Three phase system d L M Flux density B [T] N l A Generator for single phase Note Induction motor cannot start by itself. This problem is solved by introducing three phase system Current induces in the coil as the coil moves in the magnetic field Current produced at terminal Instead of using one coil only , three coils are used arranged in one axis with orientation of 120o each other. The coils are R-R1 , Y-Y1 and B-B1. The phases are measured in this sequence R-Y-B. I.e Y lags R by 120o , B lags Y by 120o. Finish R start eR L1 eY L2 eB L3 R1 Finish Y start Load Y1 Finish B start B1 The three winding can be represented by the above circuit. In this case we have six wires. The emf are represented by eR , eY, eB. e R E m sin t eY E m sin( t-120 ) eB E m sin( t-240 ) The circuit can be simplified as follows, where R1 can be connected to Y and Y1 can be connected to B. In this case the circuit is reduced to 4 wires. Finish R eRB1 eR eY eB eR start E m [sin t sin( t 120 ) sin( t 240 )] Em [sin t sin t cos120 cos t sin 120 Finish Y eY start sin t cos 240 cos t sin 240 ] R1 eR+eY+eB Y1 Finish B eB start B1 Em [sin t 0.5 sin t 0.866 cos t 0.5 sin t 0.866kost ] 0 Since the total emf is zero, R and B1 can be connected together, thus we arrive with delta connection system. Fig. B R Fig.A PL Y PM Y1 B Line conductors R1 PN B1 •Since the total emf is zero, R and B1 can be connected together as in Fig.A , thus we arrive with delta connection system as in Fig. C. •The direction of the emf can be referred to the emf waveform as in Fig. B where PL is +ve (R1R), PM is –ve (Y-Y1) and PN is –ve (B-B1). Fig. C R eY Y1 Y eR B1 R1 B eB •R1, Y1 and B1 are connected together. •As the e.m.f generated are assumed in positive direction , therefore the current directions are also considered as flowing in the positive direction. •The current in the common wire (MN) is equal to the sum of the generated currents. i.e iR+iY+iB . •This arrangement is called four –wire star-connected system. The point N refers to star point or neutral point. R iR R1 Y iY Y1 B N M iR+iY+iB iB B1 Generator 1 Load The instantaneous current in loads L1 , L2 and L3 are R R1 iY I m sin( t-120 ) N Y1 B1 i B I m sin( t-240 ) B i N i R iY i B I m [sin t sin( t 120 ) sin( t 240 )] 0 Y Y iY iB B iR+iY+iB L3 L2 L1 Line conductors i R I m sin t R iR Three-wire star-connected system with balanced load For balanced loads, the fourth wire carries no current , so it can be dispensed 8.66A 2.6A 5A R L R1 10A N Y1 0 9.7A Y L B1 B L 7.1A 5A 8.66A generator coils a b c balanced load phase and line current in ampere Instantaneous currents’ waveform for iR, iY and iB in a balanced three-phase system. •VRY, VYB and VBR are called line voltage •VR, VY and VB are called phase voltage R VRY VBR N Y From Kirchoff voltage law we have VB VRY VR VY VR (VY ) VYB VY VB VY (VB ) VBR VB VR VB (VR ) IR VR B VBR IY VY VYB IB -VY VB VRY VR -VR In phasor diagram VY VYB -VB For balanced load VR , VY and VB are equaled but out of phase VR = VP30; VRY = VL30; VY = VP-90; VYB = VL-90; VB = VP150; VBR = VL150; VRY 2VR cos 30o 3 V 3 V 3 V VBR 2VB cos 30o P P P VRY VR -VR VY therefore VYB 2VY cos 30o VBR -VY VB VYB -VB then VL 3 V and IL IP P IR •IR, IY and IB are called line current •I1, I2 and I3 are called phase current From Kirchoff current law we have I1 IY I3 VP Y VL I R I1 I3 I1 ( I 3 ) I2 IY I2 I1 I 2 (I1 ) IB IR I B I 3 I 2 I 3 ( I 2 ) In phasor diagram R I1 -I3 -I2 IB I3 I2 -I1 IY B Since the loads are balanced, the magnitude of currents are equaled but 120o out of phase. i.e I1 =I2=I3 ,=IP Therefore:- IR = IL30; I1 = VP30; IY = IL-90; I2 = VP-90; IB = IL150; I3 = VP150; Where IP is a phase current and IL is a line current IR I R 2 I1 cos 30 ( 3 ) I P I1 I Y 2 I 2 cos 30 ( 3 ) I P I B 2I 3 cos 30 Thus IR=IY=IB = IL 3I -I3 -I2 IB P I3 I2 -I1 IY Hence IL 3 I P VL VP Unbalanced load In a three-phase four-wire system the line voltage is 400V and non-inductive loads of 5 kW, 8 kW and 10 kW are connected between the three conductors and the neutral. Calculate: (a) the current in each phase (b) the current in the neutral conductor. Voltage to neutral VP VL 400 230V 3 3 Current in 10kW resistor PR 10 