* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download DaqBook/2020 WaveBook/516
Phone connector (audio) wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Oscilloscope wikipedia , lookup
Oscilloscope types wikipedia , lookup
Analog-to-digital converter wikipedia , lookup
Rectiverter wikipedia , lookup
Oscilloscope history wikipedia , lookup
DaqBook, DaqScan, DaqLab, Personal Daq, DaqBoard USB Overview John Rys Product Support Engineer Ethernet DaqBooks DaqBook/2001 and /2005 • The /2001 and /2005 models provide: • P1, P2, P3 on the rear panel (vs. front) • Extended temperature operation (-30˚C to +70˚C) ( +70˚C) • Slim 1U high package DaqBook/2001 and /2005 • DaqBook/2001 and /2005 are “building blocks” of a modular data acquisition system using DBK options DaqBook/2020 • The /2020 offers volts, thermocouples frequency, analog output, and digital I/O – all-in-one-box! DaqBook/2020 Features Thermocouple Measurements • 14 TC inputs via front-panel mini-TC jacks • Any TC type can install into any input • TCs are scanned at 200 kHz/channel • Additional TC can be added via DBK80 series and DBK90 DaqBook/2020 Features Voltage Measurements • 16 differential volts inputs via front-panel BNC connectors • 13 programmable input ranges from 10 V to 156 mV • 200 kHz, 16-bit measurements DaqBook/2020 Features • Four 16-bit, 100 kHz DAC outputs via front-panel BNC connectors • Four 16-bit, 10 MHz frequency inputs via front-panel BNC connectors (can be combined into 32-bit counters) • Two 16-bit, 1 MHz timer outputs via front-panel BNC connectors • External Trigger Input and External Clock input via front-panel BNC connectors DaqBook/2020 • Rear-panel P1 connector accepts up to 14 DBK options (presuming 16 ch options) • Rear-panel P2 connector provides 24 digital I/O (expandable up to 256 ch with DBK20 family options) P1 for analog expansion P2 for digital I/O 10/100 base T Ethernet DC power input SYNC connector DaqBook/2020 • Built-in 10/100BaseT Ethernet • SYNC connectors for multi-box applications DaqBook/2020 vs WaveBook/516E DaqBook/2020 Speed WaveBook/516 200 kHz 1 MHz Voltage channels 16 8 TC inputs 14 0 Analog outputs 4 0 Frequency inputs 4 0 Digital I/O 24 16 Expansion capacity 256 72 DBK90 • 56 TC channels for DaqBook systems (not DaqBoard or LogBook compatible) DBK90 • Any TC type can be connected to any input using standard mini TC connectors • Multiple DBK90s can be attached together (without cables) • Mounting brackets are available to attach DBK90 to DaqBooks DBK90 • Rack-mount kit for large-channel applications DBK90 • Reading rate with DBK90 is 1 msec per channel (vs 5 µsec for other DBK options) • Other channels in the system, such as volts, are measured at 5 µsec per channel • Up to 896 DBK90 channels can be connected to one DaqBook DaqScan/2000 Series DaqScan/2000 Applications • Add DBK207 for isolated volts inputs • Add DBK207/CJC for isolated TC inputs DaqScanApplications/2000 • Add DBK208 and DBK210 for isolated high-voltage digital inputs and control outputs DaqScan/2000 Applications • Add DBK85 for 16 differential voltage inputs DBK85 with rack-mount kit DaqScan/2000 Applications • Add DBK60 for custom applications using DBK cards DBK60 with cards installed DaqScan/2000 Series Features • 2 DaqScan models provide the same analog I/O, digital I/O, and frequency I/O as the DaqBook/2000 • Depending on the model, P1, P2, and P3 are provided on the rear panel for signal connections DaqScan/2000 vs DaqBook • 1U high, 19” rack enclosure vs. portable package • Operates in 0˚ to 50˚C (vs -30˚ to +70˚C) • AC powered (vs DC) • Low-cost digital I/O –only version • Always used along with instruments from other suppliers • Continuous data transfer from the DaqScan to the PC • Supported with IVI- COM drivers DaqScan/2000 Series Software • Most customers will write their own application in either NI LabView, DASYLab, Visual Basic, or C++ • DaqView is included for set-up and signal verification DaqLab/2000 Series Two DBK expansion slots AC powered Removable screw terminals DaqLab/2000 Series Features • 16-bit, 200 kHz A/D • 8 front-panel volts inputs + P1 on rear for analog expansion • 4 front-panel frequency inputs (16-bit, 10 MHz) DaqLab/2000 Series Features • 2 internal expansion slots for analog or digital DBK expansion cards • 6 front-panel digital I/O lines • 24 digital I/O via P2 on rear DaqLab/2000 Series Features • Two DaqLab/2000 Series products: /2001 has four 16-bit, 100 kHz analog outputs /2005 has no analog outputs • Includes DaqView and drivers for NI LabVIEW, DASYLab, C++, Visual Basic, MATLAB DBK Signal Conditioner Solution for Physical Test Applications DBK for Analog Output • DBK2 – 4 channel card – 14 bit DAC – Adds additional analog outputs – For static output or reference