should
be registered first (Section 5.3).
Once the AY-L23 exits Register mode (after 15 seconds), you hear
a long beep.
9B
For the SA-23-B4 remote, follow the same procedure to
register Buttons 3 and 4 to the AY-L23.
In Controller and Reader mode, SA-23-B4 is not in use as it
does not activate any output of the AY-L23.
When pressing 1 on the SA-23-B2, the AY-L23 sends Wiegand data-A
and activates out-A for 5 seconds.
5.4
When pressing 2 on the SA-23-B2, the AY-L23 sends Wiegand data-B
and activates out-B for 5 seconds.
To delete all IDs:
Deleting all IDs
1B
1. Connect the orange wire to GND.
2. Power on at Vin and GND.
After buzzer sounds 3 times, the LED turns orange for 2 seconds
and then turns green.
The AY-L23 is now in Delete mode for 5 seconds.
3. When the LED turns green, disconnect the orange wire from GND.
The LED changes from green to orange.
4. Re-connect the orange wire to GND within 5 seconds.

If all the IDs in reader are deleted successfully, the alarm
sounds 2 times and then you hear 3 short beeps.

If the deletions fails (times out), the reader outputs a long
beep.
6. Using the SA-23
5B
The AY-L23 is used along with either the SA-23 2-button or 4-button
remote control.
The SA-23-B4 remote is programmed to:

The SA-23-B2 remote is programmed to:
Button 1 – Wiegand output to A DATA0/1 [ID number]

Button 2 – Wiegand output to A DATA0/1 [ID number+1]

Button 1 – Wiegand output to A DATA0/1 with A FET(relay)ON 5S

Button 2 – Wiegand output to B DATA0/1 with B FET(relay)ON 5S
Button 3 – Wiegand output to A DATA0/1 [ID number+2]


Button 4 – Wiegand output to A DATA0/1 [ID number+3]
2
6.1
6.3
Initial Setup
To set up the remote for use:
You can set Button 2 to transmit the same ID as Button 1 or to
transmit a unique ID. By default, Buttons 1 and 2 transmit the same ID
number.
1. Install the battery.
The red LED turns on for 1 second, turns off 1 second and then
turns on for 1 second.
To change the ID of Button 2 to be unique:
2. Check the distance range of the remote:

If the distance is set to long range (70 m), LED flashes on and
off 0.5 seconds 3 times.

If the distance is set to short range (15 m), LED flashes on and
off 0.1 seconds 6 times.
Changing the ID of Button 2 (for SA23B2 only)
1. Remove the battery from the remote.
2. Press any button to reset the remote.
3. Press 2 and install the battery until the red LED flashes quickly 5
times for 0.1 seconds.
Button 2 will now use transmit a unique ID (ID of Button 1 +1)
By default, the remote distance is set to 70 m.
4. Close the cover.
To change the ID of Button 2 to use ID of Button 1:
6.2
1. Remove the battery from the remote.
Changing the Remote Distance Range
2. Press any button to reset the remote.
You can set the remote range to either 15 or 70 m.
3. Press 1 and install the battery until the red LED flashes quickly 5
times for 0.1 seconds.
To set the remote distance:
Button 2 will now transmit the same ID as Button 1.
1. Remove the battery from the remote.
4. Close the cover.
2. Press any button to reset the remote.
Any time you remove the battery from the SA-23, you must reset
the remote control by pressing any key to discharge the internal
capacitors.
3. Install the battery.
4. Press 1 and 2 together before the LED flashes for a second time.
The remote toggles to the other remote distance range.

If the distance is set to long range (70 m), LED flashes on and
off 0.5 seconds 3 times.

If the distance is set to short range (15 m), LED flashes on and
off 0.1 seconds 6 times.
3
Declaration of Conformity
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:

This device may not cause harmful interference.

This device must accept any interference received, including
interference that may cause undesired operation.
This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate
the equipment.
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation.

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.
Limited Warranty
The full ROSSLARE Limited Warranty Statement is available in the Quick
Links section on the ROSSLARE website at www.rosslaresecurity.com.
Rosslare considers any use of this product as agreement to the
Warranty Terms even if you do not review them.
Contact Information
United States and Canada
China
Rosslare Security Products, Inc.
Southlake, TX, USA
Toll Free: +1-866-632-1101
Local:
+1-817-305-0006
Fax:
+1-817-305-0069
[email protected]
Rosslare Electronics (Shenzhen) Ltd.
Shenzhen, China
Tel: +86-755-8610-6842
Fax: +86-755-8610-6101
[email protected]
Europe
Rosslare Enterprises Ltd.
Kowloon Bay, Hong Kong
Tel: +852-2795-5630
Fax: +852-2795-1508
[email protected]
Asia Pacific, Middle East, Africa
Rosslare Israel Ltd.
Rosh HaAyin, Israel
Tel: +972-3-938-6838
Fax: +972-3-938-6830
[email protected]
India
Latin America
www.rosslaresecurity.com
4
0706-0960503+03
Rosslare Electronics India Pvt Ltd.
Tel/Fax: +91-20-40147830
Mobile: +91-9975768824
[email protected]
Rosslare Latin America
Buenos Aires, Argentina
Tel: +54-11-4001-3104
[email protected]