Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
To turn pages go to the bottom of page and left click with the mouse on the arrow or use the left and right arrow keys on the keyboard. Heaters Catalog Contents Kysor Heaters 1 KH-100 Heater KH-150 Heater KH-200 Heater KH-300 Heater KH-400 Heater KH-500 Heater KH-900 Heater HP-1000 Heater/Pressurizer 1 2 3 4 5 6 7 8 Aftermarket Sys. Requirements 9 System Matrix 10 SEA/Bergstrom Heaters 11 C-001 Classich C-002 Classic Electro C-003 Basic C-004 Sydney C-005 Pleda C-006 Geval C-007 Midi C-008 Nibiera C-009 Nebion C-010 Ninen C-011 Stua C-012 S Index 11 12 13 14 15 16 17 18 19 20 21 22 Contents JCB1 NH13 23 www.kysorclimatesystems.com I Heaters KH-100 Heater Floor Mount Features • • • • • • • • Applications How To Order: Kysor No. KH-100 Heater Heavy Duty Steel Construction Single Source or Auxiliary Heater 3-Speed Blower Switch Adjustable Water Valve Control Durable Single Wheel Plastic Blower Recirculating Air Filter (2) 4” Directional Shut-Off Louvers (2) 5/8” O.D. Tube Connections 3375071 • Over the Road Vehicles • Industrial Vehicles • Light Duty Off-Highway Equipment System Power Requirements 12 Volts D.C. Technical Specifications: English 10,400 BTU/h Metric 3.0 kW Performance: SAE J638 @ 18.2 LPM (4.8 GPM) Air Flow: 90 SCFM 153 SCMH Max. Power Required: 3.6 Amps @ 14 Volts D.C. Weight: 13 lbs 5.9 kg www.kysorclimatesystems.com 1 Heaters Heaters KH-150 Heater Floor Mount Kysor No. KH-150 Heater Control Switch Kit (Optional) 3380015 3475077 System Power Requirements 12 Volts D.C. Features • • • • • • • • • • Heavy Duty Steel Construction Compact Auxiliary Heater 2-Speed Motor Recirculating Air Filter (2) 5/8” O.D. Tube Connections • Over the Road Vehicles • Industrial Vehicles • Light Duty Off-Highway Equipment Technical Specifications: English Metric 13,000 BTU/h 3.8 kW Applications How To Order: Kysor No. KH-200 Heater KH-200 Heater Flush Mounting Kit Motor Guard Kit Control Switch Kit Heavy Duty Steel Construction Heavy Duty Auxiliary Heater 2-Speed Motor (2) Universal Mounting Brackets (2) 5/8” O.D. Tube Connections 3380016 3380017 3475033 3475034 3475035 • Over the Road Vehicles • Industrial Vehicles • Light Duty Off-Highway Equipment System Power Requirements 12 Volts D.C. 24 Volts D.C. (Optional) (Optional) (Optional) Technical Specifications: Performance: SAE J638 @ 18.2 LPM (4.8 GPM) Air Flow: 115 SCFM 195 SCMH Max. Power Required: 3.6 Amps @ 13.8 Volts D.C. Weight: 9.8 lbs 4.5 kg 2 Universal Mount Features Applications How To Order: KH-200 Heater English 18,360 BTU/h Metric 5.4 kW Performance: SAE J638 @ 18.2 LPM (4.8 GPM) Air Flow: 145 SCFM 246 SCMH Max. Power Required: 3 Amps @ 13.8 Volts D.C. 1.5 Amps @ 27.6 Volts D.C. Weight: 9 lbs 4.1 kg www.kysorclimatesystems.com www.kysorclimatesystems.com 3 Heaters Heaters KH-300 Heater Universal Mount Kysor No. KH-300 Heater KH-300 Heater Flush Mounting Kit Motor Guard Kit Control Switch Kit Features • • • • • • • • • • • • • 3380018 3380019 3475038 3475039 3475040 • • • • System Power Requirements 12 Volts D.C. 24 Volts D.C. (Optional) (Optional) (Optional) Heavy Duty Steel Construction Heavy Duty Auxiliary Heater (2) 2-Speed Motor (2) Universal Mounting Brackets (2) 5/8” O.D. Tube Connections Over the Road Vehicles Industrial Vehicles Heavy Duty Off-Highway Equipment Mining Vehicles Heavy Duty Steel Construction Single Source or Auxiliary Heater Can provide up to (4) Air Delivery Outlets Mixing Capabilities 3-Speed Resistor 4” Air Outlet Heavy Duty Steel Blower Wheel (2) 5/8” O.D. Tube Connections Applications How To Order: Kysor No. KH-400 Heater KH-400 Heater KH-400 (with Air Distribution Plenum 3375079 3375080 3375081 • • • • System Power Requirements 12 Volts D.C. 24 Volts D.C. 12 Volts D.C. Over the Road Vehicles Industrial Vehicles Standard Duty Off-Highway Equipment Mining Vehicles Technical Specifications: Technical Specifications: English 30,000 BTU/h English 43,200 BTU/h Metric 8.8 kW Metric 12.6 kW Performance: SAE J638 @ 18.2 LPM (4.8 GPM) Air Flow: 340 SCFM 578 SCMH Max. Power Required: 14 Amps @ 13.8 Volts D.C. 7 Amps @ 27.6 Volts D.C. Weight: 22 lbs 10 kg Performance: SAE J638 @ 18.2 LPM (4.8 GPM) Air Flow: 265 SCFM 450 SCMH Max. Power Required: 6 Amps @ 13.8 Volts D.C. 3 Amps @ 27.6 Volts D.C. Weight: 14 lbs 6.4 kg 4 Universal Mount Features Applications How To Order: KH-400 Heater www.kysorclimatesystems.com www.kysorclimatesystems.com 5 Heaters Heaters KH-500 Heater Universal Mount Kysor No. KH-500 Heater KH-500 Heater Features • Heavy Duty Steel Construction • Single Source or Auxiliary Heater • 3-Speed Resistor • Durable Double Wheel Plastic Blower • (4) 4” Front & (2) 4” Side Air Outlet Openings • (2) Knockouts in Cover for Optional Air Outlets • (2) 5/8” O.D. Tube Connections • • • • • • 3380020 3380021 • • • • System Power Requirements 12 Volts D.C. 24 Volts D.C. How To Order: Over the Road Vehicles Industrial Vehicles Standard Duty Off-Highway Equipment Mining Vehicles Technical Specifications: English 52,380 BTU/h Heavy Duty Steel Construction Auxiliary Heater 3-Speed Resistor Stylish Compact Round Design Shock Mounted Motor (2) 5/8” O.D. Tube Connections Applications Kysor No. Kysor No. System Power Side Blow Face Blow Requirements KH-900 Heater 3375083 3375085 12 Volts D.C. KH-900 Heater 3375084 3375086 24 Volts D.C. New Control Switch Kit (Old Style Heater) KH-900 Heater 3475028 3475028 12 Volts D.C. KH-900 Heater 3475029 3475029 24 Volts D.C. New Control Switch Kit* 3475059 • Over the Road Vehicles • Industrial Vehicles • Light Duty Off-Highway Equipment *To be used with KH-900 Heaters (Part No. 3375083, 3375085, 3375086 & 3375084 Metric 15.3 kW Performance: SAE J638 @ 18.2 LPM (4.8 GPM) Air Flow: 500 SCFM 850 SCMH Max. Power Required: 19 Amps @ 13.8 Volts D.C. 9 Amps @ 27.6 Volts D.C. Weight: 24 lbs 10.9 kg 6 Universal Mount Features Applications How To Order: KH-900 Heater Technical Specifications: English Metric 43,200 BTU/h 12.6 kW Performance: SAE J638 @ 18.2 LPM (4.8 GPM) Air Flow: 340 SCFM 578 SCMH Max. Power Required: 14 Amps @ 13.8 Volts D.C. 7 Amps @ 27.6 Volts D.C. Weight: 22 lbs 10 kg www.kysorclimatesystems.com www.kysorclimatesystems.com 7 Heater/Pressurizer Aftermarket System Requirements HP-1000 Heater/Pressurizer Universal Mount Features • • • • • • • • Kysor No. HP-1000 Heater/ Pressurizer HP-1000 Heater/ Pressurizer Unit