Download SONOVISION

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Alternating current wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Voltage optimisation wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Rectifier wikipedia , lookup

Heterodyne wikipedia , lookup

Stepper motor wikipedia , lookup

Chirp compression wikipedia , lookup

Chirp spectrum wikipedia , lookup

Spirit DataCine wikipedia , lookup

Mains electricity wikipedia , lookup

Opto-isolator wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Rotary encoder wikipedia , lookup

Radar signal characteristics wikipedia , lookup

Transcript
SONOVISION
Sonovision is a ruggedised, portable ultrasonic inspection system capable of simultaneous
multi-channel Time-of-Flight-Diffraction (TOFD) and Pulse Echo (PE) Corrosion/Erosion
Mapping capable of interfacing to a wide range of single/multi-axis manipulators including
video tracking. The system comes complete with a suite of comprehensive data collection
and off-line analysis software that runs under Windows 95/98/ME/NT/2000/XP.
Key Features
•
•
•
•
•
•
•
•
•
•
•
•
•
One box complete system contained in an portable,
ruggedised laptop
1, 2, 4, 8 or 16 channel variants available
Integrated single card solution containing entire
ultrasonic pulser/receiver/digitiser & DSP
Real time RF, A, B, C, D-scan displays and storage
Multi-channel, simultaneous TOFD and Pulse Echo
Corrosion/Erosion Mapping
Position stamping from up to 2 encoders
Corrosion Mapping using Video Tracking technique
Comprehensive configuration, data acquisition, offline analysis and reporting software
Windows 95/98/ME/NT/2000/XP Operating System
Expandable up to 256 channels by daisy-chaining
additional cards
External or internal motor drive option
Battery operation for 2-4 or 6-8 with extended
battery option
Continuous hardware/software updates &
improvements
Sonovision - One-box, ruggedised TOFD & PE System
PC specification
General
Physical
CPU
Pentium Centrino 1.4 / 1.6 GHz
External Dimension
310W x 254D x 121H mm
(12.2” x 10.0” x 4.7”)
Memory
512 MB DDR
Weight
6.5 kg (14 lb)
Hard Drive
40 GB
Temperature Range
0°C to 50°C
Display
14.1” XGA (1024x768) daylight
readable TFT (upgradeable)
Interfaces
2 x RS232 (optional RS422/RS485),
EPP/ECP Parallel, 2 x USB, 10/100
Ethernet
Input Voltage
100-240 VAC (10-20V DC optional)
Storage
1.44 MB floppy, CD-ROM (RW
optional)
Battery
2-4 operational (6-8 with extended battery
option)
(upgradeable)
(upgradeable)
Power
Where to find Sonovation Products and Systems
Krombraak 13
4906 CR Oosterhout
The Netherlands
Tel. +31 (0)162 425588
Fax: +31 (0)162 424343
PO Box 112
Lymm
WA13 9XZ Cheshire, United Kingdom
Website: www.Sonovation.com
E-mail: [email protected]
© Sonovation®
SONOVISION
Typical TOFD analysis display with FFT
Sealed NEMA12 / IP54 rated enclosure
Simultaneous TOFD & Corrosion Mapping
Technical Specification
Pulser / Receiver
Digitiser
Probe Connectors
1, 4, 8 or 16 (expandable up to 128)
Software Channels
Up to 256
Sampling Rate
125MHz to 2MHz in 7 steps
(250MHz optional)
Transducer Type
HT Pulse Voltage
Single or Twin
Resolution
8-bit
-40 V to –300 V in 2V increments
(Higher voltages optional)
Points per channel
Sample Delay
65536 (256k optional)
0 to 10ms dependent upon
digitisation frequency.
HT Pulse Width
15 ns to 1000 ns in 5 ns increments
(with <10 ns rise time)
PRF
10 Hz to 20 kHz in 10 Hz steps
(dependant upon voltage, pulse
width and gate settings)
Averaging
Averaging Performance
2 to 256 frames or disabled
Real-time hardware averaging of all
channels at maximum digitisation
rate
128k – dynamically allocated across
channels
Averaging Memory
Amplifier
Gain Range
-10 dB to +110 dB in 0.1 dB steps
Bandwidth
0.5 - 40 MHz
Input Noise Level
1.5nV/(Hz)
Impedance (Damping)
133Ω
1/2
Max. Gates per Channel
16 – start, length and threshold
specified in mm or µs
Peak Detection
Real-time hardware peak detection:
First ‘n’, Last ‘n’, Largest ‘n’
amplitude
Transfer Rate to PC
133MB/s PCI Burst Mode
(other options available)
Distance Amplitude Correction (DAC)
(10/12 bit optional)
Encoder Interface
Gain Range
-10 dB to +110 dB in 0.1 dB steps
DAC Curves
8
Number of Axes
2 (4 optional)
16kByte
Encoder Type
Single (Differential optional)
DAC Points per Curve
Up to 4096. Optimum number is
automatically selected depending on
channels, frequency & range.
Encoder Voltage
Encoder Counts
5V (TTL)
Input Frequency
1MHz
DAC Frequency
¼ to 1/32 of digitisation rate
automatically selected depending on
range & points
Video Tracking Interface
DAC Memory
DAC Reference
TX pulse or Interface Echo
Signal Filtering & Rectification
±231 quadrature counts
Maximum Image Size
Detection speed
768 x 576 (PAL)
50 Hz (PAL)
Standard
PAL or NTSC
Low Pass Filters
1.3MHz, 3MHz, 5.5MHz, 7.6MHz,
10.3MHz, 13.3MHz, 22MHz &
Broadband (channel selectable)
Motor Drive Unit Interface
High Pass Filters
0.5MHz, 1.5MHz, 3MHz, 4MHz,
6.1MHz, 7.5MHz, 12.5MHz,
16.5MHz. (channel selectable)
Digital - Full-wave, Positive halfwave, Negative half-wave and RF
selectable on a channel basis.
Description
External 2 axis DC motor controller
and driver (optional)
Interface Type
RS232/485
Link Speed
115 kbps
Rectifier
Post-Rectification Filters
Digital
© Sonovation®