Switchgear Technical Data TD280016EN Effective July 2015 Supersedes R280-90-19 8/2012 COOPER POWER SERIES Communications Point Data Base for Communications Protocol 2179 For use with Eaton’s Cooper Power series Form 6 Recloser Control Form 6 Cooper 2179 Device Profile Data Dictionary Form 6 Cooper 2179 Map Points July 9, 2015 v3.0 THE INFORMATION CONTAINED IN THIS DOCUMENT IS THE PROPERTY OF EATON. UNAUTHORIZED REPRODUCTION OR MODIFICATION IS PROHIBITED. Document 1.00 1.01 1.02 1.03 2.00 3.00 2179 Point Sequence Range 2-Bit Status Simple Bit Status Pulse Accumulators Analog Inputs Special Calculations Control Output Date 5/8/2002 3/15/2004 7/26/2005 10/28/2005 8/24/2012 7/9/2015 Description Initial release. Added triple single basic scan and SBO definitions. Changed the Analog Scale Factor for the Instantaneous Power Factors to 10000. Minor edits in the Basic Scan, Status tab. Updates and re-release for ProView 5.0 Updates and re-release for ProView 5.1 Minimum 0 (0x0) 48 (0x30) 64 (0x40) 128 (0x80) 0 (0x0) 0 (0x0) Maximum 31 (0x1F) 63 (0x3F) 95 (0x5F) 255 (0xFF) 127 (0x7F) 255 (0xFF) Page 1 Cover Page Form 6 Cooper 2179 Device Profile Data Dictionary INPUT SUBSYSTEM Binary Input Status Description Recloser Closed Recloser Open Control is Locked Out Any Control or System Alarm Above Minimum Trip Supervisory Off Non-Reclosing Ground Trip Blocked SEF Blocked CLPU Blocked Fast Trips Blocked Profile Selected (Normal) Profile Selected (Alt1) Profile Selected (Alt2) Profile Selected (Alt3) Hot Line Tag Bus Voltage Present (Phase A) Bus Voltage Present (Phase B) Bus Voltage Present (Phase C) Reverse Power Flow Battery Test in Progress No AC Power Battery Alarm ci8:Alt1 (TB3:9-10) ci9:Alt2 (TB3:11-12) ci10:Alt3 (TB3:13-14) ci11:Nrml (TB3:15-16) co1:aux (TB1:11-12,13) co2:ok (TB1:14-15) co3:hlt (TB1:16-17) co4:gtb (TB1:18-19) ss1:lo (TB1:9-10) co5:nr (TB3:17-18) co6:alm (TB3:19-20,21) co7:nrm (TB4:1-2) co8:alt1 (TB4:3-4) co9:alt2 (TB4:5-6) co10:alt3 (TB4:7-8) Register Bit ID 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 2-Bit Status Sequence Simple Status Sequence 00 01 02 03 04 0 (0x0) 05 06 07 48(0x30) 08 09 10 11 12 1 (0x1) 13 14 15 00 01 02 03 04 2 (0x2) 05 06 07 49(0x31) 08 09 10 11 12 3 (0x3) 13 14 15 00 01 02 03 04 4 (0x4) 05 50(0x32) Page 2 Basic Scan, Status Form 6 Cooper 2179 Device Profile Data Dictionary INPUT SUBSYSTEM Binary Input Status Description co11:frq (TB4:9-10) co12:vlt (TB4:11-12,13) Reclose Retry Enabled A Phase Fault Trip B Phase Fault Trip C Phase Fault Trip Ground Fault Trip SEF Trip ci1:RTrip (TB1:3-4) ci2:SClose (TB1:5-6) ci3:STrip (TB1:7-8) ci4:GTB (TB3:1-2) ci5:NRecl (TB3:3-4) ci6:TargR (TB3:5-6) ci7 (TB3:7-8) Ground Overcurrent Alarm Phase Overcurrent Alarm Negative Sequence Overcurrent Alarm Hot Line Tag On from Configurable Logic Hot Line Tag On from Communications Hot Line Tag