* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download about voltage total harmonic distortion for single
Mercury-arc valve wikipedia , lookup
Electric power system wikipedia , lookup
Spark-gap transmitter wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Stepper motor wikipedia , lookup
Power engineering wikipedia , lookup
Electrical ballast wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Current source wikipedia , lookup
Integrating ADC wikipedia , lookup
History of electric power transmission wikipedia , lookup
Electrical substation wikipedia , lookup
Power MOSFET wikipedia , lookup
Schmitt trigger wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Opto-isolator wikipedia , lookup
Power inverter wikipedia , lookup
Surge protector wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Voltage regulator wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Buck converter wikipedia , lookup
Stray voltage wikipedia , lookup
Alternating current wikipedia , lookup
Voltage optimisation wikipedia , lookup
ABOUT VOLTAGE TOTAL HARMONIC DISTORTION FOR SINGLE- AND THREE-PHASE MULTILEVEL INVERTERS ABSTRACT Many recent multilevel inverter papers end up with voltage total harmonic distortion (THD) values obtained from numerical voltage spectrum calculations (measurements). Motivated by IEEE Standard 519, a part of the multilevel research community uses a limited harmonic count to evaluate the multilevel voltage quality. First, this causes significant voltage THD underestimation, particularly for relatively high frequency PWM. Second, for a three-phase star-connected balanced load with an isolated neutral and phase symmetric modulation strategy, the calculated load line and phase voltage THD become different. However, simple considerations show that line and phase voltage THDs are essentially the same in this case. It may be difficult to judge about the multilevel voltage quality given a numerically calculated (measured) voltage THD value that may be subject to computation errors. Presented are simple smooth hyperbolic voltage THD upper and lower bound approximations for single- and three-phase inverters with nearest synchronous switching. They are valid for arbitrary modulation indices and uniformly distributed level counts and may practically serve as good reference values. Some papers on cascade H-bridge three-phase converter with fundamental switching like and may seem misleading as they talk about different line and phase voltage THDs. Indeed, for the inverter side, phase (phase to inverter neutral) and line voltage THDs are different. However, in this paper proposes a star connected balanced load with an isolated neutral, line and phase (phase to load neutral) voltage THDs have to be the same. The theoretical upper bound that is achieved for an infinitely high switching frequency is practically quite accurate for the ratios of switching and fundamental frequencies that are larger than 25–30 and is valid for both singleand three-phase inverters. The theoretical voltage quality lower bound is achieved for a minimum amount of synchronous switching that is once between any two adjacent voltage levels. Head office: 2nd floor, Solitaire plaza, beside Image Hospital, Ameerpet, Hyderabad www.kresttechnology.com, E-Mail: [email protected] , Ph: 9885112363 / 040 44433434 1 Block diagram for proposed system Star-connected balanced three-phase load with isolated neutral. (a) Schematic. (b) Voltagephasor diagram for a symmetrical load and supply. DESIGNG SOFTWARE AND TOOLS: MAT LAB /SIMULATION Software and sim power systems tools are used. Mainly control system tools, power electronics and electrical elements tools are used. Head office: 2nd floor, Solitaire plaza, beside Image Hospital, Ameerpet, Hyderabad www.kresttechnology.com, E-Mail: [email protected] , Ph: 9885112363 / 040 44433434 2