Survey
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Protection Relays & Controls Generator & Single-Function Protection–Overcurrent/Short-Circuit T2500 Series Overcurrent and Short-Circuit Relay Description The combined T2500 3-Phase Overcurrent and Short-Circuit Relay is used for protection of generators and power transmissions. The short-circuit relay protects against faults causing high currents, and the overcurrent relay protects against thermal damage. Features & Benefits Features Accepts high supply voltage variation Simplified Circuit Diagram 1 2 SUPPLY 3 U T2500 (Overcurrent & Short-Circuit Relay) 11 I1 I2 I3 SHORT CIRCUIT 12 13 14 15 OVERCURRENT 16 19 L1 L2 L3 17 18 10 9 8 7 6 5 4 20 Connection between 20 and 19 gives instant operation of Relay 2. Connection between 20 and 17 gives delayed operation of Relay 2. Connection between 20 and 18 gives synchronized operation of Relay 1 and Relay 2. Disconnecting the diode between 17 and 18 will disable operation of Relay 1 from overcurrent. Latching output relays can be reset or disabled by bridging terminals 5 and 6. Ordering Information Terminals Ordering Number 1-3 2-3 T2500.0010 T2500.0020 T2500.0030 T2500.0040 T2500.0050 T2500.0060 T2500.0070 450 V 230 V 480 V 450 V 24 Vdc 230 V 450 V 400 V 5 A 5A 415 V 5 A 400 V 1 A 5A 5A 400 V 5 A T2500.0080 450 V 400 V 5 A T2500.0090 T2500.0100 480 V 415 V 5 A 24 Vdc 1A T2500.0110 450 V T2500.0120 24 Vdc IN 400 V 5 A 5A function Latching output, resetable Latching output, resetable Latching output, resetable Latching output, resetable Latching output, resetable De-energized extra output relay De-energized extra output relay De-energized extra output relay, latching outputs De-energized extra output relay De-energized extra output relay De-energized extra output relay, latching short circuit output De-energized extra output relay, de-energized relay 1, no internal power backup Visual indication of power, pick-up, and output trip Direct line-line or lineneutral voltage supply (up to 690 Vac) Combining 2 protection functions in same enclosure Available with extra output Versions available with separate 24 Vdc supply Galvanic isolated inputs DIN-rail or screw-mount & adjustment by potentiometers BENEFITS Ensures correct operation in spite of voltage supply fluctuations (fulfills marine class requirement) Provides quick and concise status information Simplifies design and installation. No need for PTs. Economic solution, occupying less space in the switch panel Economic solution for non-essential load tripping Safe operation–Maintains protection regardless of system voltage failure Protects the unit against high AC voltage and currents from the installation including spikes Easy installation Specifications Overcurrent Trip Level 0.5-1.4 x IN Delay 3-30 sec. Short-Circuit Trip Level 1.0-4.0 x IN Delay 0.1-1.0 sec. Max. Voltage 660 V Voltage Range 60-110% Consumption 5 VA at UN Continuous Current 2 x IN Frequency Range 45-400 Hz Output Relay Normally energized Extra Output Relay Normally de-energized Contact Rating AC: 400 V, 5 A, 2000 VA; DC: 150 V, 5 A, 150 W Overall Accuracy ±5% Repeatability ±1% Operating Temperature –20°C to + 70°C EMC CE according to EN50081-1, EN50082-1, EN50081-2, EN50082-2 Approvals Certified by major marine classification societies Burn-in 50 hours before final test Enclosure Material Polycarbonate. Flame retardant Weight 0.5 kg DimensionsH 70 mm (2.76”); W 100 mm (3.94”); D 115 mm (4.52”) Installation 35 mm DIN rail or 4 mm (3/16”) screws Other combinations and voltages are available on request. www.BDTIC.com/littelfuse © 2013 Littelfuse Protection Relays & Controls Littelfuse.com/t2500 Rev: 4-A-050213