TYPE:
CATALOG #:
NOTES:
IL Series
6, 12 & 24Volt
Heavy Duty Industrial Emergency Unit
Unit Rating Chart
Standard Features
• Each unit comes with two (2) impact resistant, flame retardant
thermoplastic EF-18 lamp heads with 9 watt high intensity
incandescent lamps (standard).
• All steel construction. Gray baked enamel finish.
• Available with sealed, maintenance-free Nickel-Cadmium, Long
Life Lead, Lead-Calcium (Free Electrolyte) or Lead-Calcium
batteries.
• PulsePlus Charger circuitry offers 120/277 volt input 60 Hz,
0.3/0.15A (other inputs available), fused output circuit(s), dual
diagnostic indicator lights, temperature compensation, sealed
relay, low voltage battery disconnect, brownout protection and
lockout (automatic battery connect).
• Provision for mounting to any standard 4” octagonal electrical
box. The hinged and lockable front door allows easy access for
maintenance and provides security against unauthorized access
and vandalism.
• UL Listed. Complies with NEC, Life Safety Code and OSHA.
Approved for use in the Commonwealth of Pennsylvania.
• 3-year full warranty, excluding lamps and fuses
Furnished standard with two 9 watt High Intensity Incandescent lamps.
Unit Equipment – NO REMOTE capability
Sealed
D.C.
Maintenance-Free
Voltage
Battery Types
Nickel-Cadmium
Long Life Lead
Lead-Calcium
Nickel-Cadmium
Long Life Lead
Dimensions are approximate and subject to change.
Lead-Calcium
(Immobilized
Electrolyte)
Lead-Calcium
Unit Warranty*
Entire unit (excluding lamps and fuses) carries a 3-year
Full Warranty.
ILSC18-2
ILSE18-2
ILSM18-2
Watts to 87 1⁄2% of rated battery # of
voltage*
Load
Fuses
1⁄2
1 hrs. 2 hrs. 4 hrs. 8 hrs.
18
12
6
18
11
6
18
12
7
-
Unit Equipment – WITH REMOTE capability
Outline and Dimensions
Knockouts for 1⁄2” Conduit:
-2 each side, 1 rear (7⁄8”
Dia) KO.
6
6
6
Model
Number
6
12
12
24
24
6
6
6
6
6
12
12
12
12
24
24
6
ILSC25-2
12ILSC36-2
12ILSC50-2
24ILSC72-2
24ILSC100-2
ILSE27-2
ILSE36-2
ILSE54-2
ILSE80-2
ILSE110-2
12ILSE36-2
12ILSE54-2
12ILSE72-2
12ILSE110-2
24ILSE72-2
24ILSE110-2
ILC87-2
25
36
50
72
100
27
36
54
80
110
36
54
72
110
72
110
87
18
21
36
42
73
16
24
36
65
72
24
37
48
74
48
74
70
9
12
18
24
36
10
13
20
35
40
13
21
26
43
26
43
41
6
10
12
20
6
7
11
19
24
7
10
14
21
14
21
24
1
1
2
2
1
1
2
2
2
2
-
6
ILC100-2
100
77
47
24
-
6
6
6
6
6
12
12
12
24
ILSM27-2
ILSM36-2
ILSM54-2
ILSM81-2
ILSM110-2
12ILSM36-2
12ILSM54-2
12ILSM110-2
24ILSM110-2
27
36
54
81
110
36
54
110
110
18
25
37
54
72
25
37
72
72
10
14
21
36
40
14
21
40
40
6
7
12
18
24
7
12
24
24
1
1
2
2
*National Electrical Code Specification
Battery Warranty*
Unit batteries are warranted as follows:
Sealed Nickel-Cadmium: ILSC – 10-year life expectancy,
5-year Full Warranty, plus 5-year pro rata warranty.
Sealed Long Life Lead: ILSE – 12-year life expectancy,
5-year Full Warranty, plus 5-year pro rata warranty.
Sealed Lead Calcium (immobilized electrolyte): ILC – 12-year
life expectancy, 5-year Full Warranty, plus 5-year pro rata warranty.
Sealed Lead Calcium: ILSM – 8-year life expectancy,
3-year Full Warranty, plus 3-year pro rata warranty.
*Subject to proper installation and maintenance.
All information and specifications contained in this specsheet are subject to change due to engineer design, errors and omissions. Illustrations and diagrams within this specsheet may vary from actual products.
2013© Thomas & Betts Limited. All rights reserved.