Heavy Duty Steel Construction Heavy Duty Heater/Pressurizer Heavy Duty Steel Double Wheel Blower Variable Speed Blower Switch Adjustable Water Valve Fresh Air Filter Package with Quick Release Latches for Quick Serviceability (4) 4” Directional Louvers (2) 5/8” O.D. Tube Connections Applications How To Order: 3375051 System Power Requirements 12 Volts D.C. 3375052 24 Volts D.C. • • • • Compressor Compressor Mounting Kit Radiator Mounted Condenser or Remote Mounted Electrc Fan Condenser Condenser Installation Kit (Required for Radiator Mount Condenser Only) Install Kit (Heaters Electrical Wiring Kit) Over the Road Vehicles Industrial Vehicles Heavy Duty Off-Highway Equipment Mining Vehicles Hose Kit Receiver Drier Optional Controls Notes Heaters KH-100 • but N/A 2 KH-150 • but N/A 2 KH-200 • but N/A KH-300 • but N/A See Note 2 KH-400 • but N/A See Note 2 2 KH-500 • but N/A See Note 2 2 KH-900 Technical Specifications: English 44,000 BTU/h Aftermarket System Requirements Checklist 2 Note 5 See Note 2 • but N/A HP-1000 Note 7 See Note 2 2, 5 2, 7 2 • Indicates additional components required to complete installation. NOTES: 1 Some remote mount electric fan condensers include receiver drier. 2 Heater hose is required. 3 Hydraulic pump & control kits are available for some applications. 4 Optional fresh air filter kit is available. 5 Optional mounting kit, motor guard & control switch kit is available. 6 Optional bunk control available for auxiliary use only. 7 Optional control switch kit is available. Metric 12.9 kW Performance: SAE J638 @ 18.2 LPM (4.8 GPM) Air Flow: 410 SCFM 696 SCMH Max. Power Required: 14 Amps @ 12 Volts D.C. 7 Amps @ 24 Volts D.C. Weight: 56 lbs 25.4 kg Aftermarket System Requirements Checklist Fan Manufacturer Fan Type Operating Medium Method of Control Fan Override Kit ( R-12) Various Air Operated (On-Off) Air disengaged/spring engaged or air engaged/ spring disengaged Thermo pneumatic temperature switch senses engine coolant & controls air flow to fan clutch 3499002 Various Electro-Magnetic Electro-Magnetic (On-Off) Thermo electric temperature switch senses engine coolant & controls electro-magnetic fan clutch. 3499003 Fan Override Kit (R-134a) NOTES: 1 Minimum fan speed should handle condensing requirements. System must be protected with Kysor high-&-low pressure safety switches to disengage clutch in case of malfunction or warranty is void. 2 All Kysor air conditioning system with radiator-mounted condenser must be equipped with the high-&-low pressure switches specified or warranty is void. (For all Override Applications) 3 The fan or shutter override control kit used must be Kysor approved or warranty is void. (For all Override Applications) 8 www.kysorclimatesystems.com www.kysorclimatesystems.com 9 System Matrix SEA/Bergstrom Heaters C-001 Classich KYSOR SYSTEMS SERVICE COMPONENTS MODEL DESC. VOLTAGE KYSOR NUMBER PART NUMBER 3375071 791014 KH-100 HEATER 12 KH-150 HEATER 12 KH-200 HEATER KH-300 KH-400 KH-500 HEATER HEATER HEATER KH-900 HEATER HP-1000 HEATER PRESS. MODEL THERMOSTAT MOTORS HEATER 3375094 791015 3380015 1000258378 12 3375073 B936104 1075005 24 3375074 B936111 1075006 12 3380016 1000258379 1075005 24 3380017 