out. (Not a waveform generator) – Output set at the beginning of the acquisition. DBK for Acceleration • DBK4 – 2 channels – AC/DC coupling – Supplies ICP power – Software selectable 8 pole Butterworth filter – Simultaneous Sample and Hold DBK for Current Loop “Control” • DBK5 – 4 channel card – 14 bit DAC – Adds additional analog outputs – For static output or reference out (not a waveform generator) – Output set at the beginning of the acquisition DBK for Speed, RPM, Tachometers, etc. • DBK7 converts pulse to DC voltage – 4 channels – 1Hz to 100 kHz (analog input) – 1 Hz to 950 kHz (digital input) – Inputs from 50 mV to 80 Vp-p DBK’s for Temperature • DBK9 - RTD – 8 channels of 100, 500 or 1000 Ohm RTD inputs – 3 or 4 wire configuration – Internal excitation source DBK Expansion Chassis • DBK10 – holds 3 cards • DBK41 – holds 10 cards – Reduces cabling issues • DBK60 – holds three cards – Uses the DBK600 series connector panels for user customization DBK for Current Loops • DBK15 – 16 channels – Header for 250 ohm resistor to convert 4-20 mA to 1 to 5 V – Also good for straight voltages DBK’s for Strain, Load & Pressure • 2 channel DBK16, and 8 channel DBK43A • Quarter, half and full bridge gages. • Strain based load and pressure sensors. • Built in filters • Handles 120 to 1000 Ohm bridges DBK for Simutaneous Sample and Hold • DBK17 and DBK45 – 4 channels – Eliminates time skew between channels – User adjustable gain – Low noise (instrumentation amp per channel) – DBK45 includes filtering DBK for Filtering • DBK18 and DBK45 – 4 channels – User adjustable gain – Low noise (instrumentation amp/ch) – 5, 10, 100, 500 and 1 kHz filters factory available (Butterworth) – User can create their own RC combination to change to corner frequency – DBK45 also has SSH DBK for Digital Inputs (P2) • DBK20 & DBK21 – Adds 48 additional digital inputs in groups of 8 bits – Screw terminal or DB37 DBK for Digital Inputs (P2) • DBK23 – Optically Isolated – 24 inputs per module – 3 to 30V inputs – Monitor switches, contacts or other on/off inputs DBK Digital Outputs (P2) • DBK24 – Optically Isolated to 500 V – Switches up to 60 V – 24 channels • DBK25 – 8 Channel Relay card – 8 dry contact relays – Relays latch into position – Preset power-up state DBK Battery Options • DBK34A – UPS / Battery pack – Connects to an existing AC/DC source and supplies power when the main source fails. DBK for 5B modules • DBK42 – 16 slot module – Connector panel is separate • DBK44 – 2 channel card DBK’s for Thermocouple Measurements • DBK81, DBK82, DBK83, DBK84 – 7 or 14 channel thermocouple inputs – 4 Hz, low noise front-end – Newest addition to the DBK line. DBK65 • 8-channel module for attaching powered transducers to DaqBooks and LogBooks DBK65 Applications • Removable front-panel screw terminals for connection of 2, 3, 4, or 6 wire transducers • Built-in power supply provides transducer power of 5, 10, 15, and 24 V, jumper-selectable per-channel (100 mA max/channel, set via internal jumpers) • Other voltages between 5 and 20 V are possible if user installs an internal resistor DBK65 Wiring Example • 2-wire voltage measurement DBK65 Wiring Example • 2-wire transducer with 4 to 20 mA output DBK65 wiring example • 4-wire bridge-based transducer DBK85 • 16 differential voltage inputs for 2000 series products DBK85 • DBK80 card in a box with connectors • 156 mV to 10 VFS input • BNC signal connection DBK55 • 8-channel frequency input module for all DaqBook and LogBook products DBK55 • 8 frequency inputs via front-panel BNCs • 1 Hz to 950 kHz range • 12-bit resolution • AC-coupled inputs up to 80V p-p • Same as two DBK7 cards Personal Daq/3000 • USB 2.0 interface • Stretched Pdaq package with removable screw-terminal connections • USB powered • Includes DaqView/3000 software DaqBoard/3000 USB • USB 2.0 interface • Stretched Pdaq package with removable screw-terminal connections • USB powered • Includes DaqView/3000 software Personal Daq/3000 • 1 MHz, 16-bit A/D • 16 SE/8 DIFF analog inputs • 24 digital I/O • 0, 2 or 4: 1 MHz, 16-bit analog outputs • 4 counters 32-bit, 20 MHz • 2 timers – 12 MHz scanning of digital input lines – Up to 12 MHz pattern generation – Digital I/O & Counters synchronous with analog I/O, but consume NO time slot in scan sequencer – users can scan 1 analog input at full 1 MHz along with digital inputs and counters – Quadrature encoder capable counter inputs Personal Daq Applications • Portable volts, temperature (TC), frequency, pulse counting, duty cycle and digital I/O • Lab/desktop measurements (a more-transportable solution than PC plug-in boards) Software • Personal DaqView – Links to Excel – Exports data to several popular formats • Visual Basic and C++ drivers • DASYLab drivers • NI LabVIEW drivers