MAX6323/MAX6324 µP Supervisory Circuits with Windowed (Min/Max) Watchdog and Manual Reset General Description
... The MAX6323/MAX6324 µP supervisory circuits maintain system integrity by alerting the µP to fault conditions. In addition to a standard V CC monitor (for power-on reset, brownout detect, and power-down reset), the devices include a sophisticated watchdog timer that detects when the processor is runn ...
... The MAX6323/MAX6324 µP supervisory circuits maintain system integrity by alerting the µP to fault conditions. In addition to a standard V CC monitor (for power-on reset, brownout detect, and power-down reset), the devices include a sophisticated watchdog timer that detects when the processor is runn ...
100327DRFSinLCWS.Beijin10
... for a group of 13 units of klystrons are provided by one common DC power supply and one common anode modulator (MA modulator). • In order to realize high reliability, each of the DC power supplies and MA modulators is associated with one backup units, which will be designed and implemented to be “ho ...
... for a group of 13 units of klystrons are provided by one common DC power supply and one common anode modulator (MA modulator). • In order to realize high reliability, each of the DC power supplies and MA modulators is associated with one backup units, which will be designed and implemented to be “ho ...
MAX13046E/MAX13047E Single- and Dual-Bidirectional Low-Level Translator General Description
... dual-channel translator. Externally applied voltages, VCC and VL, set the logic level on either side of the device. The MAX13046E/MAX13047E utilize a transmission-gate-based design to allow data translation in either direction (VL↔VCC) on any single data line. The MAX13046E/MAX13047E accept VL from ...
... dual-channel translator. Externally applied voltages, VCC and VL, set the logic level on either side of the device. The MAX13046E/MAX13047E utilize a transmission-gate-based design to allow data translation in either direction (VL↔VCC) on any single data line. The MAX13046E/MAX13047E accept VL from ...
3-5 I/O Specifications
... systems which, in the event of failure, can lead to loss of human life. ◊ If you intend to use the modules covered in these operating instructions for special applications, such as for nuclear energy control, aerospace, medical, or transportation, please consult your Fuji Electric agent. ◊ Be sure t ...
... systems which, in the event of failure, can lead to loss of human life. ◊ If you intend to use the modules covered in these operating instructions for special applications, such as for nuclear energy control, aerospace, medical, or transportation, please consult your Fuji Electric agent. ◊ Be sure t ...
Instruction Manual • Authorized Electricians blueplanet
... The PV array comprises individual PV circuits, with each circuit containing one positive and one negative contributor. The individual PV circuits are connected in parallel at a DC circuit termination point. The DC circuits can be terminated either outside the inverter, or inside the inverter as show ...
... The PV array comprises individual PV circuits, with each circuit containing one positive and one negative contributor. The individual PV circuits are connected in parallel at a DC circuit termination point. The DC circuits can be terminated either outside the inverter, or inside the inverter as show ...
PL 3120®/PL 3150®/PL 3170
... Echelon, LON, LONWORKS, i.LON, LonBuilder, NodeBuilder, LNS, LonTalk, Neuron, 3120, 3150, LonMaker, ShortStack, and the Echelon logo are trademarks of Echelon Corporation registered in the United States and other countries. 3170 is a trademark of Echelon Corporation. Other brand and product names a ...
... Echelon, LON, LONWORKS, i.LON, LonBuilder, NodeBuilder, LNS, LonTalk, Neuron, 3120, 3150, LonMaker, ShortStack, and the Echelon logo are trademarks of Echelon Corporation registered in the United States and other countries. 3170 is a trademark of Echelon Corporation. Other brand and product names a ...
PowerFlex 700H and 700S AC Drives, Frames 9...14 Installation
... operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Activities including installation, adjustment ...
... operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Activities including installation, adjustment ...
MAX 10 FPGA Device Family Pin Connection Guidelines
... www.altera.com/common/legal.html. Intel warrants performance of its semiconductor products to current specifications in accordance with Altera’s standard warranty, but reserves the right to make changes to any products and services at any time without notice. Intel assumes no responsibility or liabi ...
... www.altera.com/common/legal.html. Intel warrants performance of its semiconductor products to current specifications in accordance with Altera’s standard warranty, but reserves the right to make changes to any products and services at any time without notice. Intel assumes no responsibility or liabi ...
Hall Effect Sensing and Application
... The Hall effect has been known for over one hundred years, but has only been put to noticeable use in the last three decades. The first practical application (outside of laboratory experiments) was in the 1950s as a microwave power sensor. With the mass production of semiconductors, it became feasib ...
... The Hall effect has been known for over one hundred years, but has only been put to noticeable use in the last three decades. The first practical application (outside of laboratory experiments) was in the 1950s as a microwave power sensor. With the mass production of semiconductors, it became feasib ...
NE02 Brochure
... Molded case circuit breakers typically have lower single-pole interrupting capabilities than their multi-pole interrupting rating. See discussion for section 240.85 on slash ratings and single pole interrupting capabilities. How does one know in practical applications if an overcurrent protective de ...
... Molded case circuit breakers typically have lower single-pole interrupting capabilities than their multi-pole interrupting rating. See discussion for section 240.85 on slash ratings and single pole interrupting capabilities. How does one know in practical applications if an overcurrent protective de ...
