Download vRealize Operations Management Pack for Storage Devices 6.0.3

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Distributed firewall wikipedia , lookup

Wireless USB wikipedia , lookup

Cracking of wireless networks wikipedia , lookup

Network tap wikipedia , lookup

Parallel port wikipedia , lookup

Zero-configuration networking wikipedia , lookup

Storage virtualization wikipedia , lookup

Transcript
vRealize Operations Management Pack
for Storage Devices 6.0.3 Guide
This document supports the version of each product listed and
supports all subsequent versions until the document is
replaced by a new edition. To check for more recent editions
of this document, see http://www.vmware.com/support/pubs.
EN-001750-02
vRealize Operations Management Pack for Storage Devices 6.0.3 Guide
You can find the most up-to-date technical documentation on the VMware Web site at:
http://www.vmware.com/support/
The VMware Web site also provides the latest product updates.
If you have comments about this documentation, submit your feedback to:
[email protected]
Copyright © 2015 VMware, Inc. All rights reserved. Copyright and trademark information.
VMware, Inc.
3401 Hillview Ave.
Palo Alto, CA 94304
www.vmware.com
2
VMware, Inc.
Contents
About This Book 5
1 Introduction to the
vRealize Operations Management Pack for Storage Devices 7
2 Installing and Configuring the Management Pack 9
Install the Management Pack 9
Add Credentials and Fabric Servers for the Management Pack for Storage Devices 10
Verify That Your Management Pack for Storage Devices Is Connected and Collecting Data
Ports and Log Files 13
12
3 Management Pack for Storage Devices Dashboards 15
4 Management Pack for Storage Devices Alert Definitions 17
5 Management Pack for Storage Devices Metrics 25
Statistical Metrics of the Management Pack for Storage Devices 25
Object Properties 33
6 User Scenario: An Object in Your Storage Network Has a Performance
Problem
39
User Scenario: Use the Troubleshooting Dashboard to Locate the Real Problem Source 39
User Scenario: Examine Metrics to Find the Root Cause 40
Index
VMware, Inc.
41
3
vRealize Operations Management Pack for Storage Devices 6.0.3 Guide
4
VMware, Inc.
About This Book
The vRealize Operations Management Pack for Storage Devices Guide provides you with a complete view of your
entire storage topology from your host, through your storage network, and out to the storage array. With
this solution, you can use vRealize Operations Manager to monitor and troubleshoot capacity and
performance problems on different components of your storage area network.
Intended Audience
The information in this guide is intended for storage administrators, data center architects, and IT operators.
VMware Technical Publications Glossary
VMware Technical Publications provides a glossary of terms that might be unfamiliar to you. For definitions
of terms as they are used in VMware technical documentation, go to
http://www.vmware.com/support/pubs.
VMware, Inc.
5
vRealize Operations Management Pack for Storage Devices 6.0.3 Guide
6
VMware, Inc.
Introduction to the
vRealize Operations Management
Pack for Storage Devices
1
The Management Pack for Storage Devices provides you with a complete view of your entire storage
topology from your host, through your storage network, and out to the storage array. With this solution,
you can use vRealize Operations Manager to monitor and troubleshoot capacity and performance problems
on different components of your storage area network.
The Management Pack for Storage Devices has the following features:
Provides an end-to-end view of topology, statistics, and events at every affected level of the storage area
network.
n
n
Enables a vSphere administrator working with a virtual environment to isolate problems caused by
elements in the physical storage stack, such as the Host Bus Adapter (HBA), storage switches, and
array. The vSphere administrator uses this information to hand off the problem to the domain
administrator for further analysis.
n
Captures and analyzes information for throughput and latency on the HBA and mount objects.
Captures throughput on the switch ports.
n
Captures IOPS and queue depth at the HBA and switch ports for read and write components.
n
Discovers the storage switches and applies the credentials required to collect data from the objects in
the storage network. It uses the Common Information Model (CIM) to exchange information with
objects managed by the following management systems:
Cisco Data Center Network Manager (DCNM)
n
n
VMware, Inc.
Brocade Network Advisor (BNA)
7
vRealize Operations Management Pack for Storage Devices 6.0.3 Guide
8
VMware, Inc.
Installing and Configuring the
Management Pack
2
When you install a management pack, you install the PAK file that you downloaded as part of the solution,
and you configure the management pack instance.
This chapter includes the following topics:
n
“Install the Management Pack,” on page 9
n
“Add Credentials and Fabric Servers for the Management Pack for Storage Devices,” on page 10
n
“Verify That Your Management Pack for Storage Devices Is Connected and Collecting Data,” on
page 12
n
“Ports and Log Files,” on page 13
Install the Management Pack
If your environment includes multiple vCenter Server systems on the same storage network, you must add
fabric switch CIM servers for each adapter instance. The adapter instance provides you with a holistic view
of the storage network connected to the vCenter Server system. The adapter discovers the storage devices
only for the ESXi 5.1 update 2 and later.
NOTE Any adapter credentials you add are shared with other adapter administrators and
vRealize Operations Manager collector hosts. Other administrators might use these credentials to configure
a new adapter instance or to move an adapter instance to a new host.
Prerequisites
Verify that the following conditions are met:
n
Read-only credentials are not adequate to connect and collect data from the vCenter Server and fabric
CIM servers. You must provide credentials with sufficient privileges. If the user account has limited
access to objects in vCenter and the fabric CIM server, you can only collect data from objects for which
you have permission.
n
The CIM agent is enabled on all storage network switches from which you are collecting data, and that
you can provide credentials with sufficient privileges to connect and collect data. If the user account has
limited access to objects in the storage environment, you can only collect data from objects for which
you have permission. Credentials must include at least read permissions.
n
All storage network switches with the CIM agent enabled are added to DCNM or BNA solutions.
n
The fabric CIM service supports switch profile and fabric profile. The supported versions for the Fabric
Profile are 1.1 to 1.6.
VMware, Inc.
9
vRealize Operations Management Pack for Storage Devices 6.0.3 Guide
n
A vSphere API for Storage Awareness (VASA) provider is registered as a storage provider with the
vCenter Server host for your adapter instance. VASA providers gather information from arrays that
support the environment and provide the data to vCenter Server system. If the VASA provider is not
registered with vCenter Server host, the Management Pack for Storage Devices cannot discover objects
in the array. The minimum support version is VASA 1.0. See information regarding storage providers
in the ESXi and vCenter Server 5.5 Documentation.
n
Specify the search domain value on vRealize Operations Manager to reach vCenter, hosts, and switches
using their Domain Name System (DNS) names instead of IP addresses. The resolv.conf file is used by
vRealize Operations Manager to connect to remote machines over the network. You must configure the
file correctly so that vRealize Operations Manager can reach the destination machines, such as vCenter,
ESXi hosts, or Fibre Channel (FC) switches. As a workaround, you can specify the search domain in
the /etc/resolve.conf file on vRealize Operations Manager and then restart the collector.
n
Download and install the Management Pack for Storage Devices.
Procedure
1
Log in to the vRealize Operations Manager user interface with administrator privileges.
2
In the left pane of vRealize Operations Manager, click the Administration icon and click Solutions.
3
On the Solutions tab, click the plus sign.
4
On the Solutions tab, select Management Pack for Storage Devices and click Configure.
5
Browse to locate the temporary folder and select the PAK file.
For example, managementpack_name-buildnumber.pak.
6
Click Upload.
The upload might take several minutes.
7
Read and accept the EULA, and click Next.
Installation details appear in the window during the process.
8
Ensure that you install the PAK file on the master node.
9
When the installation is complete, click Finish.
What to do next
Add credentials and add the fabric servers
Add Credentials and Fabric Servers for the
Management Pack for Storage Devices
When configuring an adapter instance for the Management Pack for Storage Devices, you add credentials
for a vCenter Server.
Procedure
1
In the vCenter Server text box, enter the FQDN or IP address of the vCenter Server instance to which
you are connecting.
