Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Identifying SLC 500™ System Components SLC 500 System Options The SLC 500 line of processors comprises both fixed and modular processor styles.: Fixed Hardware Fixed SLC 500 processors have a built-in power supply with I/O modules in one unit. The following options are available with the fixed-hardware processor: 20, 30, or 40 digital I/O points Two-slot expansion chassis The following graphic shows a fixed SLC 500 processor with 20 I/O points and a two-slot expansion chassis SLC 500 System Modular Hardware The following options are available with the modular-hardware processor: Seven power supply types Up to 4096 inputs and 4096 outputs Five processor types The following graphic shows a modular SLC 5/04 ™ processor: SLC 500 System Modular SLC 500 System Components The modular SLC 500 system components include a power supply, processor, chassis, and I/O modules. Power Supply Power Supply: A component that provides system power requirements for the processor and I/O modules. Seven power supplies, three AC-input power supplies and four DC-input power supplies, are available: Power supply Power Supply Nominal Input Voltage 1746-P1 120V or 220V AC 1746-P2 120V or 220V AC 1746-P3 24V DC 1746-P4 120V or 220V DC 1746-P5 125V DC 1746-P6 48V DC 1746-P7 12V DC 24V DC Backplane Output Current 2A at 5V DC 5A at 5V DC 3.6A at 5V DC 10A at 5V DC 5A at 5V DC 5A at 5V DC 2A at 5V DC 3.6A at 5V DC Power supply All power supplies have a lightemitting diode (LED) that indicates proper power supply. Power supplies are designed to withstand brief power losses (between 20 ms and 3 s) without affecting the operation of the system. Processor Processor: A component that acts as the brain of the system, receiving information from input devices via the I/O system, making decisions based on that information, and then sending information to the output devices via the I/O system. SLC 500 processors offer a wide range of choices in memory, I/O capacity, instruction set, and communications ports. The following table lists characteristics of the modular processors: SLC 500 Processor TYPE SLC 5/01 SLC 5/01 SLC 5/02 SLC 5/03 SLC 5/03 SLC 5/03 SLC 5/04 SLC 5/04 SLC 5/04 SLC 5/05 SLC 5/05 SLC 5/05 PART # 1747 L511 L514 L524 L531 L532 L533 L541 L542 L543 L551 L552 L553 MEMORY 1K 4K 4K 8K 16 K 32 K 16 K 32 K 64 K 16 K 32 K 64 K CURRENT/5 VDC 90 mA 90 mA 90 mA 500 mA 500 mA 500 mA 1000 mA 1000 mA 1000 mA 1000 mA 1000 mA 1000 mA 0 mA 0 mA 175 mA 175 mA 175 mA 200 mA 200 mA 200 mA 200 mA 200 mA 200 mA CURRENT/ 24 VDC 0 mA DISCRETE I/O max 7880 8192 8192 CHASSIS/Slots 3/30 3/30 3/30 DH-485 DH-485 COMM. On board DH-485 SLAVE SLAVE MEMORY MODULE EEPROM EEPROM EEPROM PROG. LANG. RS LOGIX 500 PROG. INST. SCAN TIME 52 52 71 8192 8192 8192 8192 8192 8192 8192 8192 8192 3/30 3/30 3/30 3/30 3/30 3/30 3/30 3/30 3/30 DH-485 & DH-485 & DH-485 & DH+ & DH+ & DH+ & ETHERNET & RS-232 RS-232 RS-232 RS-232 RS-232 RS-232 RS-232 FLASH EEPROM 107 107 107 107 107 107 107 107 107 8 ms/K 8 ms/K 4.8 ms/K 1 ms/K 1 ms/K 1 ms/K 0.9 ms/K 0.9 ms/K 0.9 ms/K 0.9 ms/K 0.9 ms/K 0.9 ms/K Processor The following features are specific for each processor type: Memory capacity Complexity of available instruction set Communications options Time required to execute the control program Chassis Chassis: A hardware assembly that houses the processor and I/O modules. SLC modular chassis provide the following functions: Power distribution Containment of I/O modules Communication path between I/O modules and processor SLC modular chassis are available in four sizes: 4-slot 7-slot 10-slot 13-slot : A chassis requires a power supply (which connects to the chassis without a separate cable) to provide power to the processor and each I/O slot. Additionally, chassis can be connected together to increase the I/O available to a processor, as shown in the following graphic: I/O Modules I/O Modules: Electronic plug-in units used to interface with the input and output devices in the machine or process being controlled. Input modules receive data from input devices and send it to the processor. Output modules receive data from the processor and send it to output devices. I/O modules I/O Module Function Examples of devices that connect to module Digital/discrete Sends& receives on/off signals Pushbuttons, indicators, photo eyes, starters Analog Sends& receives variable input/output signals Temperature, voltage, speed current devices Process Provides process control Temperature, weighing devices Servo positioning Provides positioning control Hydraulic rams, encoders Specialized Provides specific functions Flowmeters, clutch/brake systems EEPROM Memory Module: A module that can be inserted into a SLC 