Download DaqBook/2020 WaveBook/516

Document related concepts

Heterodyne wikipedia , lookup

Phone connector (audio) wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Oscilloscope wikipedia , lookup

Oscilloscope types wikipedia , lookup

Analog-to-digital converter wikipedia , lookup

Rectiverter wikipedia , lookup

Oscilloscope history wikipedia , lookup

Tektronix analog oscilloscopes wikipedia , lookup

Opto-isolator wikipedia , lookup

Transcript
DaqBook, DaqScan,
DaqLab, Personal Daq,
DaqBoard USB Overview
John Rys
Product Support Engineer
Ethernet DaqBooks
DaqBook/2001 and /2005
• The /2001 and /2005 models provide:
• P1, P2, P3 on the rear panel (vs. front)
• Extended temperature operation (-30˚C to +70˚C) (
+70˚C)
• Slim 1U high package
DaqBook/2001 and /2005
• DaqBook/2001 and /2005 are “building blocks” of a
modular data acquisition system using DBK options
DaqBook/2020
• The /2020 offers volts, thermocouples frequency, analog
output, and digital I/O – all-in-one-box!
DaqBook/2020 Features
Thermocouple Measurements
• 14 TC inputs via
front-panel mini-TC jacks
• Any TC type can install into any input
• TCs are scanned at 200 kHz/channel
• Additional TC can be added via DBK80 series and
DBK90
DaqBook/2020 Features
Voltage Measurements
• 16 differential volts inputs
via front-panel BNC
connectors
• 13 programmable input ranges from
10 V to 156 mV
• 200 kHz, 16-bit measurements
DaqBook/2020 Features
• Four 16-bit, 100 kHz DAC outputs via front-panel
BNC connectors
• Four 16-bit, 10 MHz frequency inputs via front-panel
BNC connectors (can be combined into 32-bit counters)
• Two 16-bit, 1 MHz timer outputs via front-panel
BNC connectors
• External Trigger Input and External Clock input via
front-panel BNC connectors
DaqBook/2020
• Rear-panel P1 connector accepts up to 14 DBK options
(presuming 16 ch options)
• Rear-panel P2 connector provides 24 digital I/O
(expandable up to 256 ch with DBK20 family options)
P1 for analog
expansion
P2 for digital I/O
10/100 base T
Ethernet
DC power input
SYNC connector
DaqBook/2020
• Built-in 10/100BaseT Ethernet
• SYNC connectors for multi-box applications
DaqBook/2020 vs WaveBook/516E
DaqBook/2020
Speed
WaveBook/516
200 kHz
1 MHz
Voltage channels
16
8
TC inputs
14
0
Analog outputs
4
0
Frequency inputs
4
0
Digital I/O
24
16
Expansion capacity
256
72
DBK90
• 56 TC channels for DaqBook systems
(not DaqBoard or LogBook compatible)
DBK90
• Any TC type can be connected to any input using
standard mini TC connectors
• Multiple DBK90s can be attached together
(without cables)
• Mounting brackets are available to attach DBK90
to DaqBooks
DBK90
• Rack-mount kit for large-channel applications
DBK90
• Reading rate with DBK90 is 1 msec per channel
(vs 5 µsec for other DBK options)
• Other channels in the system, such as volts, are
measured at 5 µsec per channel
• Up to 896 DBK90 channels can be connected
to one DaqBook
DaqScan/2000 Series
DaqScan/2000 Applications
• Add DBK207 for isolated volts inputs
• Add DBK207/CJC for isolated TC inputs
DaqScanApplications/2000
• Add DBK208 and DBK210 for isolated high-voltage
digital inputs and control outputs
DaqScan/2000 Applications
• Add DBK85 for 16 differential voltage inputs
DBK85 with rack-mount kit
DaqScan/2000 Applications
• Add DBK60 for custom applications using DBK cards
DBK60 with cards installed
DaqScan/2000 Series Features
• 2 DaqScan models provide the same analog I/O,
digital I/O, and frequency I/O as the DaqBook/2000
• Depending on the model, P1, P2, and P3 are provided
on the rear panel for signal connections
DaqScan/2000 vs DaqBook
• 1U high, 19” rack enclosure vs. portable package
• Operates in 0˚ to 50˚C (vs -30˚ to +70˚C)
• AC powered (vs DC)
• Low-cost digital I/O –only version
• Always used along with instruments from other suppliers
• Continuous data transfer from the DaqScan to the PC
• Supported with IVI- COM drivers
DaqScan/2000 Series Software
• Most customers will write their own application in either
NI LabView, DASYLab, Visual Basic, or C++
• DaqView is included for set-up and signal verification
DaqLab/2000 Series
Two DBK expansion slots
AC powered
Removable screw terminals
DaqLab/2000 Series Features
• 16-bit, 200 kHz A/D
• 8 front-panel volts inputs + P1 on rear for analog
expansion
• 4 front-panel frequency inputs (16-bit, 10 MHz)
DaqLab/2000 Series Features
• 2 internal expansion slots for analog or digital DBK
expansion cards
• 6 front-panel digital I/O lines
• 24 digital I/O via P2 on rear
DaqLab/2000 Series Features
• Two DaqLab/2000 Series products:
/2001 has four 16-bit, 100 kHz analog outputs
/2005 has no analog outputs
• Includes DaqView and drivers for NI LabVIEW,
DASYLab, C++, Visual Basic, MATLAB
DBK Signal Conditioner
Solution for Physical Test Applications
DBK for Analog Output
• DBK2 – 4 channel card
– 14 bit DAC
