Download (HVDC) Power Lines
Three-phase electric power wikipedia , lookup
Electromagnetic compatibility wikipedia , lookup
Opto-isolator wikipedia , lookup
Buck converter wikipedia , lookup
Electric power system wikipedia , lookup
War of the currents wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Electric machine wikipedia , lookup
Voltage optimisation wikipedia , lookup
Stray voltage wikipedia , lookup
Surge protector wikipedia , lookup
Vehicle-to-grid wikipedia , lookup
Wireless power transfer wikipedia , lookup
Electrical substation wikipedia , lookup
General Electric wikipedia , lookup
Overhead power line wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Electric power transmission wikipedia , lookup
Transmission tower wikipedia , lookup
Distributed generation wikipedia , lookup
Electrification wikipedia , lookup
Life-cycle greenhouse-gas emissions of energy sources wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Rectiverter wikipedia , lookup
Mains electricity wikipedia , lookup
HVDC converter wikipedia , lookup
Power engineering wikipedia , lookup
High-voltage direct current wikipedia , lookup
Strahlenschutzkommission Geschäftsstelle der Strahlenschutzkommission Postfach 12 06 29 D-53048 Bonn http://www.ssk.de Biological Effects of Emissions from High Voltage Direct Current (HVDC) Power Lines Recommendation by the German Commission on Radiological Protection, with scientific reasoning – Excerpt – Adopted at the 263rd meeting of the German Commission on Radiological Protection, on 12 September 2013 Biological Effects of Emissions from High Voltage Direct Current (HVDC) Transmission Lines 2 Introduction The governmentally encouraged use of renewable energy sources as a result of the transformation of the energy system (energy turnaround - Energiewende) in Germany leads to long distances between the points at which electric power is generated and consumed. This presents a need to build new long-distance power transmission lines. High voltage direct current (HVDC) power lines are to be employed as a part of this grid expansion. The Federal Ministry for the Environment, Nature Conservation and Nuclear Safety (BMU) requested the Commission on Radiological Protection (SSK) to supplement its previous statement on alternating voltage energy supply systems (SSK 2008) by providing an assessment of HVDC lines, especially of their constant electric and magnetic fields, in terms of radiation protection aspects with regard to human exposure. The SSK subsequently prepared the following recommendation. Deriving limit values is not a subject of this recommendation. Recommendations In view of the anticipated ambient levels of electric and magnetic fields generated by HVDC overhead power lines, and considering the prevailing regulatory gaps, the SSK makes the following recommendations: The SSK recommends that the constant electric fields of HVDC lines be limited with the goal of preventing health impairment or substantial discomfort, and that a weighted summation of the individual contributions be conducted in cases of simultaneous exposure to constant and alternating electric fields. Due to the limited data, notably with regard to the numbers of persons studied and the influences of cofactors such as ion density, it is not possible at present to derive reliable threshold values for perception, discomfort, pain and danger. The SSK therefore recommends that further research be conducted on perception, mainly in the form of human studies under well-controlled conditions. The SSK recommends that grid operators be requested to prevent possible secondary effects (such as electric shocks caused by discharges to or from conductive surfaces) by taking suitable corrective action, primarily with a focus on constructive measures. The SSK notes the need to protect individuals who carry magnetically activatable implants. For instance, in order to definitely ensure that no interference with cardiac pacemakers occurs, the SSK recommends that the magnetic flux density be limited to 500 µT.