Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Integrated Controls MT250 Series Microturbine Heat Recovery Synchronous Generator Combustor 250 kW Continuous Onsite Electrical Power with Integrated Heat Recovery Key Features Dresser-Rand is a global distributor of and provides a service support network in the oil and gas market for Ingersoll Rand Energy Systems microturbine product line. • High system efficiency • Grid-parallel, dual-mode, or grid-isolated electrical generation • Closed transition to grid-isolated mode during grid outage • Low emissions exceed stringent environmental standards • Product design life of 80,000 hours with overhauls • Integrated, variable-output, waste-heat recovery unit available • Process-industry qualified, internal fuel gas-booster available For more information on the MT 250 series microturbine, visit us on the Internet at www.dresser-rand.com or contact the following Dresser-Rand location: CARB 2007 Certification Dresser-Rand • Ingersoll Rand’s MT250 is the first microturbine to be certified to meet the California Air Resource Board 2007 emissions standards for distributed generation technologies West8 Tower Suite 1000 10205 Westheimer Road Houston, TX 77042 USA Tel: +1 713-354-6100 Fax: +1 713-354-6110 email: [email protected] Rugged Turbine Engine • Back-to-back rotating components • Proven oil-lubricated bearings • All bearings located at cold end • Based on KG2 engine design Integrated Heat Recovery • • • • Controllable output level Reduces overall footprint No ducting Suitable for potable applications Patented Recuperator • Critical to high efficiency • Considered best in industry Patented Combustor • Dry low NOx • Easily meets stringent environmental regulations Synchronous Generator • Similar technology used by utilities to power the grid • Running backup capability available Electrical Performance* Sound Level Important Note: Always use approved vector artwork supplied in this EPS file. Never create, recreate, retype, or rebuild artwork. Characteristic Specification Electrical efficiency (±2) 30% LHV without fuel-gas booster 29% LHV with fuel-gas booster Nominal heat rate (HHV) 12,645 Btu/kWh without fuel-gas booster 13,080 Btu/kWh with fuel-gas booster Nominal heat rate (LHV) 11,380 Btu/kWh without fuel-gas booster 11,770 Btu/kWh with fuel-gas booster Electrical power (±15) 250 kW nominal @ 59°F without gas booster 242 kW nominal @ 59°F with gas booster 300 kW @ 0°F Characteristic Specification Voltage 480 VAC/400 VAC Standard 85 dB(A) @ 1m Frequency 60 Hz/50 Hz Type of service 3 phase, wye, 4 wire Grid-isolated regulation (steady state) ±0.50% nominal voltage ±0.50% nominal frequency Transient handling (linear loads) (recovery within 5 seconds) ±10% nominal voltage max ±5 Hz frequency max © 2006 Ingersoll-Rand Company Low sound option 77 dB(A) @ 1m 485 9 11 3 Ancillary Equipment Characteristic Dimensions (LxWxH) Generator breaking resistor 34 x 39 x 30 in 87 x 98 x 76 cm Weight (est.) 240 lb 109 kg * at ISO Conditions (59ºF @ sea level, 60% RH) unless otherwise noted Recuperator Turbine Engine MT250 Physical Specifications Minimum Clearance Requirements Characteristic Specification Vertical clearance 102 in (259 cm) no overhead obstruction Indoor unit Outdoor unit Horizontal front, rear and left side 48 in (122 cm) Horizontal right side 72 in (183 cm) A B C Weight (est.) Indoor unit (in) (cm) 85.4 216.9 132.0 335.4 89.7 227.8 12,000 lb 5,440 kg Outdoor unit (in) (cm) 90.0 228.7 147.8 375.5 160.1 406.6 12,000 lb 5,440 kg Heat Output Recoverable to Water* C Left side A Front Front B The Microturbine Engine Cycle * Btu/hour from Heat Recovery Unit (HRU) at ISO conditions, damper fully open, ±15% Heat Recovery* Characteristic Specification Engine exhaust temp w/o HRU** 468°F (242°C) Engine gas flow** 5.1 lbm/s (2.3 kg/s) Max water flow 100 gpm (379 m3/hr) Max inlet water pressure 125 psig (862 kPa) Max inlet water temp 180°F (82°C) Emissions at 100% load* * at ISO conditions (59ºF @ sea level, 60% RH) unless otherwise noted ** predicted -7 16 27 38 49 0.31 325 300 0.30 Efficiency 0.29 Power 250 0.28 0.27 225 0.26 200 175 0.33 0.32 350 275 0°F <5 ppmv @ 15% O2 CO <5 ppmv @ 15% O2 VOC <5 ppmv @ 15% O2 Fuel Requirements 4 20 40 60 80 Air-inlet ambient temperature 100 0.25 120 Efficiency %LHV (±2 pts) Power kWe (±15 kW) 375 Specification NOx * pipeline natural gas only Electrical Output -18°C Characteristic Characteristic Specification Input pressure 8˝ WC to 200 psig 2 kPa to 1379 kPa Heat content (std.) 350 to 2500 Btu/scf 13,000 to 93,000 kJ/m3 Min temperature 33°F (1°C) Max temp.with gas booster 115°F (46°C) without gas booster 150°F (66°C) Weatherproof Outdoor Enclosure Note - kWe is electrical output at terminals corrected for parasitics, but not including gas-booster power. Ambient Temperature Limits Characteristic Specification Indoor unit 35° to 115°F (2° to 46°C) Outdoor unit* -10° to 115°F (-23° to 46°C) * some configurations may require additional cold-weather options ©2006 Dresser-Rand. Printed in U.S.A. Generator Braking Resistor Form 2126 These microturbine products were developed with the assistance of the Gas Technology Institute (formerly Gas Research Institute), Southern California Gas Company and New York Gas Group. This document comprises a general overview of the products described herein. It is solely for informational purposes, does not represent a warranty or guarantee of the information contained herein and is not to be construed as an offer to sell or a solicitation to buy. Contact Dresser-Rand for detailed design and engineering information suitable to your specific applications. Dresser-Rand reserves the right to modify its products and related product information at any time without prior notice.