ΜΕΣΑ ΔΙΑΚΟΠΗΣ, ΠΡΟΣΤΑΣΙΑΣ ΚΑΙ ΕΛΕΓΧΟΥ ΚΥΚΛΩΜΑΤΩΝ ΟΙΚΙΑΚΩΝ
ΗΛΕΚΤΡΙΚΩΝ ΕΓΚΑΤΑΣΤΑΣΕΩΝ
ΣΤΟΧΟΣ:
Ο μαθητής να:
αναγνωρίζει και να επιλέγει τα κατάλληλα Μέσα Διακοπής, Προστασίας και
Ελέγχου κυκλωμάτων οικιακών ηλεκτρικών εγκαταστάσεων.
Main Switch - 2 Pole
Miniature Circuit Breaker (MCB)
6A 1pole 6kA
10A 1pole 6kA
16A 1pole 6kA
20A 1pole 6kA
25A 1pole 6kA
32A 1pole 6kA
40A 1pole 6kA
50A 1pole 6kA
63A 1pole 6kA
Residual Current Device (RCD)
2 Pole
16A / 10 mA
16A / 10 mA
40A / 30 mA
40A / 100 mA
63A / 30 mA
63A / 100 mA
RCBOs - B Type - Available in 7 Ratings
An RCBO is a combined RCCB and MCB in one unit
providing earth leakage, overload and short circuit
protection.
An RCBO may be installed anywhere along the length of
the busbar and will occupy one outgoing way.
Manufactured in accordance to BS EN 61009-1.
Available in the following ratings:
RCBO-6/30/SP - 6A (B Type) 30mA 1module RCBO
RCBO-10/30/SP - 10A (B Type) 30mA 1module RCBO
RCBO-16/30/SP - 16A (B Type) 30mA 1module RCBO
RCBO-20/30/SP - 20A (B Type) 30mA 1module RCBO
RCBO-32/30/SP - 32A (B Type) 30mA 1module RCBO
RCBO-40/30/SP - 40A (B Type) 30mA 1module RCBO
RCBO-50/30/SP - 50A (B Type) 30mA 1module RCBO
Switchfuse
32A 1P
63A 1P
DIN-rail Mounted Transformer
Transformers, Buzzers and Bells - Bell Transformers (230V/12V-8V)
6V bell transformer
8V bell transformer
12V bell transformer
Automatic Staircase Light, Time Delay Relay
Latching relays
Latching relays - operate when
impulsed by a signal voltage.
The impulse can be provided via
a pushbutton or pushswitch.
The first pulse operates the relay
and latches it to its set (opposite)
state, the next operation of the
pushbutton returns the relay to its
reset (original) state.
Installation Contactor (18mm)
- 230V AC contactor designed for domestic applications
and din rail mounting.
installation contactor, 230V 20A 2NO
installation contactor, 230V 20A 2NC
installation contactor, 230V 20A 1NC 1NO
10W Din Rail Power Supply 24Vdc 0.4A
Digital Time Switch - Daily or Weekly Programme - 1 output - 16A - 250V
Analogue Time Switch - Daily Programme - 16A - 250V
Main Switch – Moulded Case Circuit Breaker (MCCB) 3 Poles 8KA 63A 690V AC
Main Switch - 4 Pole Isolator
80A 30mA 4 Pole RCD
RCD (residual current device) sometimes
called RCCB (residual current circuit
breaker) or ELCB (earth leakage circuit
breaker).
They have 2 specific purposes:
-To protect plant and equipment from fires
started by low fault currents passing from
live to earth.
-To prevent fatal electric shock on
personnel by reducing to safe levels the
value and length of time a person is
exposed to current flow through the body.
An RCD does not detect over-current or
short circuits and should be used in
conjunction with a MCB.
Manufactured in accordance to BS EN
61008-1.
40A / 30 mA
40A / 100 mA
40A / 300 mA
63A / 30 mA
63A / 100 mA
63A / 300 mA
100A / 30 mA
100A / 100 mA
100A / 300 mA
RCBO (MCB combined rccb - rcbo)
Miniature Circuit Breaker (MCB)
6A 3pole 6kA
10A 3pole 6kA
16A 3pole 6kA
20A 3pole 6kA
25A 3pole 6kA
32A 3pole 6kA
40A 3pole 6kA
50A 3pole 6kA
63A 3pole 6kA
Switchfuse
32A 3P
63A 3P
Installation Contactor 24A (16kW) 230V
4 Pole (36mm)
- 230V AC contactor designed for
domestic applications and din rail
mounting.
- DC coil for silent operation. Suitable for
housing within a consumer unit or modular
enclosure.
- Manufactured in accordance with BS EN
60947-4-1