Download fire detection systems fire detection systems

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Stray voltage wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Fault tolerance wikipedia , lookup

Control theory wikipedia , lookup

Rectifier wikipedia , lookup

Islanding wikipedia , lookup

Mains electricity wikipedia , lookup

Fire-control system wikipedia , lookup

Power electronics wikipedia , lookup

Wien bridge oscillator wikipedia , lookup

Buck converter wikipedia , lookup

Control system wikipedia , lookup

Alternating current wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Ground loop (electricity) wikipedia , lookup

Opto-isolator wikipedia , lookup

Earthing system wikipedia , lookup

Solar micro-inverter wikipedia , lookup

Transcript
FIRE DETECTION
SYSTEMS
Product catalogue
JUNO-SYS
One loop analogue addressable control panel
FUNCTIONAL CHARACTERISTICS
Single loop panel - Non expandable
Smaller Size: Junior 314x320x80
Supports connection to Mini-repeater via RS485 and/or fibre-Optic interfaces
125 device addresses
96 VULCAN (addressable) ultra low current base sounders (32 address limit)
32 individually programmable sounder addresses
Full SAM (Self Addressable Module) support
2 Fire output relays (change-over) and 1 Fault relay (change-over)
2 conventional alarm outputs (Individually programmable)
All detector loops monitored for integrity
384 fully programmable zones
512 fully programmable sounder groups
Event log (rolling, 2000 entries)
Compatible with Apollo S90 /XP95T and DiscoveryT Protocols
Compatible with all our own low cost ancillary modules
Backlit LCD display with 4 rows of 40 characters
Programming by integrated keypad
Multiple language support (menu selectable)
Optional fire and fault LED zone indication
Integrated 8 zone LED fire zone indication
Interactive DiscoveryT functions
Pr.Id.:30103
2
RAIK-1
ANALOGUE ADDRESSABLE CONTROL PANEL
RAIK
Pr.Id.:30100
1-3 loops analogue addressable control panel
RAIK-1 is an analogue addressable control panel with
modular 1-3 loop configuration with 32 zones. Main unit is
composed from RAIK A and B modules. Analogue loops are
created with modules RAIK-M . See accessories bellow
CHARACTERISTICS
under UNI EN54-2 and UNI
EN54-4 , power supply 2A/24Vdc
DETECTOR INPUTS
- max 378 analog detectors on 3
(6) loops
- max 248 conventional local or
remote lines (loop RS485)
- 32 zone
ALARM OUTPUTS
- alarm output with indication of short
circuit
PROGRAM OUTPUTS
- max 6 outputs el. programed
- max 64 outputs programmed on 8 channel
adapters, local or remote
- alarm and trouble output N.O./ N.C.
SERVICE PORTS
- connection with a PC trough RS-232/485
- serial clock/date output
- local bus SPI for connection with I/O adapters
EVENT BUFFER
Internal buffer for 800 evens, possible to download to a PC or
print to RS232
ACCESSORIES
PGD
Remote LCD indication keyboard
Pr.Id.:31103
RAIK-M
Pr.Id.:31100
RAIK-U
Analogue addressable loop card for
expansion of loop with 126 address or
2 loops of 63 address
Input module with 8 inputs
Pr.Id.:31101
RAIK-I
Output module with 8 relay outputs
Pr.Id.:30102
3
JUNO NET
Analogue addressable network control panel
FUNCTIONAL CHARACTERISTICS
Fully expandable system - from 1 to 96 loops
125 device addresses per loop
96 VULCAN (addressable) ultra low current base sounders per loop
32 individually programmable sounder addresses per loop
2 Fire output relays (change-over)
Open collector outputs for Fire, Fault and Pre-alarm remote indicators
2 conventional alarm outputs on each Main Panel and Sub-panel
Repeaters with optional Integrated Sub-panels
All detector loops monitored for integrity
384 fully programmable zones
512 fully programmable sounder groups
1 TO 3 LOOPS
Event log (rolling, 2000 entries)
Compatible with Apollo S90/XP95 and Discovery Protocols
Compatible with all our own low cost ancillary modules
Backlit LCD display with 4 rows of 40 characters
Programming by infra-red remote keypad, PC keyboard and Windows™ based‘Loader’ software
Windows™ based PC graphics software for alarm management and reporting
Multiple language support (menu selectable)
BMS output (RS232)
Evacuate/Class Change input
Multi-panel network by RS485 or fibre optic links
Optional internal 40 column thermal printer
Optional fire and fault LED zone indication
ELECTRICAL & MECHANICAL CHARACTERISTICS
Primary supply voltage
Secondary supply voltage
Power supply rating
Sounder output rating
Auxiliary output rating
Battery fuse rating
Auxiliary contact rating
Quiescent current w/out devices
Box *
Cable entries
Dimensions (1-3 loops box)
Dimensions (1-12 loops box)
Dimensions (sub-panel box)
Dimensions (mini-repeater box)
Battery Capacity
Weight
85-265V AC 50/60Hz
24V DC nominal
60W or 150W output
1 Amp
1 Amp fused
3 Amp
1A 50V AC/DC
130 mA
1.5mm aluminum or mild steel coated white
Back through cut out/top by 6 removable plugs
H: 370 W: 340 D: 127 (mm)
H: 420 W: 550 D: 127 (mm)
H: 370 W: 340 D: 127 (mm)
TBA
Up to 2 x 12V 12A/H
6.5 Kg
4
JUNO NET
Analogue addressable network control panel
1, 3
LOOP Juno-NET 100
4-12
Pr.Id.:30109
LOOPS Juno-NET 400
5
Juno-NET300
Pr.Id.:30105
Pr.Id.:30104
JUNO NET
Analogue addressable network control panel
REP
Pr.Id.:30114
REPEATER WITH OR WITHOUT INTEGRATED SUB-PANEL
The JUNO-NET repeater has an identical appearance to the JUNO-NET main panel and has similar
electrical characteristics. It allows full control and programming of the entire fire protection system as if
you were at the main panel. A repeater with integrated sub-panel allows a distributed system topology