The vCenter Server FQDN or IP address must be reachable from all nodes in the
vRealize Operations Manager cluster.
10
VMware, Inc.
Chapter 2 Installing and Configuring the Management Pack
2
To add credentials on the Manage Solution page, click the plus sign.
a
In the Credential name text box, enter the name by which you are identifying the configured
credentials.
b
Type the User name and Password for the vCenter Server instance.
c
Click OK.
You configured credentials to connect to a vCenter Server instance.
3
Click Test Connection to validate the connection with your vCenter Server instance.
4
Accept the vCenter Server security certificate.
5
Enter the SNMP Community Strings for your SNMP v2 enabled IP Network Switches.
6
To add fabric servers, click Add Fabric Server.
a
Click the plus sign.
b
Enter a name and description for the fabric server.
c
Enter the fabric switch CIM server IP or URL of the host on which the CIM server is installed.
The Management Pack for Storage Devices supports CIM servers that manage Fibre Channel
switches only. It does not support CIM servers that manage arrays.
Option
Action
Brocade fabric
Enter the IP address
Cisco fabric
Enter the service URL in the following format:
https://<IP/Hostname>:<Port>/<Implementation Namespace>,
for example, https://1.2.3.4:5989/cimv2.
d
To add credentials, click the plus sign.
e
In the Credential name text box, enter the name by which you are identifying the configured
credentials.
f
Enter the user name and password for the Brocade or Cisco Fabric Switch CIM server.
For the Cisco Fabric Switch CIM server, the user name and password are for the Cisco Data Center
Network Manager (DCNM) and not the Cisco switch.
7
g
Accept all the security certificates from the Fabric Switch CIM Server.
h
Click OK.
Click Save Settings.
The adapter is added to the Adapter Instance list and is active.
What to do next
To verify that the adapter is configured and collecting data from the objects in the storage topology, wait a
few collection cycles, then view application-related data.
n
Inventory Explorer. Verify that all the objects related to the Storage Devices Instance are listed. Objects
should be in the collecting state and receiving data.
n
Dashboards. Verify that the Storage Components Heatmap, the Storage Components Usage, and the
Storage Troubleshooting are added to the default dashboards.
VMware, Inc.
11
vRealize Operations Management Pack for Storage Devices 6.0.3 Guide
Verify That Your Management Pack for Storage Devices Is Connected
and Collecting Data
You configured an adapter instance of the Management Pack for Storage Devices with credentials for a
vCenter Server. Now you want to verify that your adapter instance can retrieve information from objects in
the host, switch, and array domains of your environment.
To view the object types, from the left pane of the vRealize Operations Manager user interface, click
Administration > Inventory Explorer > Adapter Instances > Storage device Instances >
<User_Created_Instance>.
Table 2‑1. Object Types that the Management Pack for Storage Devices Discovers
12
Object Type
Description
Active Zone Set
A collection of all active zones in the storage network.
ESX pNic
The physical Network Interface Cards (NICs) on the ESXi host.
Fabric
In the Brocade storage network, fabric is a collection of interconnected switches. There is
typically a one-to-one relationship between the fabric and the SAN.
In the Cisco storage network, fabric is a virtual SAN which is collection of one or more logical
switches. There is typically a one-to-many relationship between the SAN and the fabric.
Fabric Switch CIM
Server
CIM server that manages the switches. It provides the username, password and URL
information that the Management Pack for Storage Devices uses to discover storage network
objects such as fabric, switches, and switch ports.
Host Adapter
The Fibre Channel (FC) or Fibre channel over Ethernet (FcoE) host adapters in the host
system.
IP Switch
The Simple Network Management Protocol (SNMP) v2 enabled (IP) network switches
IP Switchport
The switch ports on your SNMP v2 enabled IP network switches
Logical Switch
A logical switch abstraction for the Cisco storage network. It is a collection of one or more
switch ports that are accessible to one other.
Magnetic Disks
Magnetic disks on the ESXi hosts.
Mount
A storage LUN abstraction that is available on the host system.
NFS Client
Network File System (NFS) clients on the ESXi hosts.
NFS Servers
NFS servers registered with vCenter via VASA.
No Existing Object
Container
A container that includes all the objects that are no longer discovered in the storage devices
topology.
SAN (Storage Area
Network)
In the Brocade storage network, the SAN is a collection of fabrics. There is typically a one-toone relationship between the SAN and the fabrics.
In the Cisco storage network, the SAN is a collection of one or more Virtual Storage Area
Networks (VSAN).
Solid State Device
Solid State Devices (SSDs) on the ESXi hosts.
Storage Array
The storage array registered to the VASA provider in the vCenter for the adapter instance.
Storage Devices Instance
The Management Pack for Storage Devices instance.
Storage LUN
The storage LUN of a storage array.
Storage Processor
The storage controller on the storage array.
Switch
The switch on the storage network that connects the host to the storage array.
Switch Port
The port on a switch.
Target Port
The target port of a storage array.
VirtualSAN Cluster
Virtual SAN clusters in your data center.
VMware, Inc.
Chapter 2 Installing and Configuring the Management Pack
Table 2‑1. Object Types that the Management Pack for Storage Devices Discovers (Continued)
Object Type
Description
VirtualSAN Datastore
Virtual SAN datastores in your data center.
VirtualSAN Diskgroups
A collection of SSDs and magnetic disks used by Virtual SAN.
Zone
A collection of target ports or host adapters in the storage network.
Procedure
1
In the left pane of vRealize Operations Manager, click the Administration tab and click Inventory
Explorer.
2
In the list of tags, expand Adapter Instances and expand Storage Devices Instance.
3
Select the adapter instance name to display the list of objects discovered by your adapter instance.
4
Slide the display bar to the right to view the object status.
5
Object Status
Description
Collection State
If green, the object is connected.
Collection Status
If green, the adapter is retrieving data from the object.
Deselect the adapter instance name and expand the Object Types tag.
Each Object Type name appears with the number of objects of that type in your environment.
6
Verify that you have at least one object in each of the network areas that the
Management Pack for Storage Devices discovers.
What to do next
If objects are missing or not transmitting data, you might need to investigate further.
n
If an object is not connected or not transmitting data, search for the object and check for related alerts.
n
If the adapter does not discover at least one object on the host system, in the storage network, and in the
storage array, verify that your environment is configured properly. Common configuration problems
such as invalid credentials, Fabric Switch CIM servers not reachable, or VASA providers not registered
in the vCenter Server instance are raised as alerts for the Management Pack for Storage Devices
instance.
Ports and Log Files
Some services and ports must be available to communicate with the rest of the data center.
External Interfaces, Ports, and Services required by the
Management Pack for Storage Devices
For monitoring Fiber Channel (FC) and Fiber Channel over Ethernet (FCoE) using CIM protocol (SMI-S
standard):
n
Port 5989 must be open on each ESXi host.
n
Port 5988 must be open on each FC Switch using http or port 5989 must be open on each FC Switch
using https.
For monitoring NFS and iSCSI topologies over ethernet switches using CDPv2, LLDPv2, and SNMPv2:
n
Ports 161 and 162 must be open on ethernet switches for SNMP.
n
CDP and LLDP advertisements/TLVs must be permitted on the network.
VMware, Inc.
13
vRealize Operations Management Pack for Storage Devices 6.0.3 Guide
Log Files and Security Updates
Log files are available in the vRealize Operations Manager platform in the /usr/lib/vmwarevcops/user/log/adapters/UniversalStorageAdapter3/ folder. Administrator privileges are assigned to
service users.
You can download and apply the latest security update from Solutions Exchange.
14
VMware, Inc.
Management Pack for Storage
Devices Dashboards
3
When the Management Pack for Storage Devices is installed, it adds preconfigured dashboards and alert
definitions that you use to monitor and troubleshoot the components in your storage area network.