FDC10 10 Series of Power Moudules : DC/DC Converter
... • UL 60950-1 and CB pending Option • Negative remote ON/OFF ...
... • UL 60950-1 and CB pending Option • Negative remote ON/OFF ...
al802ulada
... 1.Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two upper screws; level and secure. ...
... 1.Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two upper screws; level and secure. ...
0.9 Mb PDF - David Kleinfeld
... This must intercept IDS = IDSS in the active region. Here, we slide along the (flat) line of ID = IDSS so long as VDS > - VGS(off). To find the maximum load resistance that keeps us in the active zone, we first rewrite the load line as an expression for VDS, i.e., VDS = VDD - IDSS RLoad Noting that ...
... This must intercept IDS = IDSS in the active region. Here, we slide along the (flat) line of ID = IDSS so long as VDS > - VGS(off). To find the maximum load resistance that keeps us in the active zone, we first rewrite the load line as an expression for VDS, i.e., VDS = VDD - IDSS RLoad Noting that ...
Hardware Design Guidelines for Dual Role Port
... The USB Power Delivery (PD) Specification Revision 2.0, Version 1.1 defines power delivery up to 100 W (20 V at 5 A) over existing USB standards. The USB Type-C Cable and Connector Specification Revision 1.1 details a new reversible and sub-3-mm slim connector design that supports 100 W of power alo ...
... The USB Power Delivery (PD) Specification Revision 2.0, Version 1.1 defines power delivery up to 100 W (20 V at 5 A) over existing USB standards. The USB Type-C Cable and Connector Specification Revision 1.1 details a new reversible and sub-3-mm slim connector design that supports 100 W of power alo ...
short-circuit withstand current rating for low voltage
... for low voltage switchgears. The company is missing clear guidelines for “short-circuit current rating” (SCCR) or also referred to as “short-circuit current withstand rating”. Having such guidelines would enable E Avenue Oy to design their switchgear in a more cost efficient way within the standard ...
... for low voltage switchgears. The company is missing clear guidelines for “short-circuit current rating” (SCCR) or also referred to as “short-circuit current withstand rating”. Having such guidelines would enable E Avenue Oy to design their switchgear in a more cost efficient way within the standard ...
Catalogue 2014-15 Inside
... Consider us a “ONE STOP SHOP” for all your needs for measuring electrical and electronic parameters, from simple Voltmeters & Ammeters to Oscilloscopes and Spectrum Analyzers to High Voltage Testing equipment. Backed by years of accumulated experience, quality and acumen, the METRAVI brand is an all ...
... Consider us a “ONE STOP SHOP” for all your needs for measuring electrical and electronic parameters, from simple Voltmeters & Ammeters to Oscilloscopes and Spectrum Analyzers to High Voltage Testing equipment. Backed by years of accumulated experience, quality and acumen, the METRAVI brand is an all ...
MAX6400–MAX6405 µP Supervisory Circuits in 4-Bump (2 2) Chip-Scale Package
... Active-High Reset Output. RESET remains high while VCC is below the reset threshold and for at least 100ms after VCC rises above the reset threshold. ...
... Active-High Reset Output. RESET remains high while VCC is below the reset threshold and for at least 100ms after VCC rises above the reset threshold. ...
Large Dynamic Range Dynamically Biased Log-Domain
... the filter over a wide range of input currents are presented. With suitable dynamic biasing, the fabricated filter can maintain a THD < 40 dB and S/N > 53.7 dB for differential input current amplitudes ranging from 3 µA to 2.5 mA (a range of 58.4 dB). In terms of the range of signals that can be han ...
... the filter over a wide range of input currents are presented. With suitable dynamic biasing, the fabricated filter can maintain a THD < 40 dB and S/N > 53.7 dB for differential input current amplitudes ranging from 3 µA to 2.5 mA (a range of 58.4 dB). In terms of the range of signals that can be han ...
Rectifier
A rectifier is an electrical device that converts alternating current (AC), which periodically reverses direction, to direct current (DC), which flows in only one direction. The process is known as rectification. Physically, rectifiers take a number of forms, including vacuum tube diodes, mercury-arc valves, copper and selenium oxide rectifiers, semiconductor diodes, silicon-controlled rectifiers and other silicon-based semiconductor switches. Historically, even synchronous electromechanical switches and motors have been used. Early radio receivers, called crystal radios, used a ""cat's whisker"" of fine wire pressing on a crystal of galena (lead sulfide) to serve as a point-contact rectifier or ""crystal detector"".Rectifiers have many uses, but are often found serving as components of DC power supplies and high-voltage direct current power transmission systems. Rectification may serve in roles other than to generate direct current for use as a source of power. As noted, detectors of radio signals serve as rectifiers. In gas heating systems flame rectification is used to detect presence of a flame.Because of the alternating nature of the input AC sine wave, the process of rectification alone produces a DC current that, though unidirectional, consists of pulses of current. Many applications of rectifiers, such as power supplies for radio, television and computer equipment, require a steady constant DC current (as would be produced by a battery). In these applications the output of the rectifier is smoothed by an electronic filter (usually a capacitor) to produce a steady current.More complex circuitry that performs the opposite function, converting DC to AC, is called an inverter.