4 IR 43.5 A VP 230 Current in 8kW resistor PY 8 103 IY 34.8 A VP 230 Current in 5kW resistor PB 5 103 IB 21.7 A VP 230 IR INV IBH IN IYH IBV IYV IB IY INH Resolve the current components into horizontal and vertical components. I H IY cos 30 I B cos 30o 0.86634.8 21.7 11.3 A IV I R I Y cos 60 I B cos 60o 43.5 0.5(34.8 21.7) 13.0 A I N I NH I NV 11.32 13.02 17.2 A 2 2 A delta –connected load is arranged as in Figure below. The supply voltage is 400V at 50Hz. Calculate: (a)The phase currents; (b)The line currents. IR R 400V 400V Y 400V R1=100 I1 IY R2=20 I2 IB X2=60 C=30F I3 B (a) I1 VRY 400 4A R1 100 I1 is in phase with VRY since there is only resistor in the branch In branch between YB , there are two components , R2 and X2 I2 VYB 400 6.32 A 2 2 ZY 20 60 ZY R 2 X 2 2 2 X Y tan 1 2 R2 20 60 2 IR 400 1 /(2 50 30 10 6 ) 90 o 90 3.77 A I1 -I3 60 tan 1 71 34' 20 In the branch RB , only capacitor in it , so the XC is -90 out of phase. V I 3 BR XC VRY 2 30o 90o 71o34' VBR 30o I3 I2 VYB (b) I R I1 I 3 I R2 I12 2 I1 I 3 cos I 32 =30o I1 I R2 4.0 24.03.77 cos 30o 3.77 56.3 2 2 I R 7.5 A 120o = 71o 34’ -60o= 11o 34’ I Y I 2 I1 2 2 -I1 I2 I I 2I1I 2 cos I 2 Y 2 1 I Y2 6.32 24.06.32 cos11o34'4.0 105.5 2 IY 10.3 A 60o 71o 34' 2 IY = 180-30o-11o 34’ = 138o 34’ I B I3 I 2 I B2 I 32 2 I 3 I 2 cos I 22 I B2 6.32 23.77 6.32 cos 138o 26'3.77 18.5 2 2 -I2 I B 4.3 A I2 90o 11o 34' 71o 34' 30o I3 I2 Power in three phase Active power per phase = IPVP x power factor Total active power= 3VPIP x power factor P 3VP I P cos If IL and VL are rms values for line current and line voltage respectively. Then for delta () connection: VP = VL and IP = IL/3. therefore: P 3VL I L cos For star connection () : VP = VL/3 and IP = IL. therefore: P 3VL I L cos A three-phase motor operating off a 400V system is developing 20kW at an efficiency of 0.87 p.u and a power factor of 0.82. Calculate: (a)The line current; (b)The phase current if the windings are delta-connected. (a) Since Efficiency output power in watts input power in watts output power in watts 3 I LVL p. f 0.87 20 1000 3 I L 400 0.82 And line current =IL=40.0A (b) For a delta-connected winding line current 40.0 Phase current 23.1A 3 3 Three identical coils, each having a resistance of 20 and an inductance of 0.5 H connected in (a) star and (b) delta to a three phase supply of 400 V; 50 Hz. Calculate the current and the total power absorbed by both method of connections. First of all calculating the impedance of the coils X P 2 50 0.5 157 R P 20 Z P RP jX P RP X P 2 2 XP where tan RP 157 20 157 tan 15883 20 2 2 1 cos cos 83 0.1264 1 Star-connection 20 400V 400V 400 / 3 0.5H N 0.5H 400V 20 0.5H 20 Since it is a balanced load VP 400 231V 3 IP IL VP 231 1.46A Z P 158 Power absorbed P 3VL I L cos 3 400 1.46 0.1264 128W Star connection 400V 20 400V 400V VP VL 400 V 0.5H 20 0.5H 20 0.5H VP 400 IP 4.38A Z P 158 P 3VL I L cos 3 400 4.38 0.1264 383W A balanced three phase load connected in star, each phase consists of resistance of 100 paralleled with a capacitance of 31.8 F. The load is connected to a three phase supply of 415 V; 50 Hz. Calculate: (a) the line current; (b) the power absorbed; (c) total kVA; (d) power factor . 415 VP VL 3 415 3 240 V Admittance of the load 1 1 YP R P XP where XP 1 jC 1 1 jC j2 50 31.8 10 6 (0.01 j0.01)S RP 100 Line current I L I P VPYP 240(0.01 j0.01) 2.4 j 2.4 3.3945 Volt-ampere per phase 240 3 . 39 45 814 . 4 45 PVA VP I P Active power per phase PPA 814.4 cos 45 576 Total active power PA 3 576 1.728 kW (b) P j 814 . 4 sin 45 j576 Reactive power per phase PR Total reactive power (c) (d) Total volt-ampere PR j3 576 j1.728 kW 3 814 .4 2.44 kVA Power Factor = cos = cos 45 = 0.707 (leading) A three phase star-connected system having a phase voltage of 230V and loads consist of non reactive resistance of 4 , 5 and 6 respectively. Calculate:(a) the current in each phase conductor (b) the current in neutral conductor and (c) total power absorbed. 230 I 4 57.5A 4 230 I 5 46A 5 230 I 6 38.3A 6 38.3 A 57.5 A (b) 46 A X-component = 46 cos 30 + 38.3 cos 30 - 57.5 = 15.5 A Y-component = 46 sin 30 - 38.3 sin 30 = 3.9 A Therefore (c) I N 15.5 2 3.9 2 16A P 230 57.5 46 38.3 32.61kW