ideal for multiple building networks where display and control is necessary in each building. Each
integrated sub-panel has its own unique (programmable) address and can have either one or three
detection loops. From the user perspective the only difference between a repeater and the main panel is
that a repeater cannot support a printer.
SUB-PANEL
Pr.Id.:30108
Whenever a fire alarm system grows beyond 3 loops in terms of either
detection points or topology, it is possible to add sub-panels in
increments of 3 loops and supplied in fully closed cabinets, provided
with independent primary and secondary power supplies. In each
cabinet it is possible to install 1, 2 or 3 sub-panel boards with each
board containing 3 loops, hence the 1-9 loops capability. The power
supply is 5.4A PSU/Charger. Only one RS-422/485 or Fibre-optic
interface is needed in each cabinet to provide the communication
path to the rest of the system. These cabinets can be installed closer
to the fire monitoring devices, enabling significant savings in
expensive fire-proof cabling
REP-Mini
Pr.Id.:30113
This sleek, unobtrusive repeater panel can be used to control any
distributed, or self-contained JUNO-NET based fire alarm system.
Because of its reduced dimensions it is especially recommended for
front desk monitoring of large systems where it would be impractical to
place a full size control panel in a cluttered reception booth. Up to 10
repeaters can be connected to a main JUNO-NET fire alarm panel, all
of which offer full control over the system. Connection to the JUNONET is via its data-loop communication bus and can be through an RS422/485 or Fibre-optic interface. Compatible with Juno-SYS.
6
JUNO NET ACCESSORIES
Analogue addressable network control panel
J-NET-LOOPCON
LOOP CONNECTOR
Pr.Id.:30118
CHARACTERISTICS
DIMENSIONS: FACE PLATE 76 x 76 x 2 (mm)
DIMENSIONS: INDICATOR: 68 x 33 x 25 (mm)
This interface board provides a separate area for connecting the addressable
loops wiring. It also has the entry level filtering to reduce overall noise
susceptibility of the JUNO-NET panel ( needed if REP + loop card are used)
Loop card-1 Pr.Id.:30106 & Loop card-3
LOOPCARD - SINGLE AND THREE LOOPS
Pr.Id.:30107
CHARACTERISTICS
DIMENSIONS: FACE PLATE 76 x 76 x 2 (mm)
DIMENSIONS: INDICATOR: 68 x 33 x 25 (mm)
These are the work-horses of our range of panels. Since their creation in 1992 they have been improved in
many respects, reaching today an unparalleled performance in their function of interfacing the real world of
the loop wiring and devices, with the sensitive electronics of an advanced fire alarm control panel.
SUB-PANEL
SUB-PANEL BOARD
Pr.Id.:30108
CHARACTERISTICS
DIMENSIONS: FACE PLATE 76 x 76 x 2 (mm)
DIMENSIONS: INDICATOR: 68 x 33 x 25 (mm)
The sub-panel board is in essence a building block of a
JUNO-NET control panel, either in a distributed or self
contained topology.
Capable of managing up to 3 loops of analogue
addressable devices, it will operate on its own even in the
event of lack of communication with the JUNO-NET main
panel, detecting fire and fault situations and activating its
own loop sounders, I/O units etc.
This unit is also the processor board for the JUNO-NET
Mini-Repeater as well as our low-costing single loop
panel named JUNiOr. JUNiOr will be out towards end of
2003.
Printer
INTERNAL PRINTER
Pr.Id.:30110
CHARACTERISTICS
WEIGHT:
DIMENSIONS:
208 grams (including paper roll)
H: 65 W: 145 D: 45 (mm)
This 40 column internally mounted thermal printer provides a log
of all the relevant events occurring in the JUNO-NET system. All
events are date and time stamped and are backed up by the 2000
events deep rolling log kept in the panel processing unit.
NOTE: In order for the printer to work properly it is necessary that
the J-NET-QUART chip (pictured) be installed on the JUNO-NET
main board.
7
OPTIO
N
JUNO NET ACCESSORIES
Analogue addressable network control panel
If the system is distributed, the communication between the main panel and the external sub-panels or
repeaters is supported by either an RS422/485 fully redundant loop or alternatively fibre-optic cable.
In both cases the data loop is protected from interruptions or via short-circuits by creating a bi-directional
communication flow. If the main panel is unable to communicate with a sub-panel or repeater, it will try
reaching it through the opposite direction and signal a communication fault. If RS422/485 is to be used, the
cable needed will be a 4 core shielded and fire proof data cable, running a loop from the main panel through all
the repeaters and sub-panels in the system and returning to the main panel.
It is desirable to use fibre-optic cable for the data loop when longer distances between nodes demand it
(above 1200 m) or in premises with high levels of electrical disturbances. The cable used for this type of
connection should be dual core sheathed fire proof with 62.5/125 fibre terminated in ST connectors. This type
of data loop is also fully redundant and permits distances between nodes of up to 4.5 Km.
J-NET-INT- 485
EXTERNAL RS485 INTERFACE
Pr.Id.:30116
CHARACTERISTICS
WEIGHT:
DIMENSIONS:
OPTIO
N
34 grams
H: 25 W: 115 D: 10 (mm)
This board is a complement to the J-NET-INT-485, and provides
the screw connection terminals that do not fit in the former PCB is
reduced dimensions. It also provides spark-gap discharge
protectors for each in or outbound connection, improving the
degree of protection against atmospheric discharge interference.
J-NET-INT-FO
Pr.Id.:30117
FIBRE-OPTIC COMMUNICATION INTERFACE
CHARACTERISTICS
