Download DIM2 - Atkinson Electronics Inc

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Test probe wikipedia , lookup

Surge protector wikipedia , lookup

Flip-flop (electronics) wikipedia , lookup

Radio transmitter design wikipedia , lookup

CMOS wikipedia , lookup

Analog television wikipedia , lookup

Oscilloscope types wikipedia , lookup

Multimeter wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Cellular repeater wikipedia , lookup

Amplifier wikipedia , lookup

Integrating ADC wikipedia , lookup

Valve audio amplifier technical specification wikipedia , lookup

Oscilloscope wikipedia , lookup

Transistor–transistor logic wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Voltage regulator wikipedia , lookup

Oscilloscope history wikipedia , lookup

Power electronics wikipedia , lookup

Analog-to-digital converter wikipedia , lookup

Schmitt trigger wikipedia , lookup

Operational amplifier wikipedia , lookup

Valve RF amplifier wikipedia , lookup

High-frequency direction finding wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Rectiverter wikipedia , lookup

Opto-isolator wikipedia , lookup

Transcript
DIGITAL INDICATION METER - LCD
DIM2
FEATURES
v
v
v
v
DISCONTINUED
Easy to read numbers
On-board power supply
Field calibration adjustments
Compact size
APPLICATIONS
v
v
v
v
Temperature indication
Humidity indication
Percentage of operation display
Differential pressure indication
DESCRIPTION
The DIM2 is a three and one-half digit LCD (liquid crystal
display) panel meter. The DIM2 will display 000 to 1999
with the decimal available in any of the four possible
positions. The large LCD digits are easy to read. It has an
on-board power supply for stand alone sensor operation.
REPLACED BY DIM3
SPECIFICATIONS
SIZE:
2.3" W x 1.1" H x 1.25" D
MOUNTING:
Insertion - mount through
2.2"W x 1" H rectangular opening.
POWER:
+5V DC Standard
+15V DC Option
24V AC/DC option
INPUT SIGNALS:
0-5V DC, 0-10V DC, 0-15V DC,
4-20mA, non-isolated
AD590 sensor
RTD sensors (100,1k,2k,10kV)
Staefa sensors (all)
OPERATION
The display used on the DIM2 is the ACCULEX DP-652
LCD digital panel meter. A sub-board is attached to the
back of the meter that houses the power supply and input
scaling circuitry. Stand alone sensors can be powered from
the DIM2 supply by indicating the sensor type when
ordering. The meter is factory calibrated, however ZERO
and SPAN potentiometers are available for field
adjustments. Please see field calibration and adjustments
for instructions.
WIRING CONFIGURATION
INPUT IMPEDANCE: >1 meg ohms sensor inputs
200kV for voltage inputs
250V for 4-20mA input
DISPLAY:
Acculex part # DP-652
0.35" high 3½ digit LCD model.
OUTPUT:
3½ digit display
0.000 - 1.999 optional
00.00 - 19.99 optional
000.0 - 199.9 standard
0000 - 1999 optional
ADJUSTMENTS:
ZERO & SPAN 6 20%
ACCURACY:
0.1% with linear input signal.
AMBIENT TEMP:
0-508C
ATKINSON ELECTRONICS, INC.
14 West Vine Street
Distributed by:
Murray, UT 84107
Phone (801) 262-6400, 1-800-261-3602
Fax (801) 261-3796, E-MAIL: [email protected]
REV 9/97
DIGITAL INDICATION METER - LCD
ORDERING INFORMATION
DIM2
PHYSICAL CONFIGURATION
DIM2/XX/XXX/XXX/XXX-XXX
Display Output Range
Decimal Position Code
Input Option Code
Power Supply Option Code
INPUT OPTION CODES
1-5VDC
5VDC
10VDC
15VDC
mA-50
mA-249
20VPC
AD590
RTD 7
SCS 9
CUST
-
1-5V DC input signal
0-5V DC input signal
0-10V DC input signal
0-15V DC input signal
4-20mA input w/50V load
4-20mA input w/249V load
0-20V phase cut input signal
Analog Devices AD590 sensor
RTD sensor 7
Staefa sensors 9
Custom sensor T