500 processor to maintain a copy of the project in case the processor experiences either of these situations: Memory corruption Extended power loss Memory module information can be found under the Mem Module tab of the processor status file, as shown in the following graphic: Communication The following terms are associated with network communications: Network: A series of stations (nodes) physically connected together. Node: A device on a network capable of sending or receiving information. Link: The path or physical means established for transmitting data between two or more locations. Baud rate: A unit of signaling speed, across a communications link, equal to the number of signal events per second (bits per second). Data Highway Plus (DH+) Network: A Data Highway Plus ™ (DH+) is a local area network designed to support remote programming for factory floor applications. A DH+ network has the following characteristics: Uses baud rates up to 230.4 kbit/s Allows a maximum of 64 (0-77 octal) nodes Allows a maximum network length of 3,048 m (10,000 ft) at 57.6 kbit/s Communications speed is influenced by distance within the DH+ network. Example: DH+ Network Channel 1 of an SLC 5/04 processor is used to connect to a DH+ network. An example of SLC 500™ processors on a DH+ network is shown in the following graphic: DH 485 Network: A DH 485 network is a local area network designed for plant floor applications. DH 485 connections enable you to go online to any processor on a DH 485 network from one connection point. A DH 485 network has the following characteristics: Uses baud rates up to 19,200 bit/s Allows a maximum of 32 (0-31 decimal) nodes Uses a maximum cable length of 1.2 km (4,000 ft Example: DH 485 Network Channel 1 of SLC 5/01, SLC 5/02, and SLC 5/03 processors is used to connect to the DH 485 Network. An example of SLC 500 ™ processors on a DH 485 network is shown in the following graphic RS-232 (Serial) Connection: An RS-232 serial port allows you to go online to a specific processor by connecting to the communications port of a computer: Uses baud rates up to 19,200 bit/s Requires physical connection to the processor to which you want to go online (cannot "see" other processors on the network) Telephone and radio modems can be integrated into the RS-232 interface, thereby allowing communications over long distances. Example: RS-232 Connection Channel 0 of SLC 5/03, SLC 5/04, and SLC 5/05 processors is used for an RS-232 connection. An example of an RS-232 connection is shown in the following graphic: Universal Remote I/O Network: A Universal Remote I/O network connects SLC 500 processors to remote I/O chassis and intelligent devices such as operator interfaces and AC and DC drives. The Universal Remote I/O network has the following characteristics: Uses baud rates up to 230.4 kbit/s Allows remote I/O scanners to connect to a maximum of 32 I/O chassis or other adapter-type devices on a single link Allows a maximum network length of 3,048 m (10,000 ft) at 57.6 kbit/s Example: Universal Remote I/O An example of an SLC 5/04 processor with a 1747-SN scanner module on a Universal Remote I/O network is shown in the following graphic: DeviceNet Network: A DeviceNet network connects low-level devices directly to plant-floor controllers over an open network. A DeviceNet network has the following characteristics: Uses baud rates up to 500 kbit/s Allows up to 64 nodes Has a maximum length of 487 m (1,600 ft) Example: DeviceNet Network An example of an SLC 500 processor with a 1747-SDN DeviceNet scanner module on a DeviceNet network is shown in the following graphic: ControlNet Network: A ControlNet network combines the functionality of Universal Remote I/O and Data Highway Plus. A ControlNet network has the following characteristics: Uses baud rates up to 5 Mbit/s Allows for up to 99 nodes Allows data transfer distances of up to 30 km (18.6 miles) using fiber optic media Example: ControlNet Network A SLC 500 processor with a 1747-SCNR ControlNet scanner module on a segment of a ControlNet network is shown in the following graphic: Ethernet/IP Network An EtherNet/IP network is a local area network (LAN) that provides communications between various devices at 10 Mbit/s. This network, available for SLC 5/05 processors, is the fastest SLC 500 communications option. An EtherNet/IP network has the following characteristics: Ethernet/IP Network Requires RJ45 connectors on both ends of a lOBaseT cable Requires a PC Ethernet communications card Uses baud rates from 10 Mbit/s to 100 Mbit/s Allows unlimited nodes on the network with a maximum of 24 SLC 5/05 (32K and 64K) processor connections Allows connections to the Internet via a 32-bit IP address Ethernet/IP Network