On from Front Panel Switch Control Circuit Interrupted USEF Blocked Profile Selected (Alt 4) Profile Selected (Alt 5) Not Used Register Bit ID 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 4 (0x4) 2-Bit Status Sequence Simple Status Sequence 06 07 50(0x32) 08 09 10 11 12 5 (0x5) 13 14 15 00 01 02 03 04 6 (0x6) 05 06 07 51(0x33) 08 09 10 11 12 7 (0x7) 13 14 15 Page 3 Basic Scan, Status Form 6 Cooper 2179 Device Profile Data Dictionary INPUT SUBSYSTEM Binary Input Status (Triple-Single) Description Recloser Closed (Phase A) Recloser Open (Phase A) Control is Locked Out (Phase A) Any Control or System Alarm Above Minimum Trip Supervisory Off Non-Reclosing Ground Trip Blocked SEF Blocked CLPU Blocked Fast Trips Blocked Profile Selected (Normal) Profile Selected (Alt1) Profile Selected (Alt2) Profile Selected (Alt3) Hot Line Tag Bus Voltage Present (Phase A) Bus Voltage Present (Phase B) Bus Voltage Present (Phase C) Reverse Power Flow Battery Test in Progress No AC Power Battery Alarm ci8:Alt1 (TB3:9-10) ci9:Alt2 (TB3:11-12) ci10:Alt3 (TB3:13-14) ci11:Nrml (TB3:15-16) co1:aux (TB1:11-12,13) co2:ok (TB1:14-15) co3:hlt (TB1:16-17) co4:gtb (TB1:18-19) ss1:lo (TB1:9-10) co5:nr (TB3:17-18) co6:alm (TB3:19-20,21) co7:nrm (TB4:1-2) co8:alt1 (TB4:3-4) co9:alt2 (TB4:5-6) co10:alt3 (TB4:7-8) Register Bit ID 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 2-Bit Status Sequence Simple Status Sequence 00 01 02 03 04 0 (0x0) 05 06 07 48(0x30) 08 09 10 11 12 1 (0x1) 13 14 15 00 01 02 03 04 2 (0x2) 05 06 07 49(0x31) 08 09 10 11 12 3 (0x3) 13 14 15 00 01 02 03 04 4 (0x4) 05 50(0x32) Page 4 Basic Scan, Status (TrplSingle) Form 6 Cooper 2179 Device Profile Data Dictionary INPUT SUBSYSTEM Binary Input Status (Triple-Single) Description co11:frq (TB4:9-10) co12:vlt (TB4:11-12,13) Reclose Retry Enabled A Phase Fault Trip B Phase Fault Trip C Phase Fault Trip Ground Fault Trip SEF Trip ci1:RTrip (TB1:3-4) ci2:SClose (TB1:5-6) ci3:STrip (TB1:7-8) ci4:GTB (TB3:1-2) ci5:NRecl (TB3:3-4) ci6:TargR (TB3:5-6) ci7 (TB3:7-8) Ground Overcurrent Alarm Phase A Overcurrent Alarm Negative Sequence Overcurrent Alarm Hot Line Tag On from Configurable Logic Hot Line Tag On from Communications Hot Line Tag On from Front Panel Switch Control Circuit Interrupted (Phase A) Recloser Closed (Phase B) Recloser Open (Phase B) Control is Locked Out (Phase B) Control Circuit Interrupted (Phase B) Recloser Closed (Phase C) Recloser Open (Phase C) Control is Locked Out (Phase C) Control Circuit Interrupted (Phase C) Phase B Overcurrent Alarm Phase C Overcurrent Alarm Ganged Mode 1-3 Mode 1-1 Mode USEF Blocked Profile Selected (Alt 4) Profile Selected (Alt 5) Not Used Register Bit ID 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 4 (0x4) 2-Bit Status Sequence Simple Status Sequence 06 07 50(0x32) 08 09 10 11 12 5 (0x5) 13 14 15 00 01 02 03 04 6 (0x6) 05 06 07 51(0x33) 08 09 10 11 12 7 (0x7) 13 14 15 00 01 02 03 04 8 (0x8) 05 06 07 52(0x34) 08 09 10 11 12 9 (0x9) Page 5 Basic Scan, Status (TrplSingle) Form 6 Cooper 2179 Device Profile Data Dictionary INPUT SUBSYSTEM 52(0x34) Binary Input Status (Triple-Single) Description Not Used Not Used Not Used Register Bit ID 77 78 79 2-Bit Status 9 (0x9) Sequence Simple Status Sequence 13 14 15 Page 6 Basic Scan, Status (TrplSingle) Form 6 Cooper 2179 Device Profile Data Dictionary INPUT SUBSYSTEM Counters Description Trip Counter (Phase A) Trip Counter (Phase B) Trip Counter (Phase C) Trip Counter (Ground) Trip Counter (SEF) Total Trip Counter Index Sequence 00 01 02 03 04 05 64 (0x40) 65 (0x41) 66 (0x42) 67 (0x43) 68 (0x44) 69 (0x45) Page 7 Basic Scan, Counters Form 6 Cooper 2179 Device Profile Data Dictionary INPUT SUBSYSTEM Counters (Triple-Single) Description Trip Counter (Phase A) Trip Counter (Phase B) Trip Counter (Phase C) Trip Counter (Ground) Trip Counter (SEF) Total Trip Counter Operations Counter (Phase A) Operations Counter (Phase B) Operations Counter (Phase C) Index Sequence 00 01 02 03 04 05 06 07 08 64 (0x40) 65 (0x41) 66 (0x42) 67 (0x43) 68 (0x44) 69 (0x45) 70 (0x46) 71 (0x47) 72 (0x48) Page 8 Basic Scan, Counters (TS) Form 6 Cooper 2179 Device Profile Data Dictionary INPUT SUBSYSTEM Analog Inputs Index Sequence Scale Factor 90% Full Scale Value (hardcoded to 29491) Zero-Reference Value (hardcoded to 0) 00 01 128 (0x80) 129 (0x81) 1 1 A Phase Primary Current Magnitude B Phase Primary Current Magnitude C Phase Primary Current Magnitude 3I0 Primary Current Magnitude 02 03 04 05 130 (0x82) 131 (0x83) 132 (0x84) 133 (0x85) 10 10 10 10 Amps Amps Amps Amps A Phase Primary Voltage Magnitude B Phase Primary Voltage Magnitude C Phase Primary Voltage Magnitude 06 07 08 134 (0x86) 135 (0x87) 136 (0x88) 1 1 1 Volts Volts Volts A Phase Power Factor B Phase Power Factor C Phase Power Factor 09 10 11 137 (0x89) 138 (0x8a) 139 (0x8b) 10000 10000 10000 A Phase Primary Apparent Power B Phase Primary Apparent Power C Phase Primary Apparent Power 12 13 14 140 (0x8c) 141 (0x8d) 142 (0x8e) 1 1 1 kVA kVA kVA A Phase Primary Real Power B Phase Primary Real Power C Phase Primary Real Power 15 16 17 143 (0x8f) 144 (0x90) 145 (0x91) 1 1 1 kW kW kW A Phase Primary Reactive Power B Phase Primary Reactive Power C Phase Primary Reactive Power 18 19 20 146 (0x92) 147 (0x93) 148 (0x94) 1 1 1 kvar kvar kvar Line Frequency 21 149 (0x95) 100 Hz A Phase Primary Demand Currents B Phase Primary Demand Currents C Phase Primary Demand Currents 22 23 24 150 (0x96) 151 (0x97) 152 (0x98) 10 10 10 Amps Amps Amps Battery Voltage Battery Current 25 26 153 (0x99) 154 (0x9a) 100 1000 Volts Amps Description Units Page 9 Basic Scan, Analogs Form 6 Cooper 2179 Device Profile Data Dictionary OUTPUT SUBSYSTEM Select-Before-Operate Points Description * Close Mechanism * Trip Mechanism Block Reclosing Block Ground Trip Block SEF Block CLPU Block Fast Trips * Profile - Normal * Profile - Alt1 * Profile - Alt2 * Profile - Alt3 * Reset Targets * Reset Demand Meters * Reset Alarms * Test Battery * Hot Line Tag Set * Hot Line Tag Reset Enable Reclose Retry Enable Sync Check Block USEF * Profile - Alt4 * Profile - Alt5 Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used * Momentary/Self Resetting Register Sequence 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 0 (0x0) 1 (0x1) 2 (0x2) 3 (0x3) 4 (0x4) 5 (0x5) 6 (0x6) 7 (0x7) 8 (0x8) 9 (0x9) 10 (0xA) 11 (0xB) 12 (0xC) 13 (0xD) 14 (0xE) 15 (0xF) 16 (0x10) 17 (0x11) 18 (0x12) 19 (0x13) 20 (0x14) 21 (0x15) 22 (0x16) 23 (0x17) 24 (0x18) 25 (0x19) 26 (0x1A 27 (0x1B) 28 (0x1C) 29 (0x1D) 30 (0x1E) 31 (0x1F) Conditioned by Supervisory State (Factory Default) Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Crosshatch Page 10 indicates point is supervised regardless of setting SBO Form 6 Cooper 2179 Device Profile Data Dictionary OUTPUT SUBSYSTEM Select-Before-Operate Points (Triple-Single) Description * Close Mechanism (Phase A) * Trip Mechanism (Phase A) Block Reclosing Block Ground Trip Block SEF Block CLPU Block Fast Trips * Profile - Normal * Profile - Alt1 * Profile - Alt2 * Profile - Alt3 * Reset Targets * Reset Demand Meters * Reset Alarms * Test Battery * Hot Line Tag Set * Hot Line Tag Reset Enable Reclose Retry Enable Sync Check * Trip Mechanism (Phase B) * Trip Mechanism (Phase C) * Close Mechanism (Phase B) * Close Mechanism (Phase C) * Activate Ganged Mode * Activate 1-3 Mode * Activate 1-1 Mode * Trip All Phases * Close All Phases Block USEF * Profile - Alt4 * Profile - Alt5 Not Used * Momentary/Self Resetting Register Sequence 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 0 (0x0) 1 (0x1) 2 (0x2) 3 (0x3) 4 (0x4) 5 (0x5) 6 (0x6) 7 (0x7) 8 (0x8) 9 (0x9) 10 (0xA) 11 (0xB) 12 (0xC) 13 (0xD) 14 (0xE) 15 (0xF) 16 (0x10) 17 (0x11) 18 (0x12) 19 (0x13) 20 (0x14) 21 (0x15) 22 (0x16) 23 (0x17) 24 (0x18) 25 (0x19) 26 (0x1A) 27 (0x1B) 28 (0x1C) 29 (0x1D) 30 (0x1E) 31 (0x1F) Conditioned by Supervisory State (Factory Default) Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Crosshatch Page 11 indicates point is supervised regardless of setting SBO (Triple-Single) Technical Data TD280016EN Communications Point Data Base Effective July 2015 Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton’s Cooper Power Systems Division 2300 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerseries © 2015 Eaton All Rights Reserved Printed in USA Publication No. TD280016EN July 2015 Eaton is a registered trademark. All other trademarks are property of their respective owners. For Eaton's Cooper Power series Form 6 recloser control information call 1-877-277-4636 or visit: www.eaton.com/cooperpowerseries.