Table 3‑1. Management Pack for Storage Devices Dashboards
Dashboard for protocols such
as FC-FCoE, iSCSI, NFS, and
Virtual SAN
Purpose
Troubleshooting
View end-to-end storage topology, health, and alerts on storage components.
Component/Entity Usage
Provides an overview of the most frequently used objects on the storage network and
tracks the error count on these objects.
Heatmap
Provides an overview of object performance against its predefined limits.
VirtualSAN Device Insights
Provides insights into device level details including capacity, usage, and errors of
devices used by Virtual SAN.
VirtualSAN Cluster Insights
Provides insights into cluster level details for disk groups and Virtual SAN
datastores.
VMware, Inc.
15
vRealize Operations Management Pack for Storage Devices 6.0.3 Guide
16
VMware, Inc.
4
Management Pack for Storage
Devices Alert Definitions
When the Management Pack for Storage Devices is installed, it adds preconfigured dashboards and alert
definitions that you use to monitor and troubleshoot the components in your storage area network.
vRealize Operations Manager generates an alert if a problem occurs with the components in the storage area
network that the Management Pack for Storage Devices is monitoring.
Table 4‑1. Management Pack for Storage Devices Alert Definitions
Alert
Level
Affected Object
Type
Adapter Configuration failed
(AdapterNotConfigured)
Critical
Storage Devices
Adapter Instance
Triggered when the
Management Pack for Storage
Devices instance is incorrectly
configured because of invalid
credentials or inaccessible Fabric
CIM or vCenter Server instances.
Clears when the adapter is
reconfigured and can successfully
communicate with data sources,
such as Fabric CIM or
vCenter Server.
All Paths Down on some Mounts
(APD)
Critical
VMWARE: Host
System
Triggered by an All Paths Down
(APD) situation on one or more
mounts on the host system. This
generic alert applies when the root
cause for APD cannot be attributed
to a zone configuration change, host
adapter link failure, or switch port
failure.
Clears when the APD situation is
resolved on the host system.
All Paths Down on some Mounts because HBA
is Link down
(APDHostAdapterLinkDown)
Critical
VMWARE: Host
System
Triggered by an APD situation on
one or more mounts on the host
system because of a problem with
the host adapter.
Clears when the APD situation is
resolved on the host system.
All Paths Down On Some Mounts because the
physical NIC status is down
(APDPnicDown)
Critical
VMWARE: Host
System
Triggered by an APD situation on
one or more mounts on the host
system, because of the problem with
the physical Network Interface Card
(NIC) connection to the host
adapter.
Clears when the APD situation is
resolved on the host system.
Alert (ID name)
VMware, Inc.
Description
17
vRealize Operations Management Pack for Storage Devices 6.0.3 Guide
Table 4‑1. Management Pack for Storage Devices Alert Definitions (Continued)
Alert
Level
Affected Object
Type
All Paths Down On Some Mounts Because
Switch Ports connected to the HBAs is Down
(APDInitiatorSwitchPortDown)
Critical
VMWARE: Host
System
Triggered by an APD situation on
one or more mounts on the host
system, because of a problem with
the switch port connection to the
host adapter.
Clears when the APD situation is
resolved on the host system.
All Paths Down On Some Mounts Because
Switch Port connected to the Target is Down
(APDTargetSwitchPortDown)
Critical
VMWARE: Host
System
Triggered by an APD situation on
one or more mounts on the host
system, because of a problem with
the switch port connection to the
target port on the array side.
Clears when the APD situation is
resolved on the host system.
All Paths Down on some mounts because
HBAs are zoned out
(APDZoneConfiguration)
Critical
VMWARE: Host
System
Triggered by an APD situation on
one or more mounts on the host
system. This alert indicates a loss of
connectivity between the host
adapters on the host side and target
ports on the array side because of
zone configuration changes.
Clears when the APD situation is
resolved on the host system.
Congestion due to high network bandwidth
usage
(NetworkBandwidthCongestion)
Critical
EsxPnic
Triggered when the physical NIC
bandwidth is over-utilized. Another
symptom when the physical NIC
capacity is less than 10 GB is also
checked, if applicable.
Clears when the physical NIC
bandwidth usage comes back to
normal.
Datacenter has some HBAs that are not
operating at maximum supported speed
(HostAdapterSpeedNotOptimal)
Info
VMWARE:
Datacenter
Triggered if a connected HBA is not
operating at its maximum supported
speed.
Clears when the HBA returns to its
maximum operating speed.
Fabric CIM server certificate is not trusted
(FabricCIMServerUntrusted)
Critical
Fabric CIM
Server
Triggered if the
Management Pack for Storage
Devices cannot authenticate the
fabric CIM server certificate.
Clears when the adapter can
authenticate the fabric CIM server
certificate.
Fabric CIM Server Configuration failed
(FabricCredentialsWrong)
Critical
Fabric Switch
CIM Server
Triggered if the
Management Pack for Storage
Devices cannot communicate with
the fabric switch CIM server using
the login credentials or URL
information provided.
Clears when the adapter can
communicate with the fabric switch
CIM server.
HBA Link Failure
(HostAdapterLinkDown)
Critical
Host Adapter
Triggered when the HBA status
changes from Online to LINK
DOWN. Clears when the HBA status
returns to Online.
Alert (ID name)
18
Description
VMware, Inc.
Chapter 4 Management Pack for Storage Devices Alert Definitions
Table 4‑1. Management Pack for Storage Devices Alert Definitions (Continued)
Alert
Level
Affected Object
Type
HBA Speed dropped
(HostAdapterSpeedDropped)
Critical
Host Adapter
Triggered when the operating speed
of the host adapter drops compared
to a previous reading in the data
collection cycle.
Not automatically cleared. A user
must manually clear the alert.
High Virtual LUN Resets Or Aborts
(HighLunAbortsOrLunResets)
Critical
Mount
Triggered if 50 or more virtual LUN
resets or aborts occur per minute on
the mount object during two
consecutive collection cycles.
Clears when the LUN resets or
aborts drop to fewer than 50 per
minute for two consecutive
collection cycles.
IO Latency is above normal
(MountIoLatencyHigh)
Critical
Mount
Triggered if the
HostSpecificMetrics|IOLatency
metric exceeds the dynamic
threshold.
vRealize Operations Manager sets
the dynamic threshold based on the
historic data values of this metric.
Clears when the metric values fall
below the dynamic threshold.
Multiple ports on the Switch are down
(SwitchPortsDown)
Critical
Switch
Triggered when 50 percent or more
switch ports become disabled or
display the Enabled but offline
status.
Clears when the percentage of
unavailable switch ports falls below
50 percent.
No VASA providers registered to vCenter.
Cannot discover array objects
(NoVasaProvidersRegistered)
Warning
Storage Devices
Adapter Instance
Triggered when no VASA providers
are registered to the vCenter Server.
Clears when at least one VASA
provider is registered to the
vCenter Server.
Number of active paths is low
(PathHealthRatioLow)
Automatic
Mount
Triggered when the
HostSpecificMetrics|
PathHealthRatio metric for the
mount object falls below thresholds.
vRealize Operations Manager sets
the alert level based on the value of
pathHealthRatio:
n 75<=pathHealthRatio<100
indicates Immediate
n 50<=pathHealthRatio<75
indicates Warning
n pathHeathRatio< 50 indicates
Critical
Clears when pathHealthRatio value
becomes 100 for all the host system
instanced metric groups of the
mount object.
Alert (ID name)
VMware, Inc.
Description
19
vRealize Operations Management Pack for Storage Devices 6.0.3 Guide
Table 4‑1. Management Pack for Storage Devices Alert Definitions (Continued)
Alert
Level
Affected Object
Type
Permanent Device Loss on a Mount/Storage
LUN
(PDL)
Critical
VMWARE: Host
System
Triggered when one or more mounts
on the host system is unavailable.