PANEL CUTOUT DETAIL
7 (specify RTD type, and temp. coefficient when ordering).
9 (specify Staefa sensor type when ordering).
T(specify custom sensor signal and range when ordering).
DISPLAY POWER SUPPLY VOLTAGE
05
06
15
24
-
5V DC
6V DC
15V DC
24V AC/DC
TYPICAL APPLICATION
DISPLAY OUTPUT RANGES
DP0
DP1
DP2
DP3
DPX
000 - 1999
00.0 - 199.9
0.00 - 19.99
.000 - 1.999
Specify desired output range for voltage or
milliamp inputs. (XXX-XXX)
ORDERING CODE EXAMPLES
DIM2 / 05 / mA / DP1 / 000.0-100.0
DIM2 / 05 / 10VDC / DP2 / 00.00-19.99
DIM2 / 15 / RTD-1K / / 20.0-120.0
DIM2 / 24 / mA / DP2 / 00.00-19.99
DIM2 / 15 / AD590 / / 32.0-100.0
Call for other calibration ranges and versions.
If you have a different application or need, please call 1-800-261-3602, and discuss your needs with our Sales Engineers.
ATKINSON ELECTRONICS, INC.
14 West Vine Street
Distributed by:
Murray, UT 84107
Phone (801) 262-6400, 1-800-261-3602
Fax (801) 261-3796, E-MAIL: [email protected]
REV 9/97
APPLICATIONS AND INSTALLATION INSTRUCTIONS
DIM2
APPLICATION - 1 AD590 TEMPERATURE INDICATION
APPLICATION - 2 RTD-1K TEMPERATURE INDICATION
The DIM2 can be factory configured for an AD590 temperature
sensor. Both the AD590 and DIM2 are powered by a 15 to
24V DC supply. The AD590's current signal is converted to a
voltage by a 10kV .1% internal dropping resistor on the DIM2.
The DIM2 can be factory configured for an RTD-1K
temperature sensor, with an internal pull-up resistor referenced
to the 5 volt supply for stand alone operation. The DIM2 can
be configured for 5V, 15V or 24V DC power supply operation.
APPLICATION - 3 VOLTAGE SIGNAL INDICATION
APPLICATION - 4
The DIM2 can be factory configured for a variety of voltage
inputs. Standard input voltage signals are 1 to 5V DC, 0 to 5V
DC and 0 to 10V DC.
The DIM2 can be factory configured for 4 to 20mA input
signals with 50V, 100V, or 250V load resistance. The DIM-2
DDC controller are connected in series with transmitter.
4 to 20mA SIGNAL INDICATION
APPLICATION - 5 MULTIPLE SIGNAL INDICATION WITH DIM2 AND UNIVERSAL CHANNEL SELECTOR (UI8CH)
The DIM2 in conjunction with the UI8CH can display eight different temperature or voltage signals. The DIM2 is configured for the
lowest and highest display value to be indicated. The UI8CH is customized for the various input signals to provide signal scaling, pullup resistors for sensors, or load resistors for current signals. The UI8CH has ZERO and SPAN potentiometers for each channel for
field calibration.
Call for other calibration ranges and versions.
If you have a different application or need, please call 1-800-261-3602, and discuss your needs with our Sales Engineers.
ATKINSON ELECTRONICS, INC.
14 West Vine Street
Distributed by:
Murray, UT 84107
Phone (801) 262-6400, 1-800-261-3602
Fax (801) 261-3796, E-MAIL: [email protected]
REV 9/97
APPLICATIONS AND INSTALLATION INSTRUCTIONS
APPLICATION - 6
4 to 20mA SIGNAL INDICATION
The DIM2's input can be factory configured to accept the
voltage drop from the WA 511 controller’s 4 to 20mA input
internal load resistor (24.9V). The DIM2 power supply is
configured to accept 15V DC from the controller.
APPLICATION - 7
DIM2
4 to 20mA SIGNAL INDICATION
The DIM2's input can be factory configured to accept the
voltage drop from the WA 511 controller’s 4 to 20mA input
internal load resistor (24.9V). The DIM2 power supply is
configured to accept the same 24V AC as the controller.
Call for other calibration ranges and versions.
If you have a different application or need, please call 1-800-261-3602, and discuss your needs with our Sales Engineers.
