Download training workshop on pharmaceutical quality, good manufacturing

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Document related concepts

Environmental impact of pharmaceuticals and personal care products wikipedia , lookup

Polysubstance dependence wikipedia , lookup

Drug interaction wikipedia , lookup

Prescription costs wikipedia , lookup

Plateau principle wikipedia , lookup

Medication wikipedia , lookup

Bad Pharma wikipedia , lookup

Compounding wikipedia , lookup

Pharmaceutical marketing wikipedia , lookup

Drug design wikipedia , lookup

Pharmaceutical industry wikipedia , lookup

Pharmacognosy wikipedia , lookup

Drug discovery wikipedia , lookup

Theralizumab wikipedia , lookup

Biosimilar wikipedia , lookup

Pharmacokinetics wikipedia , lookup

Bilastine wikipedia , lookup

Transcript
WORKSHOP ON
PREQUALIFICATION OF ARV:
BIOEQUIVALENCE
Introduction to the Discussion
of Bioequivalence Study
Design and Conduct
Presented by
Hans Kemmler
Consultant to WHO
Swissmedic (Swiss drug regulatory authority)
Hanoi, 2006-19-01
1
Background:
First Product to Market

Innovator’s Product

Quality

Safety and efficacy
– Based on extensive clinical trials
– Expensive
– Time consuming
Hanoi, 2006-19-01
2
Background:
Other products with same
medicinal ingredient

Subsequent-entry products

Generic products

Multisource products

How do these products gain
marketing authorization?
Hanoi, 2006-19-01
3
Pharmaceutical equivalence

Same amount of the same active
pharmaceutical ingredient
– Salts, esters

Same dosage form
– Comparable dosage forms
– e.g., tablet vs. capsule

Same route of administration

Is pharmaceutical equivalence enough?
Hanoi, 2006-19-01
4
Sometimes pharmaceutical
equivalence is enough

Aqueous solutions
–
–
–
–
–
–
Intravenous solutions
Intramuscular, subcutaneous
Oral solutions
Otic or ophthalmic solutions
Topical preparations
Solutions for nasal administration

Powders for reconstitution as solution

Gases
Hanoi, 2006-19-01
5
Sometimes it is not enough

Pharmaceutical equivalence by itself
does not necessarily imply
therapeutic equivalence

Therapeutic equivalence:
– Pharmaceutically equivalent
– Same safety and efficacy profiles after
administration of same dose
Hanoi, 2006-19-01
6
Pharmaceutical Equivalents
Reference
Test
Possible Differences

Drug particle size

Excipients

Manufacturing
Equipment or
Process

Site of manufacture
Could lead to differences in product performance in vivo
Hanoi, 2006-19-01
7
Additional data is required

Oral immediate release products with
systemic action
– Generally required for solid oral
dosage forms
• Critical use
• Narrow therapeutic range
• Bioavailability problems associated with
the active ingredient
• Problematic polymorphism, excipient
interaction, or sensitivity to manufacturing
processes
Hanoi, 2006-19-01
8
Additional data is required

Oral modified release products with
systemic action

Fixed dose combination products with
systemic action
– When at least one component requires study

Non-oral / non-parental products with
systemic action

Non-solution products with non-systemic
action
Hanoi, 2006-19-01
9
Marketing authorization of
multisource products

Extensive clinical trials to
demonstrate safety and efficacy
– Interchangeability?

Demonstration of equivalence to
reference (comparator) product
– Interchangeability
– Therapeutic equivalence
Hanoi, 2006-19-01
10
Marketing authorization
through equivalence

Suitable methods for assessing
equivalence:
– Comparative pharmacokinetic studies
– Comparative pharmacodynamic
studies
– Comparative clinical trials
– Comparative in vitro tests
Hanoi, 2006-19-01
11
Comparative Pharmacokinetic
Studies

In vivo measurement of active
ingredient

“Some” relationship between
concentration and safety/efficacy

Product performance is the key

Comparative bioavailability
Hanoi, 2006-19-01
12
Bioavailability

The rate and extent to which a substance or
its active moiety is delivered from a
pharmaceutical form and becomes available
in the general circulation.”
Reference:
intravenous administration = 100% bioavailability
Hanoi, 2006-19-01
13
Important Pharmacokinetic
Parameters

AUC: area under the concentration-time
curve  measure of the extent of
bioavailability

Cmax: the observed maximum concentration
of drug  measure of both the rate of
absorption and the extent of bioavailability

tmax: the time after administration of drug at
which Cmax is observed  measure of the
rate of absorption
Hanoi, 2006-19-01
14
Plasma concentration time
profile
concentration
Cmax
AUC
time
Tmax
Hanoi, 2006-19-01
15
Bioequivalence
Two products are bioequivalent if

they are pharmaceutically equivalent

bioavailabilities (both rate and extent) after
administration in the same molar dose are
similar to such a degree that their effects
can be expected to be essentially the same
Hanoi, 2006-19-01
16
Therapeutic Equivalence