This situation occurs if the
underlying storage LUN is
unmasked or removed from the host
system.
n If the storage LUN was
unmasked without first
detaching it from the host
system, the alert clears when the
mount object becomes available.
n If the storage LUN was
permanently removed, the alert
does not automatically clear. A
user must manually clear the
alert.
Some NFS volumes are not reachable from the
host because the physical NIC may be down
(APDOnNFSClientBecauseOfPnic)
Critical
VMWARE: Host
System
Triggered by an APD situation on
one or more Network File System
(NFS) volumes on the host system,
because the connected physical NIC
status is Down.
Clears when the APD situation is
resolved on the host system.
Some NFS volumes are not reachable from the
host because the switch port connecting to the
physical NIC on the host may be down
(APDOnNFSClientBecauseOfSwitchPort)
Critical
VMWARE: Host
System
Triggered by an APD situation on
one or more NFS volumes on the
host system because of the switch
port connected to the physical NIC is
Disabled.
Clears when the APD situation is
resolved on the host system.
Some NFS volumes are unreachable from the
host
(APDOnNFSClientGeneric)
Critical
VMWARE: Host
System
Triggered by a APD situation on one
or more NFS volumes on the host
system.
Clears when the APD situation is
resolved on the host system.
Storage LUN Thin Provisioned Capacity At
Critical Levels
(ThinProvisionedThresholdExceeded)
Critical
Storage LUN
Triggered when the thin
provisioning capacity on the storage
LUN reaches a critical level.
Thresholds for thin provisioning are
set in the vCenter Server.
Clears when the vCenter Server
sends the clear event to the
Management Pack for Storage
Devices.
Storage LUN Thin Provisioned Capacity
Threshold At Warning Level
(ThinProvisionedThresholdInitialized)
Warning
Storage LUN
Triggered when the thin
provisioning capacity on the storage
LUN reaches a warning level. The
thresholds for thin provisioning are
set in the vCenter.
Clears when the vCenter sends the
clear event to the
Management Pack for Storage
Devices.
Alert (ID name)
20
Description
VMware, Inc.
Chapter 4 Management Pack for Storage Devices Alert Definitions
Table 4‑1. Management Pack for Storage Devices Alert Definitions (Continued)
Alert
Level
Affected Object
Type
Switch Port Down Failure
(SwitchPortLinkDown)
Critical
Switch Port
Triggered when the status of switch
port changes to Disabled or Enabled
but Offline.
Clears when the switch port status
returns to Enabled.
VsanClusterPartitionedGeneric
Critical
VsanCluster
Triggered when the Virtual SAN
cluster is network partitioned and
not all Virtual SAN hosts in the
cluster can talk to each other due to
the absence of network connectivity.
Clears when the network
connectivity between all Virtual
SAN hosts in the cluster is restored.
VsanClusterPartitionedDueToPnic
Critical
VsanCluster
Triggered when the Virtual SAN
cluster is network partitioned
because the configured Physical
NICs on one or more hosts is not
available.
Clears when the network
connectivity between all the Virtual
SAN hosts in the cluster is restored.
VsanClusterPartitionedDueToSwitchPort
Critical
VsanCluster
Triggered when the Virtual SAN
cluster is network partitioned
because the configured network
switch ports on one or more IP
switches are not available.
Clears when the network
connectivity between all Virtual
SAN hosts in the cluster is restored.
VsanClusterPartitionedDueToMulticastIssue
Critical
VsanCluster
Triggered when the Virtual SAN
cluster is network partitioned
because the multicast addresses on
one or more NICs on Virtual SAN
hosts is not compatible with the rest
of the cluster.
Clears when all Virtual SAN hosts in
the cluster have compatible
multicast addresses.
VirtualSANHostComponentCountAlert
Automatic
HostSystem
Triggered when the number of
Virtual SAN components on a
Virtual SAN host exceeds 80 percent
of the maximum supported
components per host.
Clears when the number of Virtual
SAN components on a Virtual SAN
host is below 80 percent of the
maximum supported components
per host.
Alert (ID name)
VMware, Inc.
Description
21
vRealize Operations Management Pack for Storage Devices 6.0.3 Guide
Table 4‑1. Management Pack for Storage Devices Alert Definitions (Continued)
22
Alert (ID name)
Alert
Level
Affected Object
Type
HostSystemMagneticDiskDegraded
Critical
HostSystem
Triggered when the magnetic disk
reports a problem via SMART
status, when the bad sector count on
the magnetic disk is high, when
Virtual SAN reports degraded
components on the magnetic disk or
when the magnetic disk is
unreachable from the host.
Clears if the symptom disappears.
MagneticDiskCapacityWarning
Immediate
VsanDisk
Triggered when the Virtual SAN's
usage of the magnetic disk on the
host exceeds 80 percent of its
capacity.
Clears when the Virtual SAN's usage
of the magnetic disk on the host is
below 80 percent of its capacity.
HostSystemSSDDegraded
Automatic
HostSystem
Triggered when the SSD reports a
problem by using the SMART status
when the media wearout indicator
count on the SSD is high or when the
SSD is unreachable from the host.
Clears if the symptom disappears.
MagneticDiskReallocatedSectorsWarning
Warning
VsanDisk
Triggered when the bad sector count
on the magnetic disk is high.
Clears if the symptom disappears.
SSDMediaWearoutWarning
Warning
SSD
Triggered when the media wearout
indicator count on the SSD is high.
Clears if the symptom disappears.
VirtualSANHostHBAMissing
Critical
HostSystem
Triggered when the previously
discovered Virtual SAN storage
controller on a Virtual SAN host is
no longer accessible.
Clears when the Virtual SAN storage
controller is accessible.
VirtualSANHostMisconfiguredStorageAlert
Critical
HostSystem
Triggered when the Virtual SAN
host provides no storage to the
Virtual SAN datastore.
Clears when the Virtual SAN host
provides some storage to the Virtual
SAN datastore.
NetworkBandwidthCongestion
Critical
EsxPnic
Triggered when the physical NICs
on ESXi host are saturated with the
network traffic.
Clears when the physical NICs on
ESXi host are not saturated with the
network traffic.
Description
VMware, Inc.
Chapter 4 Management Pack for Storage Devices Alert Definitions
Table 4‑1. Management Pack for Storage Devices Alert Definitions (Continued)
Alert (ID name)
Alert
Level
Affected Object
Type
spbmVsanProfileIncompatible3
Critical
VirtualMachine
Triggered when the virtual machines
are not compliant with their
specified storage profile.
Cleared when the virtual machines
are compliant with their specified
storage profile.
VsanComponentsNotActiveForVM
Warning
VirtualMachine
Triggered when some Virtual SAN
components are not active for a
virtual machine. This could indicate
a possible performance degradation
of the virtual machine.
Clears when the inactive
components on the virtual machine
are removed or are active again.
VMware, Inc.
Description
23
vRealize Operations Management Pack for Storage Devices 6.0.3 Guide
24
VMware, Inc.
Management Pack for Storage
Devices Metrics
5
The Management Pack for Storage Devices collects metrics for objects. It also displays object properties in
the vRealize Operations Manager user interface.
This chapter includes the following topics:
n
“Statistical Metrics of the Management Pack for Storage Devices,” on page 25
n
“Object Properties,” on page 33
Statistical Metrics of the Management Pack for Storage Devices
The Management Pack for Storage Devices collects statistical metrics of objects.
You can view these metrics from the vRealize Operations Manager user interface. From the vRealize
Operations Manager user interface, click Environment > Storage Devices > Troubleshooting > All Metrics
tab .
Disk Group Metrics
The Management Pack for Storage Devices collects metrics about disk groups.
Table 5‑1. Disk Group Metrics
Metric Name
User Interface Name
DerivedStatistics.DiskGroupCapacity
Disk Group Capacity
DerivedStatistics.DiskGroupDemand
Disk Group Demand
DerivedStatistics.DiskGroupUsage
Disk Group Usage
VsanStatistics.Disk Capacity (GB)
Disk Capacity (GB)
VsanStatistics.Disk Capacity Used (%)
Disk Capacity Used (%)
VsanStatistics.Capacity Used (GB)
Capacity Used (GB)
ESXi Physical NIC Metrics
The Management Pack for Storage Devices collects metrics about the physical Network Interface Cards
(NICs) on the ESXi host.
