![SDL PowerPoint](http://s1.studyres.com/store/data/003179587_1-2068b70475b8fe1d797bbfefa77c3d1d-300x300.png)
SDL PowerPoint
... Use SPA Test Suite (SPATS) to validate SPA core components against Standards documents. SPATS will test each component in isolation (the Unit-Under-Test or UUT), simulating the non-UUT components in a protocol exchange Verifies protocols and message formats are followed Hardware support required for ...
... Use SPA Test Suite (SPATS) to validate SPA core components against Standards documents. SPATS will test each component in isolation (the Unit-Under-Test or UUT), simulating the non-UUT components in a protocol exchange Verifies protocols and message formats are followed Hardware support required for ...
daaac 4.0 - Voss Scientific
... • Once a system is set up, its configuration can be saved with a user supplied name • Convenient for saving standard test setups • Records system setup independently of data • May be restored at will in standalone mode • May be edited and deleted ...
... • Once a system is set up, its configuration can be saved with a user supplied name • Convenient for saving standard test setups • Records system setup independently of data • May be restored at will in standalone mode • May be edited and deleted ...
Raising BACnet® to the Next Level
... in the last decade of BACnet development in which several data link technologies were included — including Ethernet. But Ethernet is not IP, although it works well with IP networks. The BACnet community recognized the need for a convenient method of attaching to IP networks in a meaningful way with ...
... in the last decade of BACnet development in which several data link technologies were included — including Ethernet. But Ethernet is not IP, although it works well with IP networks. The BACnet community recognized the need for a convenient method of attaching to IP networks in a meaningful way with ...
GCF Generic Connector Framework Training Session
... Load agenda with additional topics of interest to your institution GCF Technical Architectural Overview Goal: Familiarize all participants with the GCF architecture and design methodology Conceptual Architecture Internal Components GCF Design standards GCF Protocol Definition of Terms ...
... Load agenda with additional topics of interest to your institution GCF Technical Architectural Overview Goal: Familiarize all participants with the GCF architecture and design methodology Conceptual Architecture Internal Components GCF Design standards GCF Protocol Definition of Terms ...
chapter3
... UDP: more • often used for streaming multimedia Length, in apps bytes of UDP – loss tolerant segment, including – rate sensitive • reliable transfer over UDP: add reliability at application layer – application-specific error recovery! ...
... UDP: more • often used for streaming multimedia Length, in apps bytes of UDP – loss tolerant segment, including – rate sensitive • reliable transfer over UDP: add reliability at application layer – application-specific error recovery! ...
Switched Broadcast 2003
... If you can remotely access serial consoles – No need to run to the server rooms – Your response to outages/problems is faster – You can easily check machines in other buildings, even in other cities – Reduced downtime saves the company money! ...
... If you can remotely access serial consoles – No need to run to the server rooms – Your response to outages/problems is faster – You can easily check machines in other buildings, even in other cities – Reduced downtime saves the company money! ...
Product Overview (PDF)
... Double the functionality. The 3086 complete suite of multiplexing/routing protocols, allows for simultaneous transport of packetized data to the Ethernet port, and serial synchronous data on its X.21/V.35/E1 port over a single DSL link ...
... Double the functionality. The 3086 complete suite of multiplexing/routing protocols, allows for simultaneous transport of packetized data to the Ethernet port, and serial synchronous data on its X.21/V.35/E1 port over a single DSL link ...
USB Extender Plus Series
... (600 meters) through a Gigabit Ethernet network Extends USB peripherals over one CATx cable point-to-point up to 330 feet (100 meters) Supports USB 2.0/1.0 devices with data rates up to 480 Mbps. Compatible with USB 3.0 devices that can operate at USB 2.0 data rates ...
... (600 meters) through a Gigabit Ethernet network Extends USB peripherals over one CATx cable point-to-point up to 330 feet (100 meters) Supports USB 2.0/1.0 devices with data rates up to 480 Mbps. Compatible with USB 3.0 devices that can operate at USB 2.0 data rates ...
