Download ME35/19x50-P1-24A1R2

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Audio power wikipedia , lookup

TRIAC wikipedia , lookup

Flip-flop (electronics) wikipedia , lookup

Ohm's law wikipedia , lookup

Analog-to-digital converter wikipedia , lookup

Multimeter wikipedia , lookup

Radio transmitter design wikipedia , lookup

Surge protector wikipedia , lookup

Power MOSFET wikipedia , lookup

Amplifier wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Integrating ADC wikipedia , lookup

CMOS wikipedia , lookup

Valve RF amplifier wikipedia , lookup

Negative-feedback amplifier wikipedia , lookup

Voltage regulator wikipedia , lookup

Valve audio amplifier technical specification wikipedia , lookup

Transistor–transistor logic wikipedia , lookup

Wilson current mirror wikipedia , lookup

Schmitt trigger wikipedia , lookup

Power electronics wikipedia , lookup

Operational amplifier wikipedia , lookup

Current mirror wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Rectiverter wikipedia , lookup

Opto-isolator wikipedia , lookup

Transcript
234820851
Page 1 / 1
Fact Sheet
ME35/19x50-P1-24A1R2-M239 #2
Wandfluh art no 260.5066
Special Type Mobile Coil DSV Controller

with voltage feedback (according type code ME35/19x50-P1-24A1R2…)
M239 denominates


Special solenoid output A+ and B+ working as an H-bridge driver
to drive the solenoid current both in positive and negative direction
Explanations
MAIN (Device receptacle, M23, 12-pin, male)
 Supply+ is the +24V supply input to power the DSV and requires 0 VDC as zero volt reference
 An.in1+ and An.in1- is the differential voltage command input
 An.in2+ and An.in2- is the differential current command input
 Stab.out is the DSV +10V output to power a command potentiometer or joystick
 per type code ME35/19x50-P1-24A1R2… analog input 1 is pre-parameterized as 0..+10V command value
(this setting can be changed in PASO to +/-10V, or to input 2 with 0/4..20mA)
 Hint: the zero volt references of the DSV and of the external command value source
should not differ more than 2 Volts; therefore the used An.in.x– may have to be connected to 0 VDC
SENSOR (Device receptacle, 5-pin, female)
 Sens.Sup+ is the DSV +24 supply output to power the external sensor
 Sens.Sig+ is the DSV feedback input to read in the sensor value (voltage according DSV341D212…)
 Stab.out is the DSV +10V output to alternatively power the external sensor
Parameterization Hint
 The solenoid current cannot be measured with this “H-bridge” output.
 Therefore the PASO setting “proportional solenoid without current measurement” applies.
 Default solenoid output setting is 10%...75% PWM duty cycle
where as 10% correspond to minimum current I-min, and 75% correspond to the nominal current
Hint: settings higher than 75% PWM duty cycle may overheat the solenoid
Lasered pin assignment
Links
http://www.wandfluh.com/en/downloads.html
 Menu “Documentation” for datasheets (Register 1.13 for Electronics)
 Menu “Software” for Parameterization Software PASO
 Menu “Accompanying documents for Electronics” for detailed operating guides
Wandfluh AG
10.04.2013
A.Feuz, TEL