Table 5‑2. ESXi Physical NIC Metrics
Metric Name
User Interface Name
esx_pnic_statistics.PacketsReceived
Packets Received
esx_pnic_statistics.PacketsTransmitted
Packets Transmitted
VMware, Inc.
25
vRealize Operations Management Pack for Storage Devices 6.0.3 Guide
Table 5‑2. ESXi Physical NIC Metrics (Continued)
Metric Name
User Interface Name
esx_pnic_statistics.Received
Received
esx_pnic_statistics.Transmitted
Transmitted
esx_pnic_statistics.DroppedReceived
Dropped Received
esx_pnic_statistics.DroppedTransmitted
Dropped Transmitted
esx_pnic_statistics.BytesReceived
Bytes Received
esx_pnic_statistics.BytesTransmitted
Bytes Transmitted
esx_pnic_statistics.BroadcastReceived
Broadcast Received
esx_pnic_statistics.BroadcastTransmitted
Broadcast Transmitted
DerivedStatistics.Capacity
Capacity (MBps)
DerivedStatistics.Demand
Demand (MBps)
DerivedStatistics.Usage
Usage (MBps)
DerivedStatistics.UsageCapacityPercent
Used Capacity Percent
Host Adapter Metrics
The Management Pack for Storage Devices collects metrics about the host adapters in the host system.
Table 5‑3. Host Adapter Metrics
Metric Name
User Interface Name
Fiber Channel Metrics
26
adapter_performance_metrics.outstandingIOs
Storage Adapter Outstanding I/Os
adapter_performance_metrics.queueDepth
Storage Adapter Queue Depth
adapter_performance_metrics.queueLatency
Storage Adapter Queue Command Latency
adapter_performance_metrics.queued
Storage Adapter Number Queued
adapter_performance_metrics.read
Reads Per Sec
ReadStatistics.BlocksRead
Blocks Read Per Second
ReadStatistics.ReadOperations
Read Operations Per Second
WriteStatistics.BlocksWritten
Blocks Written Per Second
WriteStatistics.WriteOperations
Write Operations Per Second
TaskManagementStatistics.Aborts
Aborts Per Minute
TaskManagementStatistics.LunResets
Lun Resets Per Minute
DerivedStatistics.CongestionRatio
Congestion Ratio
DerivedStatistics.IOPs
Aggregation of the read and write operations per second.
DerivedStatistics.HostAdapterCapacity
Host Adapter Capacity (MBps)
DerivedStatistics.HostAdapterDemand
Host Adapter Demand (MBps)
DerivedStatistics.HostAdapterUsage
Host Adapter Usage (MBps)
DerivedStatistics.HostAdapterInferredLatency
Input/Output latency observed on the host adapter.
AdapterErrorStatistics.FailedCommands
Failed Commands
AdapterErrorStatistics.FailedBlocksRead
Failed Blocks Read Per Second
AdapterErrorStatistics.FailedBlocksWritten
Failed Blocks Written Per Second
VMware, Inc.
Chapter 5 Management Pack for Storage Devices Metrics
Table 5‑3. Host Adapter Metrics (Continued)
Metric Name
User Interface Name
AdapterErrorStatistics.FailedReadOperations
Failed Read Operations Per Second
AdapterErrorStatistics.FailedWriteOperations
Failed Write Operations Per Second
AdapterErrorStatistics.LipCount
Lip Count
AdapterErrorStatistics.ErrorFrames
Error Frames Per Second
AdapterErrorCountPerMin.LinkFailureCount
Link Failure Count
AdapterErrorCountPerMin.LossOfSignalCount
Loss Of Signal Count
AdapterErrorCountPerMin.InvalidTxWordCount
Invalid Tx Word Count
AdapterErrorCountPerMin.InvalidCRCCount
Invalid CRC Count
adapter_performance_metrics.commandsAveraged
Commands Averaged
adapter_performance_metrics.numberReadAveraged
Number Read Averaged
adapter_performance_metrics.numberWriteAveraged
Number Write Averaged
adapter_performance_metrics.totalReadLatency
Read latency
adapter_performance_metrics.totalWriteLatency
Write latency
adapter_performance_metrics.write
Writes per sec
FCStatistics.TxFrames
Tx Frames Per Second
FCStatistics.RxFrames
Rx Frames Per Second
Local Storage Controller Metrics
DerivedStatistics.HostAdapterCapacity
Host Adapter Capacity (MBps)
DerivedStatistics.HostAdapterDemand
Host Adapter Demand (MBps)
DerivedStatistics.HostAdapterUsage
Host Adapter Usage (MBps)
DerivedStatistics.HostAdapterInferredLatency
Input/Output latency observed on the host adapter.
AdapterErrorStatistics and AdapterErrorCountPerMin metrics are displayed only in Fibre Channel (FC)
and Fibre Channel over Ethernet (FCoE) environments.
Magnetic Disk Metrics
The Management Pack for Storage Devices collects magnetic disk metrics about the about the Virtual SAN
datastores in your datacenter.
Table 5‑4. Magnetic Disk Metrics
Metric Name
User Interface Name
VsanStatistics.failedCommands
Failed Commands
VsanStatistics.latency.totalTime
Latency total time
VsanStatistics.capacityUsed
Disk Capacity Used (%)
VMware, Inc.
27
vRealize Operations Management Pack for Storage Devices 6.0.3 Guide
Magnetic Disk, Solid State Device, and Disk Group Metrics
The Management Pack for Storage Devices collects metrics about the magnetic disks, solid state devices, and
disk groups on the ESXi hosts.
Table 5‑5. Magnetic Disk, Solid State Device, and Disk Group Metrics
Metric Name
User Interface Name
busResets
Bus Resets
commandsAborted
Commands Aborted
deviceLatency
Device Latency
deviceReadLatency
Device Read Latency
deviceWriteLatency
Device Write Latency
numberRead
Number Read
numberReadAveraged
Number Read Averaged
numberWrite
Number Write
numberWriteAveraged
Number Write Averaged
Read Rate
Read rate
scsiReservationConflicts
NOTE This metric is applicable only to fibre channel
mounts.
SCSI Reservation Conflicts
totalLatency
Total Latency
totalReadLatency
Total Read Latency
totalWriteLatency
Total Write Latency
Write Rate
Write Rate
HDDErrors
HDD Errors
IOPS
NOTE This metric is applicable only to magnetic disks.
IOPS
Magnetic Disk and Solid State Device Smart Metrics
The Management Pack for Storage Devices collects SMART metrics about magnetic disks and solid state
devices on the ESXi hosts.
Table 5‑6. Magnetic Disk and Solid State Device SMART Metrics
28
Metric Name
User Interface Name
scsi_smart_statistics.HealthStatus.Value
Health Status Value
scsi_smart_statistics.MediaWearoutIndicator.Value
Media Wearout Indicator Value
scsi_smart_statistics.MediaWearoutIndicator.Threshold
Media Wearout Indicator Threshold
scsi_smart_statistics.WriteErrorCount.Value
Write Error Count Value
scsi_smart_statistics.WriteErrorCount.Threshold
Write Error Count Threshold
scsi_smart_statistics.ReadErrorCount.Value
Read Error Count Value
scsi_smart_statistics.ReadErrorCount.Threshold
Read Error Count Threshold
scsi_smart_statistics.PoweronHours.Value
Power on Hours value
scsi_smart_statistics.ReallocatedSectors.Value
Re-allocated sectors value
VMware, Inc.