1000258381 1075006 12 3375077 B936121 1075005 24 3375078 B936122 1075006 12 3380018 1000258382 1075005 24 3380019 1000258383 1075006 12 3375079 B936015 1099024 24 3375080 B936077 1075013 12 3375093 B936116 1075033 24 3375082 B936117 1075015 12 3380020 1000258346 AIR COND. CONDENSER 1099124 24 3380021 1000258348 12 - SIDE 3375083 B936055 3375085 B936213 24 - SIDE 3375084 B936229 24 - FACE 3375086 B936228 12 3375051 B936191 1099004 24 3375052 B936202 1099019 HEATER COIL EVAP. COIL CONDENSER COIL DRIER BLOWER AXIAL FAN RESISTOR FAN SWITCH Features EXPANSION VALVE • 16 mm Water Hoses • 12 Slots for SWF Switches, according to needs FAN: 1299015 FAN: 1275004 FAN: 1275004 2099016 BW: 1199021 1199028/029 N/A 12 - FACE FAN BLADE OR WHEEL Headliner Mount N/A 2075001 2099016 N/A 2075001 1075044 2075005 1075046 2075007 1075010 2099016 FAN: 1275002 1075017 How To Order: 2075001 2099016 BW: 1199028 BW: 1199029 2075001 1099055 Kysor No. Classich Heater HIGH PRESS. LOW PRESS. SWITCH SWITCH RELAY WATER VALVE KH-100 RECIRC. FILTER FRESH AIR FILTER MISCELLANEOUS SERVICE PARTS 3175008 KH-150 1799014 KH-200 1775001 KH-300 1775009 KH-400 1775002 Technical Specifications: Performance: Air Flow: Max. Power Required Weight: 1775008 KH-500 1775018 KH-900 1775003 HP-1000 1775004 10 A0CC50ES System Power Requirements 12 Volts D.C. 2475003 3475018 2575022 English Metric 20,473 BTU/h 6.0 kW 406 SCFM 690 SCMH 15.5 Amps @ 12 Volts D.C. 15.4 lbs 7.0 kg Applications • Agricultural Equipment • Earth Moving Equipment • Special Vehicles CONTROL ASSY. www.kysorclimatesystems.com www.kysorclimatesystems.com 11 SEA/Bergstrom Heaters SEA/Bergstrom Heaters C-002 Classic Electro Headliner Mount Features • 16 mm Water Hoses • 12 Slots for SWF Switches, according to needs • 16 mm Water Hoses • 3-Speed How To Order: Kysor No. A0CC53ES System Power Requirements 12 Volts D.C. 12 Variants Kysor No. Basic Heater A0CC85ES System Power Requirements 12 Volts D.C. Kysor No. N04400037/1 N04400037/3 Applications Technical Specifications: Performance: Air Flow: Weight: Headliner Mount Features How To Order: Classic Electro Heater C-003 Basic English 1,706 BTU/h 265 SCFM 12.3 lbs Metric 0.5 kW 450 SCMH 5.6 kg • Agricultural Equipment • Earth Moving Equipment • Special Vehicles www.kysorclimatesystems.com Applications Technical Specifications: Performance: Air Flow: Weight: English 1,7063 BTU/h 265 SCFM 12.3 lbs Description Conveyor with four Ø45 mm Air Louvers Conveyor with four Ø50 mm Air Louvers Metric 0.5 kW 450 SCMH 5.6 kg www.kysorclimatesystems.com • Agricultural Equipment • Earth Moving Equipment • Special Vehicles 13 SEA/Bergstrom Heaters SEA/Bergstrom Heaters C-004 Sydney Floor/Headliner Mount Features • 10 mm & 16 mm Water Hoses • 3-Speed • Available in 12 or 24 Voltages • 10 mm & 16 mm Water Hoses • Available in 12 or 24 Voltages Variants Sydney Heater Sydney Heater A0CC43ES A0CC44ES System Power Requirements 12 Volts D.C. 24 Volts D.C. Technical Specifications: Performance: Air Flow: Max. Power Required: Weight: 14 English Metric 12,966 BTU/h 3.8 kW 100 SCFM 170 SCMH 4 Amps @ 12 Volts D.C. 2.5 Amps @ 24 Volts D.C. 3.1 lbs 1.4 kg Backwall/Sidewall Mount Features How To Order: Kysor