Download PUB‐NLH‐498  Island Interconnected System Supply Issues and Power Outages  Page 1 of 2 Further to the response to CA‐NLH‐055, state whether or not the primary and 

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts
no text concepts found
Transcript
PUB‐NLH‐498 Island Interconnected System Supply Issues and Power Outages Page 1 of 2 1 Q. Further to the response to CA‐NLH‐055, state whether or not the primary and 2 secondary auxiliary power supplies can be impacted simultaneously by disturbances 3 on the ac transmission network and/or ac retail distribution network. 4 5 6 A. Primary and back‐up station auxiliary power supplies for each converter station are 7 listed in Hydro's response to CA‐NLH‐053. The simultaneous interruption of these 8 supplies would require a complete outage to the high‐voltage transmission system 9 at the site of the converter station. 10 11 As noted in Hydro's response to CA‐NLH‐053, each converter station is designed 12 with two ac station service supplies to provide power to the converter station 13 auxiliaries. The ac station service supplies are connected to the ac terminal station 14 (i.e., 230 kV bus) in a circuit breaker arrangement that ensures that a fault on one 15 ac station service transformer with a circuit breaker failure to open does not result 16 in the tripping of the second ac station service transformer. Further, connections 17 on the low voltage side (i.e., station service/auxiliary load side) of the ac station 18 service transformers is configured such that upon failure of one station service 19 transformer, circuit breakers can be opened and closed so that the remaining 20 station service transformer can supply all load. In addition, the protection and 21 control systems are redundant and supplied from redundant dc battery banks such 22 that loss of one protection and control scheme or battery bank does not result in a 23 trip to the converter station equipment. 24 25 With both ac station service supplies being connected to the same high voltage 26 transmission system, each station service supply will experience the same voltage 27 sags, dips and spikes that may occur on the connecting high voltage transmission 1 PUB‐NLH‐498 Island Interconnected System Supply Issues and Power Outages Page 2 of 2 system due to normal fault clearing. As noted in Hydro's response to CA‐NLH‐055, 2 the converter equipment is designed to ensure that the HVdc system can remain 3 online under abnormal voltage conditions caused by critical faults or other 4 contingencies. 5 6 Given that the redundant ac station service supplies are connected to the same 7 high voltage transmission system, simultaneous loss of both ac station service 8 supplies would require the loss of all high voltage transmission lines connecting the 9 ac component of the converter station to the interconnected transmission system. 10 In essence, there would have to be a complete outage to the ac component of the 11 converter station. The simultaneous loss of all ac transmission lines connecting the 12 converter station to the interconnected transmission system is a rare event. In the 13 case of the Soldiers Pond Converter Station, for example, this would be an N‐6 14 contingency. 15 16 Despite the extreme unlikelihood of the loss of all ac transmission lines to the 17 converter station, and subsequent loss of both ac station service supplies, each 18 converter station is equipped with back‐up diesel generation which is designed to 19 start following loss of ac supply from the grid and provide power to critical 20 equipment such as the valve cooling system, heating and ventilation, etc. to ensure 21 converter equipment is not damaged.