CC4 CC4 1 TELECOM COOLING CONTROLLER Dantherm Telecom Cooling Controller CC4 is designed for speed control and monitoring of up to three 48V DC operated fans, control of compressor, heater and damper. CC4 is suitable for control of Combo Cooling units, free cooling units and applications where total heat management is done by several existing climate units whom are supposed to work together and avoid conflicting start-stops. CC4 has inputs for several temperature sensors and monitoring devices. Temperature control strategy is configurable. Applications: Dantherm Flexibox Dantherm combo Cooling FEATURES AND BENEFITS Energy saving control strategy; with fans controlled with unique stable RPM independent of supply voltage fluctuations. Energy saving control strategy, by use of free cooling strategy / active cooling strategy. Wide Supply voltage range accommodating 40-60VDC Supports high power fans up to 10A output. (max two 10A fans) Configuration parameters stored in on-board non-volatile memory. Configurable digital input/outputs. The fan is step less controlled with stable RPM independent of supply voltage fluctuations – resulting in minimal power consumption and prolonged fan life time. Wide operating supply voltage: 40-60V DC complies with 48V DC telecom supply voltage range (both – and +). Supports high power fans - up to 10A for each fan output (max two 10A fans). Reverse polarity protection of controller. Inrush current limiter, which allows hot insert. Plug connection for alarms, remote temperature sensor and digital inputs for quick and reliable wire termination. Galvanic insulated alarm outputs. Insulation voltage is 500V. DC power plug with screw terminals, for easy and reliable installation. TTL Link serial connection to use with TTL/USB cable for Laptop. RS485 serial connection, with ModBus protocol. LED for on-site alarm- and operation status observation. Easy configuration of customized settings. New configuration to be loaded by SD card. LVD Low Voltage Disconnection – In case of low voltage supply – the fans will stop and thereby prolong backup time and battery life time. Emergency cooling in case of overheating results in 100% fan speed. Optional features SD card Remote temperature sensor Serial TTL/USB adapter.(Standard adapter for use with standard terminal PC software) Display. (Monitoring and parameter change) China Sweden tel: +86 512 6667 8500 e-mail: [email protected] tel: +46 121 130 40 e-mail: [email protected] Denmark USA tel: +45 96 14 37 00 e-mail: [email protected] tel: +1 864 595 9800 e-mail: [email protected] TECHNICAL DATA CC4 Version Dantherm Telecom Cooling Controller CC4 Item number DC supply voltage range 40-60 V For use with dry contact Digital 1,2,3,4,5 (10mA @ 12V) (1K pull up resistor to 12V) NTC -30 to 85°C (-22 to 185°F) Temperature sensor 1,2,3,4 NTC type NTCLE100E3272GB0 Output Fan 1, 2, 3 +, -, T, P (10A) Digital Damper int/ext. 0/48V DC 100mA Digital AC1 & AC2 Dry contact (500mA/60V) Digital AL1 & AL2 Dry contact (500mA/60V) Digital Heater, Compr, Cond. 0/48V DC 300mA Communication Opto-insolated TTL +, -, TX, RX Opto-insolated RS 485 A/B Memory Onboard EEprom 1M non volatile Mass storage device Up to 32 G SD Flash Environmental Temperature range -40 to 85°C (-40 to 185°F) Safety EN/UL 60950-1 EMC China Sweden EN 61000-6-2:2005 EN 61000-6-3:2007 tel: +86 512 6667 8500 e-mail: [email protected] tel: +46 121 130 40 e-mail: [email protected] 074620 Phoenix PC 4/ 2-G-7,62 20020039-C0x1B01LF - Terminal Blocks 20020039-C0x1B01LF - Terminal Blocks AMP Mini Universal MATE-N-LOK 20020039-C0x1B01LF - Terminal 20020039-C0x1B01LF - Terminal 20020039-C0x1B01LF - Terminal 20020039-C0x1B01LF - Terminal Blocks Blocks Blocks Blocks AMP - 281698-6 RJ45 w. shield Storage of operating parameters. For logging and change of parameters Electromagnetic compatibility (EMC) – Part 6-2: Generic standards - Immunity for industrial environments EMC Emission (EN 55022 version: 1998+A1:200 +A2:2003_ClassB) Electromagnetic compatibility (EMC) – Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments Denmark USA tel: +45 96 14 37 00 e-mail: [email protected] tel: +1 864 595 9800 e-mail: [email protected] FAN CONTROL STRATEGY Boosted Speed Extended High Speed High Speed xR3/xD3 xR2/xD2 Coolling Set Point Free Cooling and Speed Control Idle Speed xR1/xD1 Set Point Range xT0 xT1 Set Point Range xT2 xTs xT3 xT5 xT4 xT7 xT6 Temperature [°C] COOLING CONTROL STRATEGY Function Dampers Open Dampers Open Dampers Closed Dampers Close Free cooling mode Active cooling mode AC1 & AC2 Lead-lag COMP. HEATER ON ALL AVAILABLE A/C’s ON ON Emergency mode Re-circulation mode www.dantherm.com dT3 cT2 cT3 cT0 dT1 cT0 cT1 dTs dT2 cT1 dT0 OFF hT1 All parameters can be changed to comply with customer settings. xD4 hT0 Refer to configuration table for definition of parameters. Fan RPM/duty Shelter Temperature [°C]