WEIGHT:
DIMENSIONS:
OPTIO
N
22 grams
H: 39 W: 77 D: 9 (mm)
This interface unit converts the TTL level networking signals to dual channel optical fibre
compatible levels, to allow long distance interconnection between a JUNO-NET main
panel and either one or more sub-panels and/or repeaters with or without integrated
sub-panels.
The optical inputs and outputs are inherently optically isolated from the panel or subpanel to which it is connected. This optical isolation avoids disturbance created by
ground loops and ensures complete protection from possible shock hazards and wiring
mistakes.
The TTL connections are via a 5 pin Molex connector which carries the supply and TTL
Quart COMS
Pr.Id.:30112
COMMUNICATION INTERFACE
CHARACTERISTICS
WEIGHT:
DIMENSIONS:
28 grams
H: 41 W: 65 D: 20 (mm)
When the need arises to interface the JUNO-NET with
the outside world, you will be required to use one of the
following units.
If your requirements are
Uploading/Downloading data from your PC to the main
panel, connecting your system to a graphics software
like the Odyssey or the installation of an external
printer, then you will need the J-NET-INT-COMS board
correctly configured for each of the above mentioned
purposes. Identification of the boards is by way of
labels since the corresponding configuration of each
board is done in factory.
8
OPTIO
N
F
or many fire alarm systems, all that is
required is a simple stand-alone fire alarm
panel, monitored by a receptionist or
security guard.
A printer can be connected to the computer to
record all alarm, fault and programming activity
on the system.
Pr.Id.:30111
Panel list screen with 5 panels connected
Initial alarm screen showing general area
Juno 1-3 loop panel display
Highest zoom showing detector in alarm
Juno NET panel display
Front page showing Telephone Nº utility
9
ADDRESSABLE DETECTORS
The X series is a precise, and high reliable EN-54 approved Analog Addressable smoke
alarms. It comes with a series of 3 different types: smoke only (X-O), heat only (X-T), and
smoke + heat combination (X-O/T) detection.
ADDRESSABLE X SERIES
ØDual
LEDs for 360°visibility
ØAdvanced detection and discrimination
algorithms
ØEasy installation and maintenance
ØSleek low-profile housing design
ØDurable sensor head, no need for
replacement
ØSMD circuit board design-satisfactory
quality and reliability guaranteed
ØFive-year limited warranty
ØSensor base option: standard and Shottky
Diode
Pr.Id.:32522
Model
2/4 Wire
Thermal / Optical
Voltage DC
Standby Current (Max)
Alarm Current (Max)
Surge Current (Max)
Start-Up Time (Max)
Permissible Current (Max)
Frequency
Base Model
Pr.Id.:32523
X-O
2
Optical
15-30V
370mA
370mA
370mA
30sec
80mA
3-5sec
X-B
X-T
2
Thermal
15-30V
370mA
370mA
370mA
30sec
80mA
3-5sec
X-B
10
Pr.Id.:32524
X-O/T
2
Thermal/Optical
15-30V
370mA
370mA
370mA
30sec
80mA
3-5sec
X-B
MANUAL CALL POINTS
X-MCPA-KAC
Pr.Id.:32114
ADDRESSABLE MANUAL CALL-POINT UNIT
ELECTRICAL CHARACTERISTICS
MECHANICAL CHARACTERISTICS
ADDRESSABLE LOOP CURRENT
LOOP CURRENT (NORMAL)
LOOP CURRENT (FIRE)
OPERATING TEMPERATURE:
HUMIDITY:
WEIGHT
DIMENSIONS
WIRE CAPACITY
FIXINGS
0,35 mA
3,1 mA
0 - 85°C
30 - 95% NON-CONDENSING
150 grams
H: 52 W: 87 D: 87 (mm)
up to 2,5mm2
surface mount: 4 holes
The X-MCPA-KAC manual call point uses a new
communication mechanism that gives a typical alarm response time
of approximately one second and yet does not use Apollo's patented
interrupt bit solution. This new communication system is fully
compatible with all our addressable modules, SAM's, S90, XP95 and
Discovery detectors. Like Apollo's interrupt based system, the more
call points on a loop, the longer the time from activation to alarm.
X-MCPA-FLAP
Pr.Id.:32526
ADDRESSABLE MANUAL CALL-POINT UNIT (LOW-PROFILE)
ELECTRICAL CHARACTERISTICS
MECHANICAL CHARACTERISTICS
ADDRESSABLE LOOP CURRENT
LOOP CURRENT (NORMAL)
LOOP CURRENT (FIRE)
OPERATING TEMPERATURE:
HUMIDITY:
WEIGHT
DIMENSIONS
WIRE CAPACITY
FIXINGS
0,35 mA
3,1 mA
0 - 85°C
30 - 95% NON-CONDENSING
80 grams
H: 28 W: 120 D: 80 (mm)
up to 2,5mm2
surface mount: 2 holes
Both the MCPA-KAC and the MCPA-FLAP are addressable manual callpoints, compatible with a version of the meter bus protocol used by several
panel manufacturers, used for signaling an emergency or fire situation to an
addressable fire detection control panel. The main features of these units are
their low quiescent power consumption and low cost. An 8 way DIL switch is
used for setting the address of the unit within the communication loop.
Addresses 0 to 125 can be programmed in binary code, where a switch in the
“OFF” position represents a “0”. This unit returns an analog value of 16 when
the glass is intact and a value of 64 when the glass panel has been pressed.
The unit is provided with a bi-color LED which signals with a green light flash
when the unit is being interrogated by the control panel. When in ALARM, the
LED is illuminated in red by command of the control panel.
S-MCPA-2470
Pr.Id.:32116
CONVENTIONAL MANUAL CALL-POINT UNIT (LOW-PROFILE)
ELECTRICAL CHARACTERISTICS
QUIESCENT DC CURRENT
FIRE CURRENT
OPERATING TEMPERATURE
HUMIDITY
MECHANICAL CHARACTERISTICS
40 µA
20 mA
0 - 85°C
30 - 95% NON-CONDENSING
WEIGHT
DIMENSIONS
WIRE CAPACITY
FIXINGS
80 grams
H: 52 W: 87 D: 87 (mm)
up to 2,5mm2
surface mount: 2 holes
The S-MCPC-2470 is a conventional manual call-point compatible with all conventional fire alarm control panels.
The main feature of this unit is the use of a bi-color LED to signal the operational status of the call-point. The