– Adds additional analog outputs
– For static output or reference out.
(Not a waveform generator)
– Output set at the beginning of the acquisition.
DBK for Acceleration
• DBK4
– 2 channels
– AC/DC coupling
– Supplies ICP power
– Software selectable 8 pole Butterworth filter
– Simultaneous Sample and Hold
DBK for Current Loop “Control”
• DBK5 – 4 channel card
– 14 bit DAC
– Adds additional analog outputs
– For static output or reference out
(not a waveform generator)
– Output set at the beginning of the acquisition
DBK for Speed, RPM, Tachometers, etc.
• DBK7 converts pulse to DC voltage
– 4 channels
– 1Hz to 100 kHz (analog input)
– 1 Hz to 950 kHz (digital input)
– Inputs from 50 mV to 80 Vp-p
DBK’s for Temperature
• DBK9 - RTD
– 8 channels of 100, 500 or
1000 Ohm RTD inputs
– 3 or 4 wire configuration
– Internal excitation source
DBK Expansion Chassis
• DBK10 – holds 3 cards
• DBK41 – holds 10 cards
– Reduces cabling issues
• DBK60 – holds three cards
– Uses the DBK600 series connector panels for user customization
DBK for Current Loops
• DBK15
– 16 channels
– Header for 250 ohm resistor
to convert 4-20 mA to 1 to 5 V
– Also good for straight voltages
DBK’s for Strain, Load & Pressure
• 2 channel DBK16, and 8 channel DBK43A
• Quarter, half and full bridge gages.
• Strain based load and pressure sensors.
• Built in filters
• Handles 120 to 1000 Ohm bridges
DBK for Simutaneous Sample and Hold
• DBK17 and DBK45
– 4 channels
– Eliminates time skew between channels
– User adjustable gain
– Low noise (instrumentation amp per channel)
– DBK45 includes filtering
DBK for Filtering
• DBK18 and DBK45
– 4 channels
– User adjustable gain
– Low noise (instrumentation amp/ch)
– 5, 10, 100, 500 and 1 kHz filters factory available (Butterworth)
– User can create their own RC combination to change to corner
frequency
– DBK45 also has SSH
DBK for Digital Inputs (P2)
• DBK20 & DBK21
– Adds 48 additional digital inputs in groups of 8 bits
– Screw terminal or DB37
DBK for Digital Inputs (P2)
• DBK23 – Optically Isolated
– 24 inputs per module
– 3 to 30V inputs
– Monitor switches, contacts or other on/off inputs
DBK Digital Outputs (P2)
• DBK24 – Optically Isolated to 500 V
– Switches up to 60 V
– 24 channels
• DBK25 – 8 Channel Relay card
– 8 dry contact relays
– Relays latch into position
– Preset power-up state
DBK Battery Options
• DBK34A – UPS / Battery pack
– Connects to an existing AC/DC source and supplies power when
the main source fails.
DBK for 5B modules
• DBK42 – 16 slot module
– Connector panel is separate
• DBK44 – 2 channel card
DBK’s for Thermocouple Measurements
• DBK81, DBK82, DBK83, DBK84
– 7 or 14 channel thermocouple inputs
– 4 Hz, low noise front-end
– Newest addition to the DBK line.
DBK65
• 8-channel module for attaching powered
transducers to DaqBooks and LogBooks
DBK65 Applications
• Removable front-panel screw terminals for connection of
2, 3, 4, or 6 wire transducers
• Built-in power supply provides transducer power of 5, 10,
15, and 24 V, jumper-selectable per-channel
(100 mA max/channel, set via internal jumpers)
• Other voltages between 5 and 20 V are possible if user
installs an internal resistor
DBK65 Wiring Example
• 2-wire voltage measurement
DBK65 Wiring Example
• 2-wire transducer with 4 to 20 mA output
DBK65 wiring example
• 4-wire bridge-based transducer
DBK85
• 16 differential voltage inputs for 2000 series products
DBK85
• DBK80 card in a box with connectors
• 156 mV to 10 VFS input
• BNC signal connection
DBK55
• 8-channel frequency input module for all DaqBook and
LogBook products
DBK55
• 8 frequency inputs via front-panel BNCs
• 1 Hz to 950 kHz range
• 12-bit resolution
• AC-coupled inputs up to 80V p-p
• Same as two DBK7 cards
Personal Daq/3000
• USB 2.0 interface
• Stretched Pdaq package
with removable
screw-terminal connections
• USB powered
• Includes DaqView/3000 software
DaqBoard/3000 USB
• USB 2.0 interface
• Stretched Pdaq package
with removable
screw-terminal connections
• USB powered
• Includes DaqView/3000 software
Personal Daq/3000
• 1 MHz, 16-bit A/D
• 16 SE/8 DIFF analog inputs
• 24 digital I/O
• 0, 2 or 4: 1 MHz, 16-bit analog outputs
• 4 counters 32-bit, 20 MHz
• 2 timers
– 12 MHz scanning of digital input lines
– Up to 12 MHz pattern generation
– Digital I/O & Counters synchronous with analog I/O, but consume NO time slot in
scan sequencer
– users can scan 1 analog input at full 1 MHz along with digital inputs and counters
– Quadrature encoder capable counter inputs
Personal Daq Applications
• Portable volts, temperature (TC), frequency, pulse
counting, duty cycle and digital I/O
• Lab/desktop measurements
(a more-transportable solution than PC plug-in boards)
Software
• Personal DaqView
– Links to Excel
– Exports data to several popular formats
• Visual Basic and C++ drivers
• DASYLab drivers
• NI LabVIEW drivers