Download 2148-2155 August 25, 2008

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Document related concepts
no text concepts found
Transcript
High spatial resolution myocardial perfusion cardiac
magnetic resonance for the detection of coronary artery
disease
by Sven Plein, Sebastian Kozerke, Daniel Suerder, Thomas F. Luescher, John P.
Greenwood, Peter Boesiger, and Juerg Schwitter
EHJ
Volume 29(17):2148-2155
August 25, 2008
Published on behalf of the European Society of Cardiology. All rights reserved. © The Author
2008. For permissions please email: [email protected]
Receiver–operating characteristics curve for the ability of the cardiac magnetic resonance
perfusion score to detect coronary artery disease >50%.
Sven Plein et al. Eur Heart J 2008;29:2148-2155
Published on behalf of the European Society of Cardiology. All rights reserved. © The Author
2008. For permissions please email: [email protected]
Case example: 47-year-old male with previous inferior myocardial infarction, in whom
subsequent coronary angiography showed chronic total occlusion of the right coronary artery
and a patent proximal left anterior descending artery stent.
Sven Plein et al. Eur Heart J 2008;29:2148-2155
Published on behalf of the European Society of Cardiology. All rights reserved. © The Author
2008. For permissions please email: [email protected]
Case examples of right ventricular (RV) perfusion.
Sven Plein et al. Eur Heart J 2008;29:2148-2155
Published on behalf of the European Society of Cardiology. All rights reserved. © The Author
2008. For permissions please email: [email protected]
Case example: myocardial perfusion-cardiac magnetic resonance study of a 56-year-old patient
with 90% stenosis of the left anterior descending coronary artery on subsequent coronary
angiography.
Sven Plein et al. Eur Heart J 2008;29:2148-2155
Published on behalf of the European Society of Cardiology. All rights reserved. © The Author
2008. For permissions please email: [email protected]
Respiratory and k–t reconstruction-related artefact: perfusion-cardiac magnetic resonance
images from a patient who was unable to hold his breath during the stress-perfusion
acquisition.
Sven Plein et al. Eur Heart J 2008;29:2148-2155
Published on behalf of the European Society of Cardiology. All rights reserved. © The Author
2008. For permissions please email: [email protected]
Related documents