included LED blinks regularly with the green color while connected to a detection zone and lights with a permanent
red light when activated, (alarm condition). This, allied with its very competitive price and aesthetic appearance ,
make the S-MCPC-2470 a very attractive product.
11
ADDRESSABLE SOUNDERS
X-VIPER - A - SE
X-VIPER - A
X-VIPER BEACON
SOUNDERS FEATURING LOW POWER CONSUMPTION & HIGH SOUND OUTPUT
X-VIPER - A
VIPER ADDRESSABLE SOUNDER
Pr.Id.:32532
CHARACTERISTICS
STANDARD
17-40 V DC
SUPPLY VOLTAGE:
1 mA
CURRENT CONSUMPTION QUIESCENT:
6 mA
CURRENT CONSUMPTION ALARM:
11 mA
HIGH FREQUENCY SOUND:
94 - 125 (32/Loop)
ADDRESS RANGE:
SHADOW
17-40 V DC
1 mA
6 mA
11 mA
SHADOW (64/Loop)
153 grams
WEIGHT:
DIAMETER: 100 - HEIGHT: 85 (mm)
DIMENSIONS:
85dB @ 1 METRE (92dB High Pitch)
SOUND OUTPUT:
4 TONES SELECTED BY DIL SWITCH
TONES:
PROTECTION RATING: IP65
This addressable sounder is a surface mountable unit available in red and white colors with very low power
consumption as its main characteristic. It has a sound output of up to 92dBA with less than 5mA power
consumption @ 24V. It is possible to place up to 96 sounders or 64 sounder/beacons in a single loop, 32 of which
can be given a response address, the remaining being shadow sounders.
PROGRAMMING DATA FOR ADDRESSABLE BASE SOUNDER
SWITCH 7 & 8: OFF: SWEEP SOUND (800 - 1000 Hz)
ON
OFF
SWITCH 7 ON & 8 OFF: ALTERNATE SOUND (2800 - 3500 Hz)
ON
OFF
SWITCH 7 OFF & 8 ON: ALTERNATE SOUND (800 - 1000 Hz)
ON
OFF
SWITCH 7 & 8: ON: CONTINUOUS (800 Hz)
X-VIPER SE
Also exists in
SHADOW
version
(see BASE SOUNDER)
CONNECTION DIAGRAM
Pr.Id.:32529
CHARACTERISTICS
7
SWITCH 6: OFF: IAS LOOP SOUNDER ON: APOLLO SOUNDER CIRCUIT CONTROLLER
ON
OFF
++ _ _
SWITCHES 1-5: REGULAR ADDRESSES FROM 094 TO 125 IN BINARY
8
8
6
7
5
6
4
5
3
4
2
3
1
2
ON
OFF
++ _ _
1
ON
OFF
STANDARD
VIPER ADDRESSABLE SOUNDER - SPECIAL EDITION
SHADOW
SUPPLY VOLTAGE:
17-40 V DC
17-40 V DC
CURRENT CONSUMPTION QUIESCENT:
0.8 mA
0.8 mA
CURRENT CONSUMPTION ALARM:
3.5 mA
3.5 mA
+ SHADOW (64/Loop)
ADDRESS RANGE:
94 - 125 (32/Loop)
TONES:
4 TONES SELECTED BY DIL SWITCH
PROTECTION RATING:
IP65
125 grams
WEIGHT:
DIMENSIONS:DIAMETER: 100 - HEIGHT: 85 (mm)
SOUND OUTPUT- CONTINUOUS85 dB @ 1 METRE
SOUND OUTPUT- SWEEP:
85 dB @ 1 METRE
SOUND OUTPUT- ALTERNATING:85 dB @ 1 METRE
SOUND OUTPUT- HIGH PITCH: 92 dB @ 1 METRE
This addressable sounder is a surface mountable unit available in red and white colors with very low power
consumption as its main characteristic. It has a sound output of up to 92dBA with less than 5mA power
consumption @ 24V. It is possible to place up to 96 sounders or 64 sounder/beacons in a single loop, 32 of which
can be given a response address, the remaining being shadow sounders.
X-VIPER - BEACON
Pr.Id.:32531
VIPER ADDRESSABLE SOUNDER & BEACON
CHARACTERISTICS
17-40 V DC
SUPPLY VOLTAGE:
1 mA
CURRENT CONSUMPTION QUIESCENT:
4.5 mA
CURRENT CONSUMPTION ALARM:
94 - 125 (32/Loop)
ADDRESS RANGE:
4 TONES SELECTED BY JUMPERS
TONES:
IP44
PROTECTION RATING:
WEIGHT:
DIMENSIONS:
CONTINUOUS TONE:
RAMP TONE:
BI-TONAL
BI-TONAL
175 grams
DIAMETER: 100 - HEIGHT: 70 (mm)
1000Hz
800 - 1200Hz
1000 - 1300Hz
2000 - 2600Hz
This addressable sounder/beacon, is a surface mountable unit available in red color with very low power
consumption as its main characteristic. It has a sound output of up to 92dBA with less than 5mA power
consumption @ 24V. This includes a high power LED based beacon which uses 8 super-high efficiency RED
LED's. It is possible to place up to 96 sounders or 64 sounder/beacons in a single loop, 32 of which can be
given a response address, the remaining being shadow sounders. The beacon operation can be chosen
between two modes:
Mode A: The beacon operates simultaneously with the sounder and stops with the silencing.
Mode B: The beacon operates simultaneously with the sounder but does not stop flashing until the loop is
12
ADDRESSABLE SOUNDERS
X-VULCAN - A
PROGRAMMING DATA FOR ADDRESSABLE BASE SOUNDER
X-VULCAN
CHARACTERISTICS
2
3
4
5
6
7
8
SWITCHES 1-5: REGULAR ADDRESSES FROM 094 TO 125 IN BINARY
ON
OFF
SWITCH 6: OFF: IAS LOOP SOUNDER
ON: APOLLO SOUNDER CIRCUIT CONTROLLER
ON
OFF
SWITCH 7 & 8: OFF: SWEEP SOUND (800 - 1000 Hz)
ON
OFF
SWITCH 7 ON & 8 OFF: ALTERNATE SOUND (2800 - 3500 Hz)
ON
OFF
SWITCH 7 OFF & 8 ON: ALTERNATE SOUND (800 - 1000 Hz)
ON
OFF
SWITCH 7 & 8: ON: CONTINUOUS (800 Hz)
Pr.Id.:32533
STANDARD
1
2
3
4
5
6
7
8
++ _ _
++ _ _
1
ON
OFF
VULCAN ADDRESSABLE BASE SOUNDER
Accepts APOLLO XP95 Detector Base.
SHADOW
17-40 V DC
17-40 V DC
SUPPLY VOLTAGE:
0.8 mA
CURRENT CONSUMPTION QUIESCENT: 0.8 mA
3.5 mA
3.5 mA
CURRENT CONSUMPTION ALARM:
+ SHADOW (64/Loop)
94 - 125 (32/Loop)
ADDRESS RANGE:
4 TONES SELECTED BY JUMPERS
TONES:
IP44
PROTECTION RATING:
WEIGHT:
75 grams
DIMENSIONS:
DIAM.: 112 - HEIGHT: 37 (mm)
SOUND OUTPUT- CONTINUOUS 85 dB @ 1 METRE
SOUND OUTPUT- SWEEP:
85 dB @ 1 METRE
SOUND OUTPUT- ALTERNATING: 85 dB @ 1 METRE
SOUND OUTPUT- HIGH PITCH: 92 dB @ 1 METRE
This sounder is an ultra low power base sounder, intended to be used both as a stand-alone low profile
sounder, or as a combined detector plus sounder assembly. When configured as a SHADOW sounder, by
cutting the appropriate link, these sounders become invisible to the fire alarm control panel. This
characteristic means that although the panel can control the activation of the sounders - in up to 32 groups per
loop - each of these groups can have more than one and up to 64 sounders because the devices are not
reporting back to the panel. This also means that device addresses 94 to 125, hereto reserved for