Suggested Specification
Supply and install EMERGI-LITE® Series ILSC_________,
ILSE_________, ILSM_________ , ILC_________ in 6
volt, single or double heads, with electrically compatible remote
fixtures or exit signs as indicated on the plans. The emergency
lighting unit shall be a self-contained fixture including sealed,
maintenance-free battery. TYPE ILSC to be supplied with long
life Nickel-Cadmium battery. TYPE ILSE to be supplied with
long life pure lead battery. TYPE ILSM to be supplied with lead
calcium battery. TYPE ILC to be supplied with lead calcium (free
electrolyte) battery. The unit shall supply the rated load for a
minimum of 90 minutes or to 871/2% of rated battery voltage.
The unit shall be rated 120/277 Vac, 60 Hz and be UL924 Listed.
The unit charger shall utilize an integrated circuit which samples
the battery in relation to its temperature, state of charge and
input voltage fluctuations. The charger shall be current limited,
temperature compensated, short-circuit protected and reverse
polarity protected. The unit shall be furnished with an electronic
lockout circuit which will connect the battery when the AC circuit
is activated, and an electronic brownout circuit which will activate
Accessories (order as a seperate item)
Description
Add Suffix
B2
MP3-GY
WG3-E
Mounting bracket
Mounting shelves (gray)
Wire Guard
the unit when utility power dips below 80-85% of nominal voltage.
A low voltage battery disconnect circuit shall be provided and
will disconnect the load and circuitry from the battery when it
reaches 871/2% of its nominal voltage. The unit shall be capable
of full recharge in compliance with UL924 specifications. The unit
shall be furnished with sealed dust-tight relay, a test switch and
dual diagnostic LED indicator lights (hi-charge and AC pilot). The
entire cabinet shall be constructed of 20 gauge steel in ASA61
grey baked enamel finish. The door shall be hinged to provide
full access to the battery and charger for ease of installation and
servicing. The door shall be lockable to prohibit unauthorized entry
or vandalism. Unit shall have rear keyhole mounting slots and
will be designed to mount directly to any standard 4” octagonal
electrical box. Unit shall have provisions for mounting up to
three lighting heads on the cabinet. Unit shall be furnished with
two EF18 lighting heads constructed of impact resistant, flame
retardant thermoplastic material complete with 9W High Intensity
Incandescent lamps. Fused output terminals shall be provided for
ease of remote lamp connections. Every IL Series unit shall be
fully warranted for three years, subject to proper installation and
maintenance.
Unit shall be EMERGI-LITE® catalog number____________.
How to Order
Series/Voltage
ILC= 6V
ILS= 6V industrial
12ILS= 12V
24ILS= 24V
Unit Capacity
# of Heads
87= 87W lead calcium
100= 100W lead calcium
C18= 18W Ni-Cd
C25= 25W Ni-Cd
E18= 18W long life lead
E27= 27W long life lead
E36= 36W long life lead
E50= 50W long life lead
E80= 80W long life lead
E110= 110W long life lead
M18= 18W lead calcium
M27= 27W lead calcium
M36= 36W lead calcium
M54= 54W lead calcium
M81= 81W lead calcium
M110= 110W lead calcium
C36= 36W Ni-Cd
C50= 50W Ni-Cd
E36= 36W long life lead
E54= 54W long life lead
E80= 80W long life lead
E110= 110W long life lead
M36= 36W lead calcium
M54= 54W lead calcium
M110= 110W lead calcium
C100= 100W Ni-Cd
E72= 72W long life lead
E110= 110W long life lead
M110= 110W lead calcium
C72= 72W Ni-Cd
-0= No head
-1= One head
-2= Two heads
-3= Three heads
Lamp Type
Blank=6V-9W, 12V-9W, 24V-9W inc.
wedge base
H_= Halogen bi-pin
Z_= Tungsten incandescent
U_= Tungsten sealed beam
X_= Halogen sealed beam
NOTE: For the complete lamp suffix please
refer to the lamp data sheet on page 112
Options
-A= Ammeter
-V= Voltmeter
-AD= Auto-diagnostic audible*
-ADNA= Auto-diagnostic non-audible*
-CP= Cord and plug 120V only
-D1= Time delay 5 min
-D2= Time delay 10 min
-D3= Time delay 15 min**
XP= Flexible cord provided with 120 or 277 VAC
plug***
-K= Lamp disconnect switch
-OW= Off-white cabinet and heads
NEX= Nexus® wired
NEXRF= Nexus® wireless
*Not available on 24V-100W Ni-Cd units
**Not required with AD or ADNA - time delay standard
at 15 minutes
***Standard cord is 3 ft. (custom lengths available)
EXAMPLE: ILC87-0-A
All information and specifications contained in this specsheet are subject to change due to engineer design, errors and omissions. Illustrations and diagrams within this specsheet may vary from actual products.
2013© Thomas & Betts Limited. All rights reserved.