Chapter 5 Management Pack for Storage Devices Metrics
Table 5‑6. Magnetic Disk and Solid State Device SMART Metrics (Continued)
Metric Name
User Interface Name
scsi_smart_statistics.ReallocatedSectors.Threshold
Re-allocated sectors threshold
scsi_smart_statistics.RawReadErrorRate.Value
Raw Read Error Rate Value
scsi_smart_statistics.RawReadErrorRate.Threshold
Raw Read Error Rate Threshold
scsi_smart_statistics.DriveTemperature.Value
Drive Temperature Value
scsi_smart_statistics.DriveTemperature.Worst
Drive Temperature Worst
scsi_smart_statistics.DriveTemperature.Threshold
Drive Temperature Threshold
scsi_smart_statistics.DriveRatedMaxTemperature.Value
Drive Rated Max Temperature Value
scsi_smart_statistics.DriveRatedMaxTemperature.Threshold
Drive Rated Max Temperature Threshold
scsi_smart_statistics.WriteSectorsTOTCount.Value
Write Sectors TOT Count Value
scsi_smart_statistics.WriteSectorsTOTCount.Threshold
Write Sectors TOT Count Threshold
scsi_smart_statistics.ReadSectorsTOTCount.Value
Read Sectors TOT Count Value
scsi_smart_statistics.ReadSectorsTOTCount.Threshold
Read Sectors TOT Count Threshold
scsi_smart_statistics.InitialBadBlockCount.Value
Initial Bad Block Count Value
scsi_smart_statistics.InitialBadBlockCount.Threshold
Initial Bad Block Count Threshold
Mount Metrics
The Management Pack for Storage Devices collects metrics about a storage LUN abstraction that is available
on the host system.
Table 5‑7. Mount Metrics
Metric Name
User Interface Name
DeviceErrorStatistics.FailedCommands
Failed Commands
DeviceErrorStatistics.FailedReadOperations
Failed Read Operations
DeviceErrorStatistics.FailedWriteOperations
Failed Write Operations
DeviceErrorStatistics.FailedBlocksWritten
Failed Blocks Written
ReadStatistics.BlocksRead
Blocks Read
ReadStatistics.ReadOperations
Read Operations
WriteStatistics.BlocksWritten
Blocks Written
WriteStatistics.WriteOperations
Write Operations
TaskManagementStatistics.Aborts
Task Management Statistics
TaskManagementStatistics.LunResets
LUN Resets
DerivedStatistics.CongestionRatio
Ratio of the active commands to the queued commands on
the mount.
HostSpecificMetrics.PathHealthRatio
Path Health Ratio
DerivedStatistics.MountCapacity
Mount Throughput Capacity (MBps)
DerivedStatistics.MountDemand
Mount Throughput Demand (MBps)
DerivedStatistics.MountUsage
Mount Throughput Usage (MBps)
DerivedStatistics.MountInferredLatency
Mount Inferred Latency
DerivedStatistics.MountAggregatedErrors
Mount errors
DerivedStatistics.IOPS
IOPS
VMware, Inc.
29
vRealize Operations Management Pack for Storage Devices 6.0.3 Guide
Table 5‑7. Mount Metrics (Continued)
Metric Name
User Interface Name
The following metrics are relevant only for ISCSI Mounts
DiskStatistics.busResets
Bus resets
DiskStatistics.capacity.contention
Capacity contention on mount
DiskStatistics.capacity.provisioned
Capacity provisioned on mount
DiskStatistics.capacity.usage
Capacity used on mount
DiskStatistics.commands
Commands on mount
DiskStatistics.commandsAborted
Aborted Commands on mount
DiskStatistics.commandsAveraged
Average number of commands on mount
DiskStatistics.deviceLatency
Latency
DiskStatistics.deviceReadLatency
Read Latency
DiskStatistics.deviceWriteLatency
Write Latency
DiskStatistics.maxQueueDepth
Maximum Queue Depth on Mount
DiskStatistics.maxTotalLatency
Max latency seen on mount
DiskStatistics.numberRead
Number of reads
DiskStatistics.numberWrite
Number of writes
DiskStatistics.queueLatency
Queued Latency
DiskStatistics.read
Read Throughput
DiskStatistics.scsiReservationConflicts
Number of SCSI Reservation Conflicts
DiskStatistics.totalLatency
Kernel Latency + Device Latency
DiskStatistics.write
Write Throughput
NFS Volume Metrics
The Management Pack for Storage Devices collects metrics about Network File System (NFS) volumes.
Table 5‑8. NFS Volume Metrics
30
Metric Name
User Interface Name
DerivedStatistics.ThroughputCapacity
Throughput (MBps)
DerivedStatistics.ThroughputUsage
Current Throughput (MBps)
DerivedStatistics.InferredLatency
Inferred Latency
NfsVolumePerformanceMetrics.datastoreIops
Aggregate IOPS
NfsVolumePerformanceMetrics.datastoreWriteIops
Writes per second
NfsVolumePerformanceMetrics.read
Read Rate
NfsVolumePerformanceMetrics.write
Write Rate
NfsVolumePerformanceMetrics.totalReadLatency
Total Read Latency
NfsVolumePerformanceMetrics.datastoreReadBytes
Bytes Read
NfsVolumePerformanceMetrics.datastoreWriteBytes
Bytes Written
NfsVolumePerformanceMetrics.datastoreReadIops
Reads per second
NfsVolumePerformanceMetrics.totalWriteLatency
Total Write Latency
VMware, Inc.
Chapter 5 Management Pack for Storage Devices Metrics
Solid State Devices Metrics
The Management Pack for Storage Devices collects solid state devices metrics about the about the Virtual
SAN datastores in your datacenter.
Table 5‑9. Solid State Devices Metrics
Metric Name
User Interface Name
VsanStatistics.failedCommands
Failed Commands
VsanStatistics.latency.totalTime
Latency total time
VsanStatistics.Read Cache Hit Rate (%)
Read Cache Hit Rate (%)
Storage LUN Metrics
The Management Pack for Storage Devices collects metrics about the storage LUN of a storage array.
Table 5‑10. Storage LUN Metrics
Metric Name
User Interface Name
lun.PercentUsed
Percent Used
lun.LunCapacity
LUN Capacity
Switch Port Metrics
The Management Pack for Storage Devices collects metrics about the port on a switch.
Table 5‑11. Switch Port Metrics
Metric Name
User Interface Name
switch_port_statistics.AddressErrors
Address Errors
switch_port_statistics.BytesReceived
Bytes Received
switch_port_statistics.BytesTransmitted
Bytes Transmitted
switch_port_statistics.CRCErrors
CRC Errors
switch_port_statistics.DelimiterErrors
Delimiter Errors
switch_port_rate_statistics.RxFrameRate
Rx Frame Rate
switch_port_rate_statistics.RxRate
Rx Rate
switch_port_rate_statistics.TxFrameRate
Tx Frame Rate
switch_port_rate_statistics.TxRate
Tx Rate
DerivedStatistics.SwitchPortCapacity
Switch Port Capacity (MBps)
DerivedStatistics.SwitchPortUsage
Switch Port Capacity
DerivedStatistics.AggregatedErrors
Aggregated switch port error count including address
errors, CRC errors, and delimiter errors.
VMware, Inc.
31
vRealize Operations Management Pack for Storage Devices 6.0.3 Guide
Virtual SAN Datastore (Performance Metrics)
The Management Pack for Storage Devices collects performance metrics about the Virtual SAN datastores in
your datacenter.