addressable sounders, can be concurrently used by other device types, i.e. detectors and call points,
meaning that at this stage the total numbers of sounders per loop is raised to 64 together with up to 125 other
devices, detectors etc... This implies that the sounders are NOT monitored individually, but solely as part of
the detection loop.
13
SAM
SOFT ADDRESSABLE MODULE
Pr.Id.:32530
FEATURES
Fully encased for protection in high impact plastic
Small dimensions: 41.5 x 24.5 x 10.5 (mm)
Connections compatible with fork terminals or wire up to 1.5 mm2
Two versions available: SAM-S for Smoke detectors
SAM-H for Heat detectors
Up to 125 SAM's can be connected to a loop
SAM addresses are set by the test\commissioning sequence
SAM's can be fitted to the same loop as any of our addressable modules
SAM's can be fitted to the same loop as S90, XP95 and Discovery detectors
SAM addresses can be erased and re-programmed
Following strategy of providing competitive products for our esteemed customers, we are pleased to
announce the launch of SAM. This tiny, very low cost, module provides any conventional detector with an
address without the inconvenience of using a manual addressing unit or DIP switch. The SAM is simply
attached to the conventional detector and the detector address is automatically assigned to each SAM by the
JUNO-NET or JUNiOr control panel during commissioning and testing. A SAM based system tolerates loop
branches and can monitor loop interruptions and head removal. SAM is ideal for low budget retrofits where
fire point identification is needed but the cost of fitting a fully analogue system is too high. SAM is also an
option in low budget installations that would normally be implemented with 4 to 8 zone conventional systems.
It gives you the cable savings possible (see below) with an addressable system, together with the loop
sounder capability but without the extra costs of analogue addressable heads. Compatible with any make of
conventional detector, the SAM is fully encapsulated in a plastic case, unobtrusive and easy to connect to the
detector base.
SAME INSTALATION USING
JUNO-NET PANEL & SAM SYSTEM
CABLE REQUIRED: 78 METERS
CONVENTIONAL PANEL INSTALATION
CABLE REQUIRED: 200 METERS
3
2
1
3
2
1
4
4
5
5
6
7
6
4
7
8
8
A SAM system can prove economical as an alternative to conventional systems as small as 4 detection
zones. Up to 125 detection devices can be fitted to a single loop of fireproof cable. This, together with the
use of addressable loop powered sounders, keeps wiring costs to a minimum and gives the customer all the
flexibility and programmability of an addressable system at an extremely competitive price.
14
X-I/O
X-IN
X-IN
ADDRESSABLE SINGLE INPUT UNIT
Pr.Id.:32600
ELECTRICAL CHARACTERISTICS
ADDRESSABLE LOOP CURRENT
LOOP CURRENT (NORMAL)
LOOP CURRENT (O.C. FAULT)
LOOP CURRENT (S.C. FAULT)
LOOP CURRENT (FIRE)
MECHANICAL CHARACTERISTICS
WEIGHT
DIMENSIONS
WIRE CAPACITY
FIXINGS
mA
0,7
0,7
0,7
30 grams
H: 20 W: 45 D: 53 (mm)
up to 2,5mm2
surface mount: 4 holes
3,1
The INPUT UNIT is an addressable module, compatible with a version of the meter bus protocol used by several
panel manufacturers, which allows the connection of a normally open contact to an addressable fire detection
system.
This is normally used to signal an alarm or fault situation in machinery or other alarm situations like flooding, etc...,
by means of Fire detection system.
The module is supplied from the detection loop and monitors the connection to the monitored switch. This is done
by placing a 22 K ohm E.O.L. at the connections end and connecting a 4K7 resistor in series with the alarm switch.
The input status is visualized locally by a red LED, where the red light signals an alarm condition.
The INPUT unit is available as an electronic module with four fixing holes, or as a boxed unit for individual module
installations. The module detects and reacts to four bands of resistance between its input terminals, which are as
follows:
OPEN TO 50K - FAULT REPORTED
X-I/O
50K TO 8K2 - NORMAL REPORTED
Pr.Id.:32510
2K2 TO 0R0 - FAULT REPORTED
ADDRESSABLE SINGLE INPUT/OUTPUT UNIT
ELECTRICAL CHARACTERISTICS
ADDRESSABLE LOOP SUPPLY
LOOP CURRENT (NORMAL)
LOOP CURRENT (O.C. FAULT)
LOOP CURRENT (S.C. FAULT)
LOOP CURRENT (FIRE)
LOOP CURRENT (RELAY ACTIVE)
RELAY CONTACT RATING
8K2 TO 2K2 - FIRE REPORTED
MECHANICAL CHARACTERISTICS
WEIGHT
DIMENSIONS
WIRE CAPACITY
FIXINGS
mA
0,7
0,7
0,7
3,1
18,5
50V 1A Resistive
30 grams
H: 15 W: 52 D: 57 (mm)
up to 2,5mm2
surface mount: 4 holes
The I/O-ISO is an addressable module, compatible with a version of the meter bus protocol used by several panel
manufacturers, which allows the connection of a normally open contact to an addressable fire detection system,
providing at the same time an output relay contact to control ancillary equipment.
This is normally used to signal alarm or fault situations in machinery or other alarm situations like flooding etc...,
and controlling ancillary equipment, by means of the Fire detection system.
The module is supplied from the detection loop and monitors the monitored switch. This is done by placing a 22K
ohms E.O.L. resistors at the connections ends and wiring a 4K7 resistor in series with the alarm switch.
The input status is visualized locally by a red LED, where the red light signals an alarm condition.
The relay operation is signaled by a yellow LED which lights when the relay is actuated.
The power for actuating the relay can be external or drawn from the detection loop. The choice is made by shorting