ATKINSON ELECTRONICS, INC.
14 West Vine Street
Distributed by:
Murray, UT 84107
Phone (801) 262-6400, 1-800-261-3602
Fax (801) 261-3796, E-MAIL: [email protected]
REV 9/97
APPLICATIONS AND INSTALLATION INSTRUCTIONS
DIM2
APPLICATION - 1 AD590 TEMPERATURE INDICATION
APPLICATION - 2 RTD-1K TEMPERATURE INDICATION
The DIM2 can be factory configured for an AD590 temperature
sensor. Both the AD590 and DIM2 are powered by the SM2
Controller’s 5V DC supply. The AD590's current signal is
converted to a voltage by a 3.65kV 1% CRM2 dropping
resistor.
The DIM2 can be factory configured for an RTD-1K
temperature sensor. Both the RTD-1K and DIM2 are powered
by the SM2 Controller’s 5V DC supply. The CRM2 RTD-1K
range module provides the pull-up resistor and the SM2 input
bias.
APPLICATION - 3 T-30 TEMPERATURE INDICATION
APPLICATION - 4
The DIM2 can be factory configured for a T-30 and be
powered by the SM2 Controller’s 5V DC supply. The CRM2
SCS-31 range module provides the pull-up resistor and the
input bias for the universal input on the SM2 Controller.
The DIM2 can be factory configured for H-90 or FKE... Klimo
sensors and be powered by the SM2 Controller’s 5V DC
supply. The CRM2 SCS-33 range module provides the input
scaling for the universal input on the SM2 Controller.
APPLICATION - 5 VOLTAGE/mA SIGNAL INDICATION
APPLICATION - 6 FKA-.../ H2 SENSOR INDICATION
The DIM2 can be factory configured to accept most voltage or
current signals and be powered by the SM2 Controller’s 5V DC
supply. The CRM2 range module provides the input scaling
and mA load resistor for the universal input on the SM2
Controller.
The DIM2 can be factory configured for a FKA... sensors with
0-10V DC output signals, and be powered by the SM2
Controller’s 5V DC supply. The CRM2 VLT-10 range module
provides the voltage divider resistor to divide 0-10V down to 05V DC.
H-90 / FKE SENSOR INDICATION
Call for other calibration ranges and versions.
If you have a different application or need, please call 1-800-261-3602, and discuss your needs with our Sales Engineers.
ATKINSON ELECTRONICS, INC.
14 West Vine Street
Distributed by:
Murray, UT 84107
Phone (801) 262-6400, 1-800-261-3602
Fax (801) 261-3796, E-MAIL: [email protected]
REV 9/97
APPLICATIONS AND INSTALLATION INSTRUCTIONS
DIM2
APPLICATION - 7 MULTIPLE SIGNAL INDICATION WITH DIM2 AND UNIVERSAL CHANNEL SELECTOR (UI8CH)
The DIM2 in conjunction with the UI8CH can display eight different temperature or voltage signals. The DIM2 is configured for
the lowest and highest display value to be indicated. The UI8CH is customized for the various input signals to provide signal
scaling, pull-up resistors for sensors, or load resistors for current signals. The UI8CH has ZERO and SPAN potentiometers for
field calibration.
APPLICATION - 8 SINGLE POWER SUPPLY FOR STAND ALONE SENSOR INDICATION
The DIM2 can be configured for power supply voltages between 15V to 24V DC, allowing stand alone temperature sensors, 420mA transmitters, or other transmitter devices to be powered by one power source. The DIM2 can be configured to provide
a 5V reference voltage with pull-up resistor for the T-30 or other STAEFA sensors. The DIM2 also can be configured to provide
a load resistance for AD590 sensor operation.
Call for other calibration ranges and versions.
If you have a different application or need, please call 1-800-261-3602, and discuss your needs with our Sales Engineers.
ATKINSON ELECTRONICS, INC.
14 West Vine Street
Distributed by:
Murray, UT 84107
Phone (801) 262-6400, 1-800-261-3602
Fax (801) 261-3796, E-MAIL: [email protected]
REV 9/97