No. C-005 Pleda Kysor No. N04400073 N04400060 How To Order: Variants Description Conveyor with three Ø45 mm Air Louvers Conveyor with one Ø45 mm & one 90° Ø45 mm Air Louvers Pleda Heater Pleda Heater Applications Technical Specifications: • Agricultural Equipment • Earth Moving Equipment • Special Vehicles Kysor No. Performance: Air Flow: Max. Power Required: Weight: www.kysorclimatesystems.com A0CC20ES A0CC21ES System Power Requirements 12 Volts D.C. 24 Volts D.C. English Metric 12,966 BTU/h 3.8 kW 100 SCFM 170 SCMH 4.5 Amps @ 12 Volts D.C. 3 Amps @ 24 Volts D.C. 9.3 lbs 4.2 kg www.kysorclimatesystems.com Kysor No. N04400029 Description Conveyor with two round & one rectangular Air Louvers Applications • Agricultural Equipment • Earth Moving Equipment • Special Vehicles 15 SEA/Bergstrom Heaters SEA/Bergstrom Heaters C-006 Geval Floor/Headliner Mount Features • 16 mm Water Hoses • Available in 12 or 24 Voltages • 16 mm Water Hoses • 3-Speed • Available in 12 or 24 Voltages Variants Geval Heater Geval Heater Electrical System A0CC73ES A0CC74ES X04510010 System Power Requirements 12 Volts D.C. 24 Volts D.C. Kysor No. N04400002 N04400002/1 N04400002/2 Technical Specifications: Performance: Air Flow: Max. Power Required: Weight: 16 English Metric 24,226 BTU/h 7.1 kW 471 SCFM 800 SCMH 18 Amps @ 12 Volts D.C. 9.5 Amps @ 24 Volts D.C. 16.5 lbs 7.5 kg Floor Mount Features How To Order: Kysor No. C-007 Midi Description Conveyor with one Ø75 mm & two Ø60 mm Air Louvers Conveyor with four Ø50 mm Air Louvers Conveyor with three Ø45 mm Air Louvers Applications • Agricultural Equipment • Earth Moving Equipment • Special Vehicles How To Order: Kysor No. Midi Heater Midi Heater A0CC97ES A0CC98ES System Power Requirements 12 Volts D.C. 24 Volts D.C. Technical Specifications: Performance: Air Flow: Max. Power Required: Weight: www.kysorclimatesystems.com Variants English Metric 24,567 BTU/h 7.2 kW 283 SCFM 480 SCMH 12 Amps @ 12 Volts D.C. 7 Amps @ 24 Volts D.C. 8.8 lbs 4.0 kg www.kysorclimatesystems.com Kysor No. N04400003 N04400003/1 Description Conveyor with three Ø45 mm Air Louvers Conveyor with three Ø47 mm Air Louvers Applications • Agricultural Equipment • Earth Moving Equipment • Special Vehicles 17 SEA/Bergstrom Heaters SEA/Bergstrom Heaters C-008 Nibiera Sidewall Mount Features • Electrical Resistance • Available in 12 or 24 Voltages • Electrical Resistance • Available in 12 or 24 Voltages Variants Nibiera Heater Nibiera Heater Nibiera Heater Nibiera Heater System Power Requirements A0CC26ES 12/48 Volts D.C. A0CC26ES/1 24/48 Volts D.C. A0CC27ES 12/80 Volts D.C. A0CC27ES/1 24/80 Volts D.C. Technical Specifications: Performance: Air Flow: Max. Power Required: Weight: 18 English Metric 3,071 BTU/h 0.9 kW 100 SCFM 170 SCMH 4 Amps @ 12 Volts D.C. 2.5 Amps @ 24 Volts D.C. 6.2 lbs 2.8 kg Sidewall Mount Features How To Order: Kysor No. C-009 Nebion Kysor No. N04400029 N04400070/1 Description Conveyor with three Ø63 mm Air Louvers Conveyor with two Ø39 mm Air Louvers Applications • Agricultural Equipment • Earth Moving Equipment • Special Vehicles How To Order: Kysor No. Nebion Heater Nebion Heater Nebion Heater Nebion Heater System Power Requirements A0CC28ES 