two pads on the solder side of the PCB for loop power, or leaving those open if an external supply is available. By
default, the unit is prepared for loop power. The external supply is optically isolated from the detection loop. The
I/O-ISO is available as an electronic module with four fixing holes, or as a boxed unit for individual module
installations. The module detects and reacts to four bands of resistance between its input terminals, which are as
follows:
OPEN TO 50K - FAULT REPORTED
50K TO 8K2 - NORMAL REPORTED
15
8K2 TO 2K2 - FIRE REPORTED
2K2 TO 0R0 - FAULT REPORTED
X-I/O3
X-I/03
X-I/O8
ADDRESSABLE TRIPLE INPUT / OUTPUT UNIT
Pr.Id.:32527
ELECTRICAL CHARACTERISTICS
ADDRESSABLE LOOP SUPPLY
LOOP CURRENT (NORMAL)
LOOP CURRENT (O.C. FAULT)
LOOP CURRENT (S.C. FAULT)
LOOP CURRENT (FIRE)
RELAY CONTACT RATING
MECHANICAL CHARACTERISTICS
WEIGHT
DIMENSIONS
WIRE CAPACITY
FIXINGS
mA
0,7
3,1
3,1
80 grams
H: 20 W: 72 D: 88 (mm)
up to 2,5mm2
surface mount: 4 holes
3,1
50V 1A Resistive
The 3 I/O-ISO is an addressable module, compatible with a version of the Meter bus protocol used by several panel
manufacturers, which allows the connection of three normally open contacts to an addressable fire detection
system, providing at the same time three output relay contacts to control ancillary equipment. This is normally
used to signal alarm or fault situations in machinery or other alarm situations like flooding etc..., and controlling
ancillary equipment, by means of the Fire detection system. The module is supplied from the detection loop and
monitors the connection to the monitored switches. This is done by placing a 22K ohms E.O.L. resistors at the
connections ends and wiring a 4K7 resistor in series with the alarm switches. The input status is visualized locally
by three red LED's which signal a fire condition at the inputs, and a yellow common fault LED. The relay operation
is signaled by three red LEDs which light when the respective relays are actuated. The power for actuating the
relays is derived from an external P.S.U. The external supply is optically isolated from the detection loop. The 3
I/O-ISO is available as an electronic module with four fixing holes. The module detects and reacts to four bands of
resistance between its input terminals, which are as follows:
OPEN TO 50K - FAULT REPORTED
X-I/O8
50K TO 8K2 - NORMAL REPORTED
Pr.Id.:32601
8K2 TO 2K2 - FIRE REPORTED
2K2 TO 0R0 - FAULT REPORTED
ADDRESSABLE 8 INPUT / 2 OUTPUT UNIT
ELECTRICAL CHARACTERISTICS
MECHANICAL CHARACTERISTICS
ADDRESSABLE LOOP CURRENT
0.7 mA
LOOP CURRENT (NORMAL):
RELAY CONTACT RATING:
50V 1A RESISTIVE
WEIGHT
DIMENSIONS
WIRE CAPACITY
FIXINGS
60 grams
H: 20 W: 88 D: 74 (mm)
up to 2,5mm2
surface mount: 4 holes
The 8 I/O module is an addressable module, compatible with a version of the meter bus protocol used by several
panel manufacturers, which allows the connection of eight normally open contacts to an addressable fire detection
system, providing at the same time two output relay contacts to control a conventional fire alarm panel.
This module will normally be used to interface existing conventional fire alarm systems to an analogue
addressable fire control panel. The module is supplied from the detection loop but requires a nominal 24V DC
supply for relay energizing. This auxiliary supply can be derived from the conventional fire alarm panel. The alarm
silencing and reset functions of the conventional fire alarm panel can be executed by silencing and resetting the
analogue addressable fire control panel. The 8 inputs are digital normally open inputs that can be connected to the
zone repeater outputs of the conventional fire alarm panel. The silence and reset relay operation is signaled by
two green LEDs. The external supply is optically isolated from the detection loop.
16
X-LSCM
X-
X-LSCISO
Pr.Id.:32602
LOOP SOUNDER CONTROL MODULE WITH 1 AMP MONITORED OUTPUT
TECHNICAL CHARACTERISTICS
WORKING VOLTAGE:
QUIESCENT CURRENT CONSUMPTION:
ALARM CURRENT CONSUMPTION:
OPERATING TEMPERATURE:
HUMIDITY:
EXTERNAL SUPPLY
17-40 VOLTS DC
750uA MAX.
1.5mA MAX.
0 - 85°C
30 - 95% NON-CONDENSING
WORKING VOLTAGE:
QUIESCENT CURRENT CONSUMPTION:
ALARM CURRENT CONSUMPTION:
ISOLATION:
DIMENSIONS:
WEIGHT:
12 - 30 Volts DC
1.9mA max..
1A max.
500 Volts DC/max.
H: 19 W: 48 D: 58 (mm)
30 grams
The LSC-ISO is an externally powered sounder control module, designed mechanically to be mounted inside a
standard module box The main feature of this module is its capability to drive and monitor a bell output with a
maximum output of 1A. The wiring to the sounders is monitored for short and open circuit in quiescent mode
requiring a single 10K ohm resistor to be placed at the end of the monitored line. A six way DIL switch of which only
the first five sections are used allows programming of addresses 94 to 125. The output of the module is by a two
way terminal block where the line of conventional sounders is connected. The output can either be pulsed or
continuous. The protocol used by the LSC-ISO is only compatible with GFE's range of panels. A maximum
number of 32 modules can be connected to each addressable loop. The current derived to the sounder output is
limited to 1A which protects the output from overloading if the output is accidentally shorted. When the line
monitored is correctly terminated by a 10K ohm resistor an analogue value of 16 is returned upon interrogation of
the device. If the sounder line is either interrupted or short circuited at any point, a fault value of 4 is returned.
When in alarm, the analogue value reported by the device is always 17. This signals to the control panel that the
