Survey
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Product Selector Guide Transformer Protection – Selector Guide Features Device 345 P642 P652 • • • • • • • • • • 2 • • • 2 • • • 2 • • 15/1 • • 12/1 • G/N/P G/N/P • G/N/P G/N/P • Transformer Protection APPLICATIONS & FUNCTIONALITY Low to Medium size LV and MV Transformers Medium to Large size MV-HV Transformers Auto-transformers Non-Standard Transformers Two windings Three windings More then three windings 3-phase Voltage inputs PROTECTION & CONTROL Transformer Differential Maximum Number of Windings/Restraint Inputs Harmonic Restraint Internal Winding Standard Phase Shift Compensation Internal Winding Non-Standard Phase Shift Compensation Dynamic CT Ratio-Matching CT Mismatch Range Restricted Ground Fault - RGF/REF Over-excitation (Voltz Per Hertz) Phase Undervoltage IOC, Ground/Neutral/Phase TOC, Ground/Neutral/Phase Negative Phase Sequence Overcurrent Custom programmable overcurrent curves Overvoltage - Phase Overvoltage - Neutral Overvoltage - Auxiliary Overvoltage - Negative Sequence Current Directional, Neutral/Phase. Voltage Transformer Fuse Failure Current Transformer Supervision Under/Overfrequency Synchrocheck Synchrophasor Thermal Overload Power Swing Blocking Out of Step Backup Distance Protection Voltage Dependent Overcurrent (VCO/VRO) Transformer Hottest-spot Temperature Transformer Aging factor Transformer Loss of Life Lockout Tap Changer Monitoring Breaker Failure Arc Flash Detection 87T 87G 24 27P 50G/N/P 51G/N/P 46 59P 59N 59X 59_2 67 N/P VTFF/VTS CTS 81U/O 25 49 68 78 21 51V • 16/1 • G/N/P G/N/P • • • • 86 • • • • • • 50BF • • • 4 12 12 • • 2 6 6 • simple 32 64/32 • Trip 10 Trip 18 AUTOMATION Settings Groups Contact Inputs (max) Contact Outputs (max) Non-volatile latches Programmable Logic FlexElements™ Virtual Inputs/Outputs Direct Inputs/Outputs Programmable Pushbuttons Trip/Close Coil Supervision User-Programmable LEDs User-Programmable Self Test Selector Switch Digital Counters Digital Elements Transducer Analog Inputs/Outputs (max) RTD Inputs (max) 2 10 7 16 GEGridSolutions.com 4/4 10 Product Selector Guide Features Continued Device 345 P642 P652 • • • • • • • • MONITORING & METERING 5 • • • • • 256 32 512 24 512 16 • • • • • • (1) • • COMMUNICATIONS INTERFACES Front Port Local Access Rear Communications (RS232/RS422) Rear Communications (G.703, C37.94) Ethernet Fiber (Ports) PROTOCOLS Courier ModBus RTU DNP3 Serial EGD Protocol IEC61850 IEC 60870-5-104 IEC 60870-5-103 Simple Network Time Protocol TCP/IP HTTP PRP (IEC 62439-3 Clause 4) HSR (IEC 62439-3 Clause 5) IRIG-B Input Process Bus (IEC 61850-9-2) • • • • • • • For the most up-to-date selector guides, please visit GEGridSolutions.com/SelectorGuides GEGridSolutions.com • • • • • • • • • • • Transformer Protection Power Factor Current – RMS Current – Phasor Current – Demand Current - Unbalance Voltage Power - Apparent, Real, Reactive MW, MVA, Mvar Demand Breaker Arc Current Energy Frequency Temperature Current Harmonics (max) Loss of Life Calculations Fault Report User Programmable Trip Reports Event Recorder - Number of Events Oscillography/Transient Recorder - Sampling Rate Trip Counters Data Logger / Trend Recording Simulation Mode Product Selector Guide Transformer Protection – Selector Guide Features Device 745 845 P643 P645 T35 T60 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 3 • • • 3 • • • 3 • • • 5 • • • 6 • • • 6 • • • • • 16/1 • • • 20/1 • • • G/N/P G/N/P • • • • • • P/N • • 32/1 • 32/1 • • • G/N/P G/N/P Transformer Protection