PACS IIDR ESTEC 01/02 March 2001 PACS Instrument Intermediate Design Review (IIDR) OGSE Reinhard Katterloher OGSE 1 PACS IIDR ESTEC 01/02 March 2001 Optical Ground Support Equipment (OGSE) • PACS OGSE consists of different cryostats, several cryogenic beam conditioning optics and infrared sources (i.e. OGSE –0, -1, -2, -3, -4) • OGSE 0 for FPU alignment/verification is under design and will be provided by KT/MPE • OGSE 1, 2 and 4 are required for detector module testing (will be provided by MPE, MPIA and LENS) • OGSE 3 and 4 are required for instrument performance verification and on-ground wavelength calibration (will be provided by MPE and LENS) • Use of the various OGSEs is required from June 01 – July 05 OGSE 2 PACS IIDR ESTEC 01/02 March 2001 OGSE 1 for Detector Module Performance Testing • OGSE 1 consists of a cryostat, optics and cryogenic BB source, it provides IR-background and signals within later operational range of photon flux • OGSE 1 will be located at MPE (2x) and at MPIA (1x) • MPE optics version „FIRSA“ was in use for EM1 – 6 tests and will be replaced by OGSE 1 before QM, FM, FS module testing starts • OGSE 1 is currently under final assembly (ready end March 01) • OGSE 1 is designed for simultaneous tests on 4 resp. 7 modules (depending on the electronics set-up used) OGSE 3 PACS IIDR ESTEC 01/02 March 2001 OGSE 1 connector block cryogenic blackbody 30-100K shutter test cryostat 4.2K baseplate ø400mm filter filter s-Ge:Ga detector module 1.7K baffle system connector 4.2K f/24 flat mirror 1.7K housing 4.2K housing connector block OGSE 1.7K heat sink 4 PACS IIDR ESTEC 01/02 March 2001 OGSE 1 light cone array 4.2K housing baffle system filter s-Ge:Ga detector module 1.7K 1.7K housing FEE 4.2K f/24 shutter 4.2K heat sink cryogenic blackbody 30-100K mirror therm. insulator 1.7K heat sink test cryostat 4.2K baseplate ø400mm LHe OGSE 5 PACS IIDR ESTEC 01/02 March 2001 OGSE 2 for Detector Module #8 spectral and proton-irradiation Tests • OGSE 2 consists of a LHe-dewar with optics (providing the right IR-background) and will be combined with – a tunable infrared source (OGSE 4) for the spectral investigations on the Ge:Ga pixels – OGSE 2 will be located at LENS for this test – a 100 MeV proton source for the high energy particle spike (transient) investigations – OGSE 2 will be located at PSI for this test • OGSE 2 is under manufacture (ready July 01) OGSE 6 PACS IIDR ESTEC 01/02 March 2001 OGSE2 detector test dewar ø283mm integrating sphere light cone PACS 1x16 detector module 1.7K and CRE 4.2K window f/18 paraboloid f/18 electrical connector aperture 1.7K ø3mm 1.7K ø20 TUFIR source 20K housing 1.7K 77K OGSE 7 PACS IIDR ESTEC 01/02 March 2001 OGSE 2 electrical connector aperture 1.7K ø3mm LHe 1.7K integrating sphere light cone window f/18 aperture ø10mm TUFIR input CRE 4K heat sink therm. insulator band pass filter PACS detector module 1.7K and CRE 4.2K baffle system light cone array f/24 2K 20K flat mirrors 77K detector test dewar ø=283mm h=700mm OGSE 8 PACS IIDR ESTEC 01/02 March 2001 OGSE 3 for instrument characterization Performance test and calibration activities with OGSE 3 will comprise: • Sensitivity calibration of the photometer and spectrometer sections of PACS • Wavelength calibration of PACS spectrometers • Characterization of spectral and spatial instrumental profiles for point sources • Use of other external sources (e.g. gas cell) in addition to TUFIR • OGSE 3 consists of a big test cryostat, telescope simulator, optics, BB and a window to feed-in outside cryostat IR-sources (OGSE 4 and others) • during functionality/performance testing (ILT1, ILT2) the optics and the cryogenic BB is used (OGSE 3 will be located at MPE) • during final wavelength calibration (ILT3) the optics and the tunable IR-source TUFIR is used (OGSE 3 will be located at LENS) • OGSE 3 is currently under design (preliminary concepts are shown), it has to be ready for use July 02 OGSE 9 PACS IIDR ESTEC 01/02 March 2001 PACS Test Cryostat with OGSE 3 OGSE 10 PACS IIDR ESTEC 01/02 March 2001 Top view of test cryostat and optical beam of PACS FPU and telescope simulator OGSE 11 PACS IIDR ESTEC 01/02 March 2001 Side view of test cryostat and optical beam of PACS FPU and telescope simulator OGSE 12 PACS IIDR ESTEC 01/02 March 2001 OGSE 3 Schematic PACS +Z FIRST focus ø240 +X pupil external focus light cone TUFIR input imaging mirror fold mirror OGSE integrating sphere 13 PACS IIDR ESTEC 01/02 March 2001 OGSE 3 Conceptual Design +Y integrating sphere 3 +Z pupil pupil imaging mirror test cryostat 960 cryofilters light cone flip mirror pos.1 TUFIR input integr. sphere cryostat windows external focus TUFIR input point source 2 point source mask BB focus fold mirror BB PACS OGSE FIRST focus ø240 14 PACS IIDR ESTEC 01/02 March 2001 OGSE 4 TUFIR Wavelength Calibrator • The tunable IR-source TUFIR is based on a third order mixing of coherent radiation emitted by two carbon dioxide lasers and microwaves generated by a synthesizer on a metal-insulator-metal diode. A complete coverage of the FIR spectral range is provided. The spectral calibration requirements for PACS are defined in PACS-ME-PL-003. • OGSE 4 is located at LENS • OGSE 4 is operational, adaptation of the beam to the specific needs of PACS is necessary (ILT3 test activities start May 03) OGSE 15 PACS IIDR ESTEC 01/02 March 2001 OGSE 4 Schematic representation of the TUFIR wavelength calibrator for PACS OGSE 16 PACS IIDR ESTEC 01/02 March 2001 Cryogenic Blackbody Source (above) and example of an Incandescent Line Source combined with a Water Vapour Absorption Cell (below) OGSE 17