sounder controller has responded to its activation command.
X-LSCM
Pr.Id.:32603
LOOP SOUNDER CONTROL MODULE
TECHNICAL CHARACTERISTICS
WORKING VOLTAGE:
QUIESCENT CURRENT CONSUMPTION:
ALARM CURRENT CONSUMPTION:
OPERATING TEMPERATURE:
17-40 VOLTS DC
330uA MAX.
40mA MAX. (load dependent)
0 - 85°C
HUMIDITY:
DIMENSIONS:
WEIGHT:
30 - 95% NON-CONDENSING
H: 16 W: 37 D: 31 (mm)
15 grams
The LSCM1 is a loop powered sounder control module, designed mechanically to be mounted inside any
conventional sounder or beacon with up to 40mA consumption. The main features of this module are its low
power consumption in quiescent mode and its electronic and mechanical simplicity which make it a reliable
and economical piece of equipment. A six way DIL switch allows assigning of the address pertaining to each
sounder, in the range from 94 to 125. The first five switches define this address, where an "all off" setting
corresponds to address 94. Switch #6 defines the operation mode of the module; If this switch is OFF, the
module responds as an GFE sounder controller, if it is in the ON position, its operation will be equivalent to an
Apollo Sounder Circuit Controller. The output of the module is by two leads that are simply connected to the
terminals of the sounder or beacon which are relevant. The output can either be pulsed or continuous. The
protocol used by the LSCM1 is only compatible with GFE's range of panels. When exposed to a XP95
interrogation format the module just continues its power management function without disturbing the
communication of other XP95 devices in the loop. The current derived to the sounder output is limited to
40mA which protects the loop from overloading if the output is accidentally shorted. When a sounder is
connected to the module's output an analogue value of 16 is returned upon interrogation of the device. If no
connection is made to the output, a fault value of 4 is returned. When in alarm, the analogue value reported by
the device is always 17. This signals to the control panel that the sounder controller has responded to its
activation command.
17
X-ZMU4
X-ZMU
X-ZMU
ZONE MONITORING UNIT
Pr.Id.:32511
ELECTRICAL CHARACTERISTICS
MECHANICAL CHARACTERISTICS
mA
ADDRESSABLE LOOP SIDE
LOOP CURRENT (NORMAL)
LOOP CURRENT (O.C. FAULT)
LOOP CURRENT (S.C.FAULT)
LOOP CURRENT (FIRE)
2,9
1,5
1,5
3,1
EXTERNAL SUPPLY SIDE
SUPPLY CURRENT (NORMAL)
SUPPLY CURRENT (O.C. FAULT)
SUPPLY CURRENT (S.C.FAULT)
SUPPLY CURRENT (FIRE)
mA
7
1,5
60
30
WEIGHT
30 grams
DIMENSIONS
H: 20 W: 60 D: 60 (mm)
WIRE CAPACITY UP TO 2,5 mm2
The ZMU is an addressable module, compatible with a version of the meter bus protocol used by several panel
manufacturers, and which allows the connection of a number of conventional smoke or heat detectors and manual
call-points, to an addressable fire detection system. This means that from a detection and alarm processing point
of view, that group of detection devices is given an address and considered as an unique alarm source. Using this
module is a natural option in the protection of large areas, like underground parking lots, where the expense of
using addressable detectors is not justifiable, even though the configuration of the rest of the building requires
those. This module can draw its power from the communication loop which dispenses with the need for an
additional power supply connection, or be supplied from an external power supply unit. This is defined by
removing the two jumpers installed as a default. The unit controls a zone of conventional detectors with a 4K7 ohm
passive E.O.L. Because the current drawn from the loop can be significant, especially in Fire and S.C. Fault
conditions, the number of modules that can be supplied is limited. The current status is visualized locally by a dual
color LED, where the green light means a normal current condition, a red light signals a fire condition and no light
indicates a fault. The unit monitors the external power supply, reporting a fault if the auxiliary power is not present.
The ZMU is available as an electronic module with four fixing holes, or as a boxed unit for individual module
installations. The module detects and reacts to four bands of zone current which are interpreted and signaled to
the control panel and which are as follows:
0 TO NORMAL - FAULT REPORTED
X-ZMU4
NORMAL TO ALARM - NORMAL REPORTED
Pr.Id.:32528
ALARM TO SHORT CCT - FIRE REPORTED
ADDRESSABLE 4 ZONE MONITOR UNIT EXTERNALLY POWERED
ELECTRICAL CHARACTERISTICS
ADDRESSABLE LOOP SIDE
LOOP CURRENT (NORMAL)
LOOP CURRENT (O.C. FAULT)
LOOP CURRENT (S.C.FAULT)
LOOP CURRENT (FIRE)
SHORT CCT - FAULT REPORTED
MECHANICAL CHARACTERISTICS
mA
1,5
1,5
1,5
1,5
mA
EXTERNAL SUPPLY SIDE
SUPPLY CURRENT (NORMAL)
7 / CCT
SUPPLY CURRENT (O.C. FAULT)1,5 / CCT
SUPPLY CURRENT (S.C.FAULT) 60 / CCT
SUPPLY CURRENT (FIRE)
30 / CCT
WEIGHT
130 grams
DIMENSIONS
H: 20 W: 75 D: 148 (mm)
WIRE CAPACITY UP TO 2,5 mm2
The QUAD-ZMU is an addressable module, compatible with a version of the meter bus protocol used by several
panel manufacturers, and which allows the connection of four zones with a number of conventional smoke or heat
detectors and manual call-points, to an addressable fire detection system, using four consecutive addresses. This
means that from a detection and alarm processing point of view, each group of detection devices is given an
address and considered as an unique alarm source. Using this module is a natural option in the protection of large