APPLICATIONS & FUNCTIONALITY Low to Medium size LV and MV Transformers Medium to Large size MV-HV Transformers Auto-transformers Non-Standard Transformers Two windings Three windings More then three windings 3-phase Voltage inputs PROTECTION & CONTROL Transformer Differential Maximum Number of Windings/Restraint Inputs Harmonic Restraint Internal Winding Standard Phase Shift Compensation Internal Winding Non-Standard Phase Shift Compensation Dynamic CT Ratio-Matching CT Mismatch Range Restricted Ground Fault - RGF/REF Over-excitation (Voltz Per Hertz) Phase Undervoltage IOC, Ground/Neutral/Phase TOC, Ground/Neutral/Phase Negative Phase Sequence Overcurrent Custom programmable overcurrent curves Overvoltage - Phase Overvoltage - Neutral Overvoltage - Auxiliary Overvoltage - Negative Sequence Current Directional, Neutral/Phase. Voltage Transformer Fuse Failure Current Transformer Supervision Under/Overfrequency Synchrocheck Synchrophasor Thermal Overload Power Swing Blocking Out of Step Backup Distance Protection Voltage Dependent Overcurrent (VCO/VRO) Transformer Hottest-spot Temperature Transformer Aging factor Transformer Loss of Life Lockout Tap Changer Monitoring Breaker Failure Arc Flash Detection 87T 87G 24 27P 50G/N/P 51G/N/P 46 59P 59N 59X 59_2 67 N/P VTFF/VTS CTS 81U/O 25 49 68 78 21 51V 86 50BF G/N/P G/N/P • • • • • • • • • • • • • • • 15/1 • • • G/N/P G/N/P • 15/1 • • • G/N/P G/N/P • • • • • • P/N • • • • P/N • • • • • • • • • • • • • • • • • • 6 14 10 • • 4 40 24 • • 4 40 24 • • 16/16 32/32 64/32 64/32 3 • 15 • • • • 4/7 12 10 Trip 18 10 Trip 18 4/4 10 4/4 10 • G/P • • • • • • • P/N • • • • • • • • • • • • • AUTOMATION Settings Groups Contact Inputs (max) Contact Outputs (max) Non-volatile latches Programmable Logic FlexElements™ Virtual Inputs/Outputs Direct Inputs/Outputs Programmable Pushbuttons Trip/Close Coil Supervision User-Programmable LEDs User-Programmable Self Test Selector Switch Digital Counters Digital Elements Transducer Analog Inputs/Outputs (max) RTD Inputs (max) 4 16 8 Trip 1 1 GEGridSolutions.com 6 96 64 • • • 64/96 32/32 12 Trip/Close 48 • • • • 24/12 24 6 96 64 • • • 64/96 32/32 12 Trip/Close 48 • • • • 24/12 24 Product Selector Guide Features Continued Device 745 845 P643 P645 T35 T60 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 512 24 512 24 MONITORING & METERING • • • • • • • 21 • • 40 12 • • • • • • • • 25 • • • 1024 128 • • • • • • • • 1024 64 • • 25 • • • 1024 64 • • • • • • •(3) • • • • •(3) • • • • • • • • • • • • • • • • • • • • • • • • COMMUNICATIONS INTERFACES Front Port Local Access Rear Communications (RS232/RS422) Rear Communications (G.703, C37.94) Ethernet Fiber (Ports) • • • • • • • • • •(2) • • • • • • • • • • • • • • • • • • • • • • • • PROTOCOLS Courier ModBus RTU DNP3 Serial EGD Protocol IEC61850 IEC 60870-5-104 IEC 60870-5-103 Simple Network Time Protocol TCP/IP HTTP PRP (IEC 62439-3 Clause 4) HSR (IEC 62439-3 Clause 5) IRIG-B Input Process Bus (IEC 61850-9-2) • • • • • • • • • For the most up-to-date selector guides, please visit GEGridSolutions.com/SelectorGuides GEGridSolutions.com • Transformer Protection Power Factor Current – RMS Current – Phasor Current – Demand Current - Unbalance Voltage Power - Apparent, Real, Reactive MW, MVA, Mvar Demand Breaker Arc Current Energy Frequency Temperature Current Harmonics (max) Loss of Life Calculations Fault Report User Programmable Trip Reports Event Recorder - Number of Events Oscillography/Transient Recorder - Sampling Rate Trip Counters Data Logger / Trend Recording Simulation Mode