Data Communication and Network Standards
... A Protocol is one of the components of a data communications system. Without protocol communication cannot occur. The sending device cannot just send the data and expect the receiving device to receive and further interpret it correctly. When the sender sends a message it may consist of text, number ...
... A Protocol is one of the components of a data communications system. Without protocol communication cannot occur. The sending device cannot just send the data and expect the receiving device to receive and further interpret it correctly. When the sender sends a message it may consist of text, number ...
AS/CA S003.1:2010 - Communications Alliance
... This introduction for the AS/CA S003.1 Australian Standard – Requirements for Customer Access Equipment for connection to a Telecommunications Network — Part 1: General Standard is not an authoritative section of this Standard and is only provided as guidance for the user of the Standard to outline ...
... This introduction for the AS/CA S003.1 Australian Standard – Requirements for Customer Access Equipment for connection to a Telecommunications Network — Part 1: General Standard is not an authoritative section of this Standard and is only provided as guidance for the user of the Standard to outline ...
ppt
... end-end control (no network assistance) transmission rate limited by congestion window ...
... end-end control (no network assistance) transmission rate limited by congestion window ...
ABLELink - automa.it
... UDP Mode:UDP is a fast but non-guaranteed datagram delivery protocol. GW51C-MAXI Serial Server can be configured in a UDP mode on a TCP/IP Network to establish a connection, using unicast or broadcast data to and from a serial device to one or multiple host computers (UDP Mode) ...
... UDP Mode:UDP is a fast but non-guaranteed datagram delivery protocol. GW51C-MAXI Serial Server can be configured in a UDP mode on a TCP/IP Network to establish a connection, using unicast or broadcast data to and from a serial device to one or multiple host computers (UDP Mode) ...
Pocket Guide - Industrial Networking Solutions
... Alternatively, Hirschmann and Siemens offer the HIPER-Ring *, a solution which is also based on a ring structure and is specially designed for the requirements of industrial applications. While it normally takes more than 30 seconds to compensate for a line failure with STP and one second with RSTP, ...
... Alternatively, Hirschmann and Siemens offer the HIPER-Ring *, a solution which is also based on a ring structure and is specially designed for the requirements of industrial applications. While it normally takes more than 30 seconds to compensate for a line failure with STP and one second with RSTP, ...
CCNA 2 Module 9 Exam visual content
... connected to Switch 1 by straight through network cable. Switch 1 is also connected by straight through cable to Router A’s Fast Ethernet port or Fa0/0. Router A has it’s Serial Inteface S0/0 configured with an IP address of 192.168.2.1/24. The serial link from Router A to Router B is established by ...
... connected to Switch 1 by straight through network cable. Switch 1 is also connected by straight through cable to Router A’s Fast Ethernet port or Fa0/0. Router A has it’s Serial Inteface S0/0 configured with an IP address of 192.168.2.1/24. The serial link from Router A to Router B is established by ...
Lecture 6
... underlying channel may flip bits in packet checksum to detect bit errors the question: how to recover from errors: acknowledgements (ACKs): receiver explicitly tells sender ...
... underlying channel may flip bits in packet checksum to detect bit errors the question: how to recover from errors: acknowledgements (ACKs): receiver explicitly tells sender ...
this section - PDF
... 10/100 ports and modern QoS, Tagged VLAN, and full SNMP management in a cost-effective package. The two Dual Media Gigabit Ethernet ports use onboard RJ-45 connectors to permit easy clustering of switches, and auto-detected SFP modules for fiber optic switch interconnection at longer distances. Both ...
... 10/100 ports and modern QoS, Tagged VLAN, and full SNMP management in a cost-effective package. The two Dual Media Gigabit Ethernet ports use onboard RJ-45 connectors to permit easy clustering of switches, and auto-detected SFP modules for fiber optic switch interconnection at longer distances. Both ...
GenericFaultyCable
... indicates that they are from Compaq. Check with HP/Compaq to see if perhaps your adapters can be teamed together for load balancing and fault tolerance. It may also be a wise to check for current version of SoftPaq’s and ROMPaq’s for your Proliant series servers as well. ...