Therapeutic equivalence:
– Pharmaceutically equivalent
– Same safety and efficacy profiles after
administration of same dose:
bioequivalent

Interchangeability
Hanoi, 2006-19-01
17
Comparative
Pharmacodynamic Studies

Not recommended when:
– active ingredient is absorbed into the
systemic circulation
– pharmacokinetic study can be
conducted

Local action / no systemic absorption
Hanoi, 2006-19-01
18
Comparative Clinical Studies

Pharmacokinetic profile not possible

Lack of suitable pharmacodynamic
endpoint

Typically insensitive
Hanoi, 2006-19-01
19
Comparative in vitro Studies

May be suitable in lieu of in vivo
studies under certain circumstances

Requirements for waiver to be
discussed

Currently no “biowaiver” (waiving the
requirement for a bioequivalence
study) in prequalification project
except for additional strength
Hanoi, 2006-19-01
20
When are bioequivalence
studies employed?

Multisource product vs. Innovative
product

Pre-approval changes
– Bridging studies

Post-approval changes

Additional strengths of existing
product
Hanoi, 2006-19-01
21
Bioequivalence Studies:
Basic Design Considerations

Minimize variability not attributable to
formulations

Minimize bias

REMEMBER: goal is to compare
performance of the two products
Hanoi, 2006-19-01
22
“Gold Standard” Study
Design

Single-dose, two-period, crossover

Healthy volunteers

Subjects receive each formulation
once

Adequate washout
Hanoi, 2006-19-01
23
Multiple-dose Studies

More relevant clinically?

Less sensitive to formulation
differences
Hanoi, 2006-19-01
24
Multiple-dose Studies may be
employed when:

Drug is too potent/toxic for
administration in healthy volunteers
– Patients / no interruption of therapy

Extended/modified release products
– Accumulation using recommended
dosing interval
– In addition to single-dose studies
Hanoi, 2006-19-01
25
Multiple-dose Studies may be
employed when:

Non-linear pharmacokinetics at
steady-state (e.g., saturable
metabolism)

Assay not sufficiently sensitive for
single-dose study
Hanoi, 2006-19-01
26
Crossover vs. Parallel
Designs

Crossover design preferred
– Intra-subject comparison
– Lower variability
– Generally fewer subjects required

Parallel design may be useful
– Drug with very long half-life
– Crossover design not practical
Hanoi, 2006-19-01
27
Parallel Design
Considerations

Ensure adequate number of subjects

Adequate sample collection
– Completion of Gastrointestinal transit
/ absorption process
– 72 hours normally sufficient
Hanoi, 2006-19-01
28
Fasted vs. Fed Designs

Fasted study design preferred
– Minimize variability not attributable to
formulation
– Better able to detect formulation
differences
Hanoi, 2006-19-01
29
Fed Study Designs may be
employed when:

Significant gastrointestinal (GI)
disturbance caused by fasted
administration

Product labeling restricts
administration to fed state
Hanoi, 2006-19-01
30
Fed Study Design
Considerations

Fed conditions depend on local diet
and customs

Dependent on reason for fed design
– Avoiding GI disturbance
• Minimal meal to minimize impact
– Required due to drug substance /
dosage form
• Modified-release products
Hanoi, 2006-19-01
31
Fed Study Design
Considerations cont.
– Required due to drug substance /
dosage form
• Complicated pharmacokinetics
• Known effect of food on drug substance

Fed conditions designed to promote
maximal perturbation
– High fat
– High Calorie
– Warm
Hanoi, 2006-19-01
32
Replicate vs. non-replicate
designs

Standard approach
– Non-replicated
– Single administration of each product
– Average bioequivalence
Hanoi, 2006-19-01
33
Replicate Designs

Typically four-period design
– Each product administered twice

Intra-subject variability

Subject X formulation interaction

Different approaches possible
– Average bioequivalence
– Individual bioequivalence
Hanoi, 2006-19-01
34
Replicate Designs

Advantages
– More information available
– Different approaches to assessment
possible

Disadvantages
– Bigger commitment for volunteers
– More administrations to healthy
volunteers
– More expensive to conduct
Hanoi, 2006-19-01
35
Helpful Guidelines

FDA - Guidance for Industry: “Bioavailability and
Bioequivalence Studies for Orally Administered Drug
Products – General Considerations” (Oct. 2000)

Canadian Guidance for Industry: “Conduct and Analysis of
Bioavailability and Bioequivalence Studies – Part A: Oral
Dosage Formulations used for systemic effects.” (1992)

EU “Note for Guidance on the Investigation of
Bioavailability and Bioequivalence”
– CPMP/EWP/QWP/1401/98 and related guidances and documents
(www.emea.eu.int/pdfs/human/ewp )

Many other related guidances,
consider current scientific discussion
Hanoi, 2006-19-01
36
Discussion

Questions

Comments

Opinions
Hanoi, 2006-19-01
37