Survey
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Hybrid Multi-Mode Microplate Reader Contents Synergy H4 – Hybrid Technology Key Features and Benefits Quadruple Grating Architecture Variable Band-Pass Selection High-Performance, Easy-to-Use Filter System Automated Z-Focusing Dual Reagent Dispenser Option Temperature Control System to 65°C Take3 Multi-Volume Multi-Sample Plate with 2 µL microspots Specifications and Summary Synergy™ H4: Hybrid Technology Filter-based optics: Use of dichroic mirrors increases sensitivity about 5x compared to filter-only optics Peak transmission for filters and mirrors is around 80%. Very efficient optical system Because of high amount of energy delivered to samples, high sensitivity can be obtained with short read times In summary, a fast and very sensitive optical system Synergy™ H4: Hybrid Technology Monochromator-based optics: Use of two gratings per monochromator provides smooth performance from 250 to 900 nm Very large range of applications, including spectral scanning Variable bandpass system adds flexibility In summary, an extremely flexible optical system Synergy™ H4: Hybrid Technology Filter Monochromator %CV Assay Window Z' Patent-pending design: Flexible monochromator system High-performance filter system Each with its strengths and weaknesses Extremely versatile instrument Contents Synergy H4 – Hybrid Technology Key Features and Benefits Quadruple Grating Architecture Variable Band-Pass Selection High-Performance, Easy-to-Use Filter System Automated Z-Focusing Dual Reagent Dispenser Option Temperature Control System to 65°C Take3™ Multi-Volume Plate with 2 µL microspots Specifications and Summary Contents Synergy H4 – Hybrid Technology Key Features and Benefits Quadruple Grating Architecture Variable Band-Pass Selection High-Performance, Easy-to-Use Filter System Automated Z-Focusing Dual Reagent Dispenser Option Temperature Control System to 65°C Take3™ Multi-Volume Plate with 2 µL microspots Specifications and Summary Contents Synergy H4 – Hybrid Technology Key Features and Benefits Quadruple Grating Architecture Variable Band-Pass Selection High-Performance, Easy-to-Use Filter System Automated Z-Focusing Dual Reagent Dispenser Option Temperature Control System to 65°C Take3™ Multi-Volume Plate with 2 µL microspots Specifications and Summary High-performance, easy-to-use filter system Dichroic mirrors: Easy side access Easy load/unload software function Filter wheels: Easy front access No tool required Easy load/unload software function Contents Synergy H4 – Hybrid Technology Key Features and Benefits Quadruple Grating Architecture Variable Band-Pass Selection High-Performance, Easy-to-Use Filter System Automated Z-Focusing Dual Reagent Dispenser Option Temperature Control System to 65°C Take3™ Multi-Volume Plate with 2 µL microspots Specifications and Summary Automated Z-Focusing Top fiber 300 µl 200 µl 100 µl If no Z-focusing available, performance issues in low volumes, or use of adapters required. 300 µl 200 µl 100 µl With Z-focusing, reading height can be precisely adjusted (100 µm resolution) for best performance on all plate types, and with all volumes. Contents Synergy H4 – Hybrid Technology Key Features and Benefits Quadruple Grating Architecture Variable Band-Pass Selection High-Performance, Easy-to-Use Filter System Automated Z-Focusing Dual Reagent Dispenser Option Temperature Control System to 65°C Take3™ Multi-Volume Plate with 2 µL microspots Specifications and Summary Dual Reagent Dispenser Option 35000 Fluorescence (RFU) 30000 25000 20000 15000 10000 5000 0:00:00 0:01:00 0:02:00 0:03:00 0:04:00 0:05:00 Time (minutes) Two reagent dispensers Baseline Response Volume range 5 µL - 1000 µL Enables dispense/read processes Trigger Reagent Ion channel assays, flash Injection luminescent assays, time-sensitive kinetic assays 0:06:00 0:07:00 0:08:00 Contents Synergy H4 – Hybrid Technology Key Features and Benefits Quadruple Grating Architecture Variable Band-Pass Selection High-Performance, Easy-to-Use Filter System Automated Z-Focusing Dual Reagent Dispenser Option Temperature Control System to 65°C Take3™ Multi-Volume Plate with 2 µL microspots Specifications and Summary Advanced 4-ZoneTM Temperature Control System 4 independent heaters with 4 monitoring sensors Precision: +/- 0.5°C at 37°C Range: RT to 65°C Enables applications with strict temperature uniformity requirements (e.g. ORAC assays) Enables high-temperature assays (e.g. Invader assays at 62°C) 1 3 2 4 Contents Synergy H4 – Hybrid Technology Key Features and Benefits Quadruple Grating Architecture Variable Band-Pass Selection High-Performance, Easy-to-Use Filter System Automated Z-Focusing Dual Reagent Dispenser Option Temperature Control System to 65°C Take3™ Multi-Volume Plate with 2 µL microspots Specifications and Summary Take3™ Multi-Volume Multi-Sample Plate with 2 µL microspots Sixteen 2 µL microspots Enables low volume A260 nucleic acid quantification dsDNA detection limit 2 ng/ µL Can also be used for A280 protein quantification, as well as fluorescence or luminescence detection Contents Synergy H4 – Hybrid Technology Key Features and Benefits Quadruple Grating Architecture Variable Band-Pass Selection High-Performance, Easy-to-Use Filter System Automated Z-Focusing Dual Reagent Dispenser Option Temperature Control System to 65°C Take3™ Multi-Volume Plate with 2 µL microspots Specifications and Summary Summary: Versatility Redefined Hybrid Technology: Monochromators and Filters Quadruple Grating Optical Architecture Variable Bandpass Selection Dichroic Mirrors and Filters for High Performance Dual Reagent Dispenser Option Temperature Control System to 65°C Take 3™ Multi-Volume Plate with 2 µL microspots Visit www.biotek.com for more information