12/48 Volts D.C. A0CC28ES/1 24/48 Volts D.C. A0CC29ES 12/80 Volts D.C. A0CC29ES/1 24/80 Volts D.C. Technical Specifications: Performance: Air Flow: Max. Power Required: Weight: www.kysorclimatesystems.com Variants English Metric 3,071 BTU/h 0.9 kW 100 SCFM 170 SCMH 4 Amps @ 12 Volts D.C. 2.5 Amps @ 24 Volts D.C. 6.2 lbs 2.8 kg www.kysorclimatesystems.com Kysor No. N04400029 N04400070/1 Description Conveyor with three Ø63 mm Air Louvers Conveyor with two Ø39 mm Air Louvers Applications • Agricultural Equipment • Earth Moving Equipment • Special Vehicles 19 SEA/Bergstrom Heaters SEA/Bergstrom Heaters C-010 Ninen Backwall/Sidewall Mount Features • Electrical Resistance • Available in 12 or 24 Voltages • 16 mm Water Hoses • Available in 12 or 24 Voltages Variants Ninen Heater Ninen Heater Ninen Heater Ninen Heater System Power Requirements A0CC24ES 12/48 Volts D.C. A0CC24ES/1 24/48 Volts D.C. A0CC25ES 12/80 Volts D.C. A0CC25ES/1 24/80 Volts D.C. Technical Specifications: Performance: Air Flow: Max. Power Required: Weight: 20 English Metric 3,071 BTU/h 0.9 kW 100 SCFM 170 SCMH 4 Amps @ 12 Volts D.C. 2.5 Amps @ 24 Volts D.C. 9.3 lbs 4.2 kg Sidewall Mount Features How To Order: Kysor No. C-011 Stua Kysor No. N04400029 How To Order: Description Conveyor with two round & one rectangular Air Louvers Stua Heater Stua Heater Applications Technical Specifications: • Agricultural Equipment • Earth Moving Equipment • Special Vehicles Kysor No. Air Flow: Max. Power Required: Weight: www.kysorclimatesystems.com A0CC32ES A0CC33ES System Power Requirements 12 Volts D.C. 24 Volts D.C. English Metric 235 SCFM 400 SCMH 10 Amps @ 12 Volts D.C. 6 Amps @ 24 Volts D.C. 9.3 lbs 4.2 kg www.kysorclimatesystems.com Applications • Agricultural Equipment • Earth Moving Equipment • Special Vehicles 21 SEA/Bergstrom Heaters C-012 S Index Backwall/Sidewall Mount Features • 16 mm Water Hoses • 3-Speed • Available in 12 or 24 Voltages How To Order: Kysor No. System Power Requirements S Heater A0CC03ES 12 Volts D.C. S Heater A0CC04ES 24 Volts D.C. 10 mm Rubber Fitting P02150006 22 Applications • • • • Agricultural Equipment Earth Moving Equipment Special Vehicles Forklifts www.kysorclimatesystems.com 3375051 3375052 3375071 3375079 3375080 3375081 3375083 3375084 3375085 3375086 3380015 3380016 3380017 3380018 3380019 3380020 3380021 3475028 3475029 3475033 3475034 3475035 3475038 3475039 3475040 3475059 3475077 3499002 3499003 A0CC03ES A0CC04ES A0CC20ES A0CC21ES A0CC24ES A0CC24ES/1 A0CC25ES A0CC25ES/1 A0CC26ES A0CC26ES/1 A0CC27ES A0CC27ES/1 A0CC28ES A0CC28ES/1 A0CC29ES 8 8 1 5 5 5 7 7 7 7 2 3 3 4 4 6 6 7 7 3 3 3 4 4 4 7 2 9 9 22 22 15 15 20 20 20 20 18 18 18 18 19 19 19 www.kysorclimatesystems.com Contents JCB1 A0CC29ES/1 A0CC32ES A0CC33ES A0CC43ES A0CC44ES A0CC50ES A0CC53ES A0CC73ES A0CC74ES A0CC85ES A0CC97ES A0CC98ES N04400002 N04400002/1 N04400002/2 N04400003 N04400003/1 N04400029 N04400037/1 N04400037/3 N04400060 N04400070/1 N04400073 P02150006 X04510010 19 21 21 14 14 11 12 16 16 13 17 17 16 16 16 17 17 15, 18, 19, 20 13 13 14 18, 19 14 22 16 NH13 23 ©2013 All material in this literature is as accurate as known at time of publication, but is subject to change without notice.