... indicates that they are from Compaq. Check with HP/Compaq to see if perhaps your adapters can be teamed together for load balancing and fault tolerance. It may also be a wise to check for current version of SoftPaq’s and ROMPaq’s for your Proliant series servers as well. ...
1 - IC Intracom
... for even further networking expansion between extended nodes. Allows for the quick and easy addition of Coaxial segments to existing 10Base-T networks. ...
... for even further networking expansion between extended nodes. Allows for the quick and easy addition of Coaxial segments to existing 10Base-T networks. ...
Ethernet Data Link Layer Standards
... supplicant. Which device is the verifier? (This is a trick question, but it gets at an important point.) 5-4. In Figure 5-22, which server host(s) can Host C access? Design Questions 5-5. Design an Ethernet network to connect a single client PC to a single server. Both the client and the server will ...
... supplicant. Which device is the verifier? (This is a trick question, but it gets at an important point.) 5-4. In Figure 5-22, which server host(s) can Host C access? Design Questions 5-5. Design an Ethernet network to connect a single client PC to a single server. Both the client and the server will ...
ATM - La Salle University
... throughput levels. This is used for applications, such as file transfer, that can tolerate delays. • Available Bit Rate (ABR) guaranteed minimum capacity but allows data to be bursted at higher capacities when the network is free. CSIT 220 (Blum) ...
... throughput levels. This is used for applications, such as file transfer, that can tolerate delays. • Available Bit Rate (ABR) guaranteed minimum capacity but allows data to be bursted at higher capacities when the network is free. CSIT 220 (Blum) ...
PinPoint X CoverTitle Quick Start Guide for Verizon
... Caution: The PinPoint X is in a hardened case and designed for use in industrial and extreme environments. However, unless you are using cables expressly designed for such environments, they can fail if exposed to the same conditions the PinPoint X can withstand. ...
... Caution: The PinPoint X is in a hardened case and designed for use in industrial and extreme environments. However, unless you are using cables expressly designed for such environments, they can fail if exposed to the same conditions the PinPoint X can withstand. ...
Part 1 Module 9 Controller Area Network
... CAN covers some unique internal features you can’t find elsewhere.. there is an increasing number of CAN-applications also outside the automotive industry ...
... CAN covers some unique internal features you can’t find elsewhere.. there is an increasing number of CAN-applications also outside the automotive industry ...
Lecture 2: WPAN
... ZigBee technology is simpler (and less expensive) than Bluetooth. The main objectives of an LR-WPAN like ZigBee are ease of installation, reliable data transfer, short-range operation, extremely low cost, and a reasonable battery life, while maintaining a simple and flexible protocol. The raw data r ...
... ZigBee technology is simpler (and less expensive) than Bluetooth. The main objectives of an LR-WPAN like ZigBee are ease of installation, reliable data transfer, short-range operation, extremely low cost, and a reasonable battery life, while maintaining a simple and flexible protocol. The raw data r ...
Transport Overview - Zoo | Yale University
... Admin and recap Overview of transport layer UDP Reliable data transfer, the stop-and-wait ...
... Admin and recap Overview of transport layer UDP Reliable data transfer, the stop-and-wait ...
RS-232
In telecommunications, RS-232 is a standard for serial communication transmission of data. It formally defines the signals connecting between a DTE (data terminal equipment) such as a computer terminal, and a DCE (data circuit-terminating equipment, originally defined as data communication equipment), such as a modem. The RS-232 standard is commonly used in computer serial ports. The standard defines the electrical characteristics and timing of signals, the meaning of signals, and the physical size and pinout of connectors. The current version of the standard is TIA-232-F Interface Between Data Terminal Equipment and Data Circuit-Terminating Equipment Employing Serial Binary Data Interchange, issued in 1997.An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. However, RS-232 is hampered by low transmission speed, large voltage swing, and large standard connectors. In modern personal computers, USB has displaced RS-232 from most of its peripheral interface roles. Many computers do not come equipped with RS-232 ports and must use either an external USB-to-RS-232 converter or an internal expansion card with one or more serial ports to connect to RS-232 peripherals. Nevertheless, RS-232 devices are still used, especially in industrial machines, networking equipment and scientific instruments.