Table 5‑12. Virtual SAN Datastore (Performance Metrics)
Metric Name
User Interface Name
PerformanceStatistics.opIngressCongestionCount
opIngressCongestionCount
PerformanceStatistics.readCachedBytes
Total Read Cached Bytes
PerformanceStatistics.readCachedCount
Read Cached Count
PerformanceStatistics.writeCongestionSum
Write Congestion Sum
PerformanceStatistics.recoveryWriteCount
Total Recovery Write Count
PerformanceStatistics.readCount
Total Read Count
PerformanceStatistics.recoveryWriteBytes
Recovery Write Bytes
PerformanceStatistics.writeBytes
Total Write Bytes
PerformanceStatistics.recoveryWriteCongestionSum
Recovery Write Congestion Sum
PerformanceStatistics.prepareLimitRetryCount
Prepare Limit Retry Count
PerformanceStatistics.readCachedLatencyMaxUs
Maximum Read Cached Latency (ms)
PerformanceStatistics.readCongestionSum
Total Read Congestion
PerformanceStatistics.ioCount
Total Input Output Count
PerformanceStatistics.objIngressCongestionCount
Object Ingress Congestion Count
PerformanceStatistics.recoveryWriteLatencyMaxUs
Maximum Recovery Write Latency (ms)
PerformanceStatistics.writeLatencyMaxUs
Maximum Write Latency (ms)
PerformanceStatistics.writeCount
Total Write Count
PerformanceStatistics.readLatencyMaxUs
Maximum Read Latency (ms)
PerformanceStatistics.readCachedCongestionSum
Total Read Cached Congestion
Virtual SAN Datastore Metrics
The Management Pack for Storage Devices collects metrics about the Virtual SAN datastores in your
datacenter.
Table 5‑13. Virtual SAN Datastore Metrics
32
Metric Name
User Interface Name
DerivedStatistics.totalCapacity
Total Capacity (MB)
DerivedStatistics.provisionedCapacity
Demand (MB)
DerivedStatistics.usedCapacity
Usage (MB)
DerivedStatistics.latency
Inferred Latency
DerivedStatistics.throughput
Throughput (MBps)
DerivedStatistics.maxThroughput
Maximum Throughput (MBps)
DerivedStatistics.avgTotalCapacityPerDiskGroup
Average Capacity Per Disk Group (GB)
DerivedStatistics.avgUsedCapacityPerDiskGroup
Average Used Capacity Per Disk Group (GB)
DerivedStatistics.avgThroughputPerDiskGroup
AverageThroughput Per Disk Group (MBps)
VMware, Inc.
Chapter 5 Management Pack for Storage Devices Metrics
Table 5‑13. Virtual SAN Datastore Metrics (Continued)
Metric Name
User Interface Name
DerivedStatistics.avgMaxThroughputPerDiskGroup
Average Max Throughput Per Disk Group (MBps)
HostSpecificMetrics.readCachedLatency
Read Cached Latency (ms)
HostSpecificMetrics.readLatency
Read Latency (ms)
HostSpecificMetrics.recoveryWriteLatency
Recovery Write Latency (ms)
HostSpecificMetrics.writeLatency
Write Latency (ms)
HostSpecificMetrics.PerHostThroughput
Throughput (KBps)
HostSpecificMetrics.MaxPerHostThroughput
Maximum Throughput (KBps)
Virtual SAN Host Metrics
The Management Pack for Storage Devices collects metrics about the Virtual SAN host in your datacenter.
Table 5‑14. Virtual SAN Host Metrics
Metric Name
User Interface Name
VsanStatistics.ComponentUsage
Component usage (%)
VsanStatistics.capacity
Capacity (GB)
VsanStatistics.totalUsedCapacity
Capacity Used (GB)
DerivedStatistics.ThroughputCapacity
Throughput (MBps)
DerivedStatistics.ThroughputUsage
Current Throughput (MBps)
Object Properties
The Management Pack for Storage Devices displays object properties.
You can view the object properties from the vRealize Operations Manager user interface. From the vRealize
Operations Manager user interface, click Environment > Storage Devices > Analysis tab.
Disk Group Properties
The Management Pack for Storage Devices displays the disk group object properties.
Table 5‑15. Disk Group Properties
Name
Type
Display Name
Description
HostUuid
String
Host UUID
The UUID of the host.
ESXi Physical Network Interface Card Properties
The Management Pack for Storage Devices displays the properties of the ESXi Physical Network Interface
Card (NIC) object.
Table 5‑16. ESXi Physical NIC Properties
Name
Type
Display Name
Description
Link Speed
long
Link Speed
The speed of the link.
Link State
string
Link State
Indicates the state of the
link.
VMware, Inc.
33
vRealize Operations Management Pack for Storage Devices 6.0.3 Guide
Table 5‑16. ESXi Physical NIC Properties (Continued)
Name
Type
Display Name
Description
PCI Device
string
PCI Device
Indicates the type of PCI
used.
Driver Name
string
Driver Name
Indicates the name of the
driver.
Host Adapter Properties
The Management Pack for Storage Devices displays the properties of the host adapter.
Table 5‑17. Host Adapter Properties
Name
Type
Display
Name
FirmwareVersion
string
Firmware Version
The host bus adapter (HBA) firmware version.
DriverName
string
Driver Name
The HBA driver name in ESXi.
DriverVersion
string
Driver Version
The HBA drvier version in ESXi.
PortSpeed
string
Port Speed
The configured port speed.
SupportedPortSpeeds
string
Supported Port
Speeds
The list of supported port speeds.
Vendor
string
Vendor
The vendor's name for the HBA.
Model
string
Model
The model name of the HBA.
HostPortName
string
Host Port Name
The World Wide Port Name (WWPN) of the HBA.
HostNodeName
string
Host Node Name
The World Wide node name of the HBA.
HardwareVersion
string
Hardware Version
The hardware version of the HBA.
OptionROMVersion
string
Option ROM
Version
The read-only memory of the HBA.
MaxFrameSize
string
Max Frame Size
The maximum size of a frame.
PortType
string
Port Type
The port type such as N port and F port.
FabricName
string
Fabric Name
The WWPN of the fabric the HBA connects.
Name
string
Name
The HBA name in ESXi.
IP Switch Properties
The Management Pack for Storage Devices displays the properties of the IP switch objects.
Table 5‑18. IP Switch Properties
34
Name
Type
Display Name
Description
SNMP Enabled
string
SNMP Enabled
Indicates if the IP switch is
SNMP enabled.
VMware, Inc.
Chapter 5 Management Pack for Storage Devices Metrics
IP Switch Port Properties
The Management Pack for Storage Devices displays the properties of the IP switch port object.
Table 5‑19. IP Switch Port Properties
Name
Type
Display Name
Description
Port State
string
Port State
Indicates the state of the
port.
Storage Array Properties
The Management Pack for Storage Devices displays the properties of the storage array object.
Table 5‑20. Storage Array Properties
Name
Type
Display Name
Description
Firmware
string
Storage Array Firmware
The firmware version of the
array.
ModelId
string
Storage Array Model Id
The model number.
VendorId
string
Vendor ID
The vendor identifier.
SupportedBlockInterfaces
string
Supported Block Interfaces
The list of supported block
interfaces like Fibre Channel
(FC) and iSCSI.
SupportedFileSystemInterf
aces
string
Supported File System Interfaces
The list of supported file system
interfaces like Network File
System (NFS) and Common
Internet File System (CIFS).
Name
string
Array Name
The array name.
UUID
string
SMS Array Uuid
The UUID of the array.
AlternateNames
string
Alternate Names
-
SupportedProfile
string
Supported Profile
The list of supported VASA
profiles.
Magnetic Disk Properties
The Management Pack for Storage Devices displays the properties of the magnetic disk object.
Table 5‑21. Magnetic Disk Properties
Name
Type
Display Name
Description
Name
string
Name
The name of the magnetic disk.
Size
string
Size
The size of the magnetic disk.
Vendor
string
Vendor
The name of the manufacturer of the magnetic
disk.
is Virtual SAN Entity
string
is Virtual SAN Entity
Indicates if the component is part of a Virtual
SAN cluster.
QueueDepth
string
Queue Depth
The number of pending input/output requests.
VsanStatistics.capacity
numeric
Disk Capacity (GB)
Magnetic disk capacity in GB.
maxQueueDepth
numeric
Max Queue Depth
Maximum queue depth sustained by the magnetic
disk.
