TRF37T05 300-MHz to 4-GHz Quadrature Modulator (Rev. A)
... 0.25-V common-mode voltage for optimum linearity performance. The TRF37T05 also provides a fast power-down pin that can be used to reduce power dissipation while maintaining optimized adjusted carrier feed-through performance in TDD applications. ...
... 0.25-V common-mode voltage for optimum linearity performance. The TRF37T05 also provides a fast power-down pin that can be used to reduce power dissipation while maintaining optimized adjusted carrier feed-through performance in TDD applications. ...
Detection and Analysis of Partial Discharges in Non
... (PZT), small PD signals can be converted to pressure signal and then converted to an optical wavelength signal with FBG. The optical signal is isolated from the electric field; therefore its attenuation and anti-jamming performance will be better than traditional methods. Two sensors, one with reson ...
... (PZT), small PD signals can be converted to pressure signal and then converted to an optical wavelength signal with FBG. The optical signal is isolated from the electric field; therefore its attenuation and anti-jamming performance will be better than traditional methods. Two sensors, one with reson ...
Radiometer systems
... (e.g., amplifier, filter, attenuator, cable). Input to this device is a signal, Psi, and noise, Pni. Output from this device is a signal, Pso, and noise, Pno. The signal-to-noise ratio, SNR, can be determined at the input as well as the output. ...
... (e.g., amplifier, filter, attenuator, cable). Input to this device is a signal, Psi, and noise, Pni. Output from this device is a signal, Pso, and noise, Pno. The signal-to-noise ratio, SNR, can be determined at the input as well as the output. ...
AN4075
... There is a trade-off between current consumption and resolution. The MMA8451, 2, 3 accelerometers have been designed to fit as many applications and markets as possible. The MMA845xQ series of accelerometers have been designed such that the same accelerometer can be used for high resolution applicat ...
... There is a trade-off between current consumption and resolution. The MMA8451, 2, 3 accelerometers have been designed to fit as many applications and markets as possible. The MMA845xQ series of accelerometers have been designed such that the same accelerometer can be used for high resolution applicat ...
NI SCB-68A User Manual and Specifications
... The SCB-68A is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. Thi ...
... The SCB-68A is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. Thi ...
Standard for Single Diamond Overlap Phasing
... This Specification has been prepared by the Roads and Traffic Authority of New South Wales (referred to herein as RTA) for use, insofar as it is applicable, in the State of New South Wales for equipment supplied under an RTA procurement order or contract, or under a procurement order or contract fro ...
... This Specification has been prepared by the Roads and Traffic Authority of New South Wales (referred to herein as RTA) for use, insofar as it is applicable, in the State of New South Wales for equipment supplied under an RTA procurement order or contract, or under a procurement order or contract fro ...
ISMT multimedia
... Sampling frequency must be at least twice the highest frequency in the signal spectrum (Nyquist); for audio it is about 40 kHz CD quality recording – 44,100 Hz (44,025 is sometimes used for TV compatibility) lower sampling frequencies may be used … with corresponding loss of quality ...
... Sampling frequency must be at least twice the highest frequency in the signal spectrum (Nyquist); for audio it is about 40 kHz CD quality recording – 44,100 Hz (44,025 is sometimes used for TV compatibility) lower sampling frequencies may be used … with corresponding loss of quality ...
LR12000E/LR8100E/LR4100E/LR4200E Laboratory Recorders
... Prints all setup information (ranges, alarms, etc.) on chart. Prints time and measured values of all channels on one line when MANUAL PRINT key is pressed. Prints user-defined messages up to 70 characters long, with time. Printed when MANUAL MESSAGE key is pressed. Provided with REMOTE option; print ...
... Prints all setup information (ranges, alarms, etc.) on chart. Prints time and measured values of all channels on one line when MANUAL PRINT key is pressed. Prints user-defined messages up to 70 characters long, with time. Printed when MANUAL MESSAGE key is pressed. Provided with REMOTE option; print ...
Design Techniques for EMC, 2006 series
... Designing-in EMC always looks as if it is going to increase the cost of the bill of materials (the ‘BOM cost’) – but by the time a design is EMC compliant and ready for market it has usually decreased the BOM cost. Even where the final BOM cost is higher, the true cost of manufacture and the profita ...
... Designing-in EMC always looks as if it is going to increase the cost of the bill of materials (the ‘BOM cost’) – but by the time a design is EMC compliant and ready for market it has usually decreased the BOM cost. Even where the final BOM cost is higher, the true cost of manufacture and the profita ...