areas, like underground parking lots, where the expense of using addressable detectors is not justifiable, even
though the configuration of the rest of the building requires those. This module requires the connection of 24V DC
supply which is permanently monitored and allows the connection of four standard zones of detectors with 4K7
ohm passive E.O.L. The detection zones and their supply voltage are optically isolated from the addressable
detection loop, which allows the use of a local independent power supply. If that supply fails, a FAULT condition is
reported to the control panel. The current status of each zone is visualized locally by two LED’s, where the yellow
light means a fault condition and a red light signals a fire condition and no light indicates a normal situation. A green
LED indicates that there is power on the zone connections. The individual zones of this module detect and react to
four bands of zone current which are interpreted and signaled to the control panel and are as follows:
0 TO NORMAL - FAULT REPORTED
NORMAL TO ALARM - NORMAL REPORTED
ALARM TO SHORT CCT - FIRE REPORTED
18
SHORT CCT - FAULT REPORTED
ACCESSORIES
X-IND
Pr.Id.:32521
FLASHING REMOTE INDICATOR
CHARACTERISTICS
WORKING VOLTAGE RANGE:
CURRENT CONSUMPTION:
3 - 15 V DC
300 µA - 15 mA
DIMENSIONS: FACE PLATE
DIMENSIONS: INDICATOR:
76 x 76 x 2 (mm)
68 x 33 x 25 (mm)
This remote indicator can be used with any fire alarm detector, be it of
the conventional or addressable/analogue types, to indicate
remotely the activation of the relevant detection device. It’s main
characteristics are the high visibility due to the alternate blinking of
two high efficiency LED’s (“A” Version), and the wide operating
voltage range 3 to 15 DC Volts, with a minimum of 300 µA current
consumption. The two connections of this device are non-polarized,
avoiding wasted time at the installation phase. The unit comes
complete with a face plate compatible with standard flush mounting
boxes.
JUNCTION BOX
Pr.Id.:32604
ABS MULTI PURPOSE JUNCTION BOX
Our ABS molded multi purpose
junction box is provided in RED or
WHITE color with matching snap-on
cover and has four mounting holes
compatible with our single channel
addressable modules. It is intended
for surface use but can also be
embedded.
Weight with cover: 74 grams.
485 INT
RS232/RS485 CONVERTER
Pr.Id.:32605
CHARACTERISTICS
SUPPLY VOLTAGE:
OPERATING CURRENT:
MAX BAUD RATE:
20-30V.
25mA max.
9600 baud
WEIGHT:
DIMENSIONS:
This optically isolated converter can be used to connect RS232
signaling equipment over distances up to 1200 m. It is mainly
used in conjunction with the JUNO panels and repeaters.
19
44 grams
H: 51 W: 101 D: 16 (mm)
CONVENTIONAL DETECTORS
S-T Series
RProduct Features:
R4 wire models
RDual LEDs for 360°visibility
RAdvanced detection and discrimination algorithms
REasy installation and maintenance
RSleek low-profile housing design
RDurable sensor head, no need for replacement
RSMD circuit board design-satisfactory quality and
reliability guaranteed
RIntegrated heat detector for S-T models
RFive-year limited warranty
RN/C (normal/close)-N/O (normal/open)selectable relay
output
RAR (Auto Reset) function for security systems
R(optional for 4 wire models)
RSensor base option: standard and Shottky Diode
S-O Series
R4 wire models
RDual LEDs for 360°visibility
RAdvanced detection and discrimination algorithms
REasy installation and maintenance
RSleek low-profile housing design
RDurable sensor head, no need for replacement
RSMD circuit board design-satisfactory quality and
reliability guaranteed
RRemote LED
RFive-year limited warranty
RN/C (normal/close)-N/O (normal/open)selectable relay
output
RAR (Auto Reset) function for security systems
R(optional for 4 wire models)
RSensor base option: standard and Shottky Diode
Pr.Id.:32541
Model
2/4 Wire
Thermal / Optical
Voltage DC
Standby Current (Max)
Alarm Current (Max)
Surge Current (Max)
Start-Up Time (Max)
Permissible Current (Max)
Frequency
Base Model
S-O
4
Optical
10-15V
55mA
50mA
150mA
60sec
80mA
4-6sec
S-B
20
Pr.Id.:32540
S-T
4
Thermal / 57°C
10,2-13,8V
370mA
35mA
120sec
80mA
3-5sec
S-B
ACCESSORIES, GAS DETECTORS
Air Sampling Unit Pr.Id.:32502
B-IC Air sampling unit is designed for use with Firex series smoke
detectors.The unit enables smoke detectors to be sited within
ventilation extract ducts in order to assist in the prevention of the
spread of smoke by the ventilation system.
BL-151 Relay Adapter Pr.Id.:32501
Relay adapter that allows connection of conventional fire detectors
to the ergular alarm system.
General features are:
Free switching for alarm signalling.
Pree switching for fault signalling
Detector line reset button
Connect from 7-10 detectors to one BL-151
Electro - magnetic door holder
Electromagnetic door holder type 1340 and 1360.
Features:
1340 Type: 100kg Pr.Id.:32506
1360 Type: 100kg with housing and release key
G55 Series Gas Detectors
Pr.Id.:32507
Pr.Id.:32604
The G55 series gas detectors include detectors for following gases:
methane, butane, gasoline fumes, CO (carbon monoxinde),
hydrogen, propane.
Please check with your distributor which type of detector you need.
B55 Series Sample Gases
In order to set the G55 detectors optimally you will need to
purchase and use the B55 Sample Gas. Each detector type
requires affiliate gas.
Conventional fire sirens and flashing lights
We are offering you a wide variety of audible, visual and visualaudible annunciators.
Some features:
Type SP-30; audible addressible annunciator
Type Solo/24; visual - audible outdoor annunciator with 4 ohms at
117dB@1m
1484; flashing light 12/24Vdc