VMware, Inc.
35
vRealize Operations Management Pack for Storage Devices 6.0.3 Guide
Mount Properties
TheManagement Pack for Storage Devices displays the properties of the mount object.
Table 5‑22. Mount Properties
Name
Type
Display Name
Description
Vendor
string
Vendor
The vendor name of the mount device.
Model
string
Model
The number of the mount device.
Size
long
Mount Size in KB
The capacity of the mount device.
Name
string
Name
The device identifier of the mount
device.
Solid State Device Properties
The Management Pack for Storage Devices displays the properties of the solid state device object.
Table 5‑23. Solid State Device Properties
Name
Type
Display Name
Description
Name
string
Name
The name of the solid state
device.
Size
string
Size
The size of the solid state
device.
Vendor
string
Vendor
The name of the
manufacturer of the solid
state device.
is Virtual SAN Entity
string
is Virtual SAN Entity
Indicates if the component is
part of a Virtual SAN
cluster.
QueueDepth
string
QueueDepth
The number of pending
input/output requests.
Switch Properties
The Management Pack for Storage Devices displays the properties of the switch object.
Table 5‑24. Switch Properties
36
Name
Type
Display Name
Description
Manufacturer
string
Manufacturer
The name of the
manufacturer of the switch.
Model
string
Model
The model of the switch.
PartNumber
string
Part Number
The part number of the
switch.
SerialNumber
string
Serial Number
The serial number of the
switch.
ManufacturerSerialNumber
string
Manufacturer Serial Number
The serial number of the
manufacturer of the switch.
VersionString
string
Version String
The version number.
ClassificationDescriptions
string
Classification Descriptions
The version class (operating
system and firmware).
VMware, Inc.
Chapter 5 Management Pack for Storage Devices Metrics
Switch Port Properties
The Management Pack for Storage Devices displays the properties of the switch port object.
Table 5‑25. Switch Port Properties
Name
Type
Display Name
Description
Speed
long
Speed
The configured speed.
MaxSpeed
long
Max Speed
The maximum speed.
PortType
string
Port Type
The type of port.
PortNumber
string
Port Number
The port number.
PermanentAddress
string
Permanent Address
The WWPN of the switch
port.
EnabledState
string
Enabled State
Indicates if the port is
enabled.
VMware, Inc.
37
vRealize Operations Management Pack for Storage Devices 6.0.3 Guide
38
VMware, Inc.
User Scenario: An Object in Your
Storage Network Has a Performance
Problem
6
A user reports that a virtual machine is running slow. She is not sure how long the problem has existed, but
needs to process data overnight and wants to know if she can start the task before she leaves for the day.
As the system administrator, you realize that the problem might not be with the virtual machine itself.
Rather than investigate the state of only the virtual machine, you begin by reviewing the dashboard that
shows the state of all storage network objects associated with the virtual machine.
Procedure
1
See the topic called User Scenario: Use the Troubleshooting Dashboard to Locate the Real Problem
Source
As the system administrator for the data center, you must locate the user's virtual machine in the
network storage topology so that you can determine if the problem is with the host system or
somewhere else in the storage network.
2
See the topic called User Scenario: Examine Metrics to Find the Root Cause
To determine if the virtual machine performance problem is temporary or indicates a more serious
problem in the storage network, you create metric charts to identify the root cause of the problem.
This chapter includes the following topics:
n
“User Scenario: Use the Troubleshooting Dashboard to Locate the Real Problem Source,” on page 39
n
“User Scenario: Examine Metrics to Find the Root Cause,” on page 40
User Scenario: Use the Troubleshooting Dashboard to Locate the
Real Problem Source
As the system administrator for the data center, you must locate the user's virtual machine in the network
storage topology so that you can determine if the problem is with the host system or somewhere else in the
storage network.
The fastest way to inspect all of the components connected to the virtual machine is to look at the
Troubleshooting dashboard. Start by locating the problematic object.
Procedure
1
Click the Troubleshooting dashboard.
The dashboard displays badges for all the objects that the Management Pack for Storage Devices
discovered in the storage area network.
2
VMware, Inc.
In the group of virtual machines displayed, point to each badge icon to see the object name.
39
vRealize Operations Management Pack for Storage Devices 6.0.3 Guide
3
Identify the virtual machine that the user reported as slow and select the badge.
This action highlights all the objects in the storage area network path from the host system to the
storage mount that are associated with the virtual machine.
4
Review highlighted objects that appear with a red, orange, or yellow condition.
5
Select an object to inspect problems or alerts reported in the widgets on the right.
Problems such as low throughput do not generate alerts but can affect performance.
You identified storage components associated with the virtual machine that have problems. You can now
select one of the components to examine faults, anomalies, and metrics on that object and determine if its
problems are the root cause of problems seen on the virtual machine.
User Scenario: Examine Metrics to Find the Root Cause
To determine if the virtual machine performance problem is temporary or indicates a more serious problem
in the storage network, you create metric charts to identify the root cause of the problem.
You used the Troubleshooting dashboard to find an object networked to the problematic virtual machine
that is not operating at an optimum. Now you want to investigate the performance of that object over a
period of time.
Procedure
1
If you are on the Troubleshooting dashboard with the problematic virtual machine selected, select a
highlighted object that appears with a red, orange, or yellow condition.
2
Double-click the object to access collected metrics.
The left pane displays the object name and the related objects. The main pane displays the Summary
tab.
3
Click the Troubleshooting tab, and click the All Metrics tab.
Throughput, latency, and error metrics are the most useful troubleshooting metrics.
a
Select the error statistics and double-click an entry to determine if errors occurred over time. Errors
can indicate when the component had trouble accessing the network.
b
Select the derived statistics and double-click the use to see a historical graph of the component use
over time. Slow throughput can occur during times of high workload.
c
Select the derived statistics and double-click the latency to see a historical graph of the time
required to process IO requests. High latency can indicate that the component had trouble
receiving data from the network.
What to do next
If the error statistics show no problems and derived statistics show a cyclical use pattern on the component,
you can call the user and explain that the problem might be temporary and when IO traffic throughout the
network drops, the virtual machine will become more responsive.
If the error statistics show no problems and derived statistics show consistently low use of the component
but the latency is suddenly high, another component on the network might be causing connectivity to time
out. Check for a faulty switch or other faulty component on the network.
40
VMware, Inc.
Index
A
O
about 5
add credentials for a storage device 10
add fabric servers for the management pack for
storage devices 10
alert definitions, Storage Devices 17
object properties 33
D
dashboards 15
disk group properties 33
disk group metrics 25, 28
E
ESXi physical NIC 25
ESXi Physical NIC properties 33
H
host adapter metrics 26
host adapter properties 34
I
install 9
installing and configuring 9
intended audience 5
introduction 7
investigate details, storage network
component 40
IP switch 34
IP switch port 35
M
magnetic disk metrics 27
magnetic disk properties 35
magnetic disk SMART metrics 28
magnetic disks metrics, magnetic disk
metrics 28
management pack 9
metrics, solid state device metrics 28
mount metrics 29
mount properties 36
P
ports and log files 13
S
solid state device properties 36
Solid State Device SMARTmetrics 28
solid state devices metrics 31
statistical metrics 25
storage devices
verify connection 12
verify data collection 12
storage array properties 35
storage Devices, alert definitions 17
storage LUN metrics 31
storage network component
investigate details 40
troubleshoot 39
troubleshooting dashboard 39
switch port metrics 31
switch port properties 37
switch properties 36
T
troubleshoot, storage network component 39
troubleshooting dashboard, storage network
component 39
V
verify connection, storage devices 12
verify data collection, storage devices 12
virtual SAN datastore metrics 32
virtual SAN datastore (performance metrics) 32
virtual SAN host metrics 33
N
NFS volume metrics 30
VMware, Inc.
41
vRealize Operations Management Pack for Storage Devices 6.0.3 Guide
42
VMware, Inc.