Download SH24C-177 - Potter Electric Signal Company, LLC

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Flip-flop (electronics) wikipedia , lookup

Flexible electronics wikipedia , lookup

Ohm's law wikipedia , lookup

Integrated circuit wikipedia , lookup

Multimeter wikipedia , lookup

Integrating ADC wikipedia , lookup

Index of electronics articles wikipedia , lookup

Power MOSFET wikipedia , lookup

Amplifier wikipedia , lookup

Oscilloscope history wikipedia , lookup

Regenerative circuit wikipedia , lookup

Analog television wikipedia , lookup

Analog-to-digital converter wikipedia , lookup

Radio transmitter design wikipedia , lookup

CMOS wikipedia , lookup

Voltage regulator wikipedia , lookup

Power electronics wikipedia , lookup

Surge protector wikipedia , lookup

Transistor–transistor logic wikipedia , lookup

Operational amplifier wikipedia , lookup

Valve audio amplifier technical specification wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Schmitt trigger wikipedia , lookup

Current mirror wikipedia , lookup

Electronic tuner wikipedia , lookup

Valve RF amplifier wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Network analysis (electrical circuits) wikipedia , lookup

Rectiverter wikipedia , lookup

Opto-isolator wikipedia , lookup

Transcript
SH24C-177
SELECT-A-STROBE/HORN®
• Meets or exceeds NFPA/ANSI Standards and ADA Accessability Guidelines
• UL Listed for ceiling and wall mounting
• Screw terminal capacity up to AWG #12
• Designed for use in sleeping and non-sleeping areas
• 24V strobe model with 177 candela intensity
• Horn field selectable tones:
3000 Hz interrupted or electro-mechanical
Temporal or non-temporal
High or low dBA output
• Mounts to 4” square, single gang, double gang, or octagonal back box; SPC-1 (retrofit plate) and RBX-1 (back box skirt) are optional
• Polarized strobes with wide operating voltage range using filtered DC or unfiltered FWR input voltage
• Synchronization requires SMD10-3A Sync module
• Available in red or white housing
The SH24C-177 Strobe/Horn features a 177 candela intensity output.
The horn provides two different field selectable tones and a high/low
setting that can be achieved with the use of mini-jumpers located on
the back of the unit. These appliances are polarized for connecting
to supervised fire alarm circuits. The strobe is designed with a xenon
flash tube and provides a candela intensity field selector switch
located on the front for maximum performance.
The SH24C-177 can be synchronized by using the SMD10-3A
Sync Module (daisy chain) to comply with NFPA recommendations
concerning photosensitive epilepsy when installing more than two
appliances within the field of view. The strobe signals are listed for indoor
use, wall mount, under UL 1971 Standard and are ADA compliant.
Engineering Specifications
The audible and visual alarm indicating appliances shall be Amseco
model SH24C-177 or equivalent device. The strobe shall be listed
under UL 1971 Standard for signaling devices for the hearing
impaired and shall be approved for fire protective service. The candela
output shall be field 177cd intensity output. The signaling strobe
shall operate on 24V DC from a non-coded, regulated DC supply or
full-wave rectified, unfiltered supply. The horn may operate on a 24V
DC coded system. The strobe/horn shall be designed to produce one
signal flash per second with continuously applied minimum voltage.
The strobe/horn may have a SPC-1 universal back mounting plate,
capable of ceiling and wall mounting to a back box. When strobe
synchronization is required, the strobe/horn shall be compatible with
the Potter SMD10-3A (daisy chain) or other source of sync protocol.
Audible and visual signaling devices shall be installed in sleeping
areas in accordance with current NFPA guidelines.
Dimensions: inches (mm)
2 25/32 (70)
STROBE HORN
+ - + -
3 3/8 (85.7)
Strobes must be used only on circuits with continuously operating
voltage. DO NOT use strobe on coded or interrupted circuits in
which the applied voltage is interrupted ON and OFF as the strobe
may fail to flash. The applied voltage must be within its rated input
voltage range. Fuse ratings on signaling circuits must handle peak
currents from all devices connected to those circuits.
6 7/8 (174)
1 13/32 (35)
Side View
Front View
3 3/8 (85.7)
Back View
Ordering Information
Model Number
Stock
Number
Housing
Color
Input
Voltage
Operating
Voltage
Range
Selectable
Strobe
Output (cd)
Horn
Sound
Ouput
Flash
Rate
Mounting
Type
Operating
Temperature
Range
SH24C-177R
4570001
Red
SH24C-177W
4570002
White
Regulated
24V DC/
FWR
16-33 VDC
16-33 VFWR
177
Selectable
60 times/
min.
Ceiling
and Wall
32°F - 120°F
(0°C - 49°C)
Potter Electric Signal Co., LLC • St. Louis, MO • Cust Service: 866-240-1870 • Tech Support:866-956-1211• Canada 888-882-1833 • www.pottersignal.com
PRINTED IN USA
MKT. #8850021 - REV E
7/10
PAGE 1 OF 3
SH24C-177
SELECT-A-STROBE/HORN®
Wiring Diagram
Wiring 1
Wiring 2
Refer to Fig. 1
Signal Operates Independently
FI
Strobe Signal
Circuit
Horn Signal
Circuit
FIRE
FI
F.A.C.P.
FI
E
To Next
Device or
End-of-Line
Resistor
E
E
To Next
Device or
End-of-Line
Resistor
Signal Circuit
R
F.A.C.P.
R
F.A.C.P.
R
R
FI
E
STROBE
HORN
To Next
Device or
End-of-Line
Resistor
FIRE
Wiring 3
Wiring Diagram for Audible Strobe Class “B” Circuit with Audible Silence Feature (SH24C)
SYNC MODULE SMD10-3A
H
H
INPUT
R
OUTPUT
To Next
Device or
End-of-Line
Resistor
FI
E
FI
Horn Signal
Circuit
Refer to Fig. 2
Fig. 1
STROBE
FIRE
F.A.C.P.
E
Strobe Signal
Circuit
R
F.A.C.P.
HORN
IN
OUT
IN
OUT
IN
OUT
IN
OUT
Wiring 4
Wiring Diagram for Audible Strobe Class “B” Circuit without Audible Silence Feature
FI
Refer to Fig. 2
FIRE
H
Fig. 2
FI
E
E
Signal Circuit
R
SYNC MODULE SMD10-3A
INPUT
OUTPUT
R
F.A.C.P.
H
To Next
Device or
End-of-Line
Resistor
STROBE
HORN
IN
OUT
IN
OUT
Factory setting jumper wire
Specifications
PRINTED IN USA
NonTemporal
Temporal
NonTemporal
Temporal
Horn Only
Horn and Strobe
Current Draw Table
PC3: Pattern
PC2: Tone
PC3: Volume
Max. RMS Operating
Current (mA)
Min. Sound Output
(dBA @ 10ft per UL 464)
PC3
PC2
PC1
Regulated
24V DC
(Typical)
Regulated
24V FWR
(Typical)
Regulated 24V DC
Electro
Mechanical
HIGH
1
1
1
419 (278)
511 (389)
86
LOW
1
1
0
402 (266)
497 (374)
76
3000 Hz
HIGH
1
0
1
419 (278)
511 (389)
87
LOW
1
0
0
402 (266)
497 (374)
77
Electro
Mechanical
HIGH
0
1
1
419 (278)
511 (389)
80
LOW
0
1
0
402 (266)
497 (374)
73
3000 Hz
HIGH
0
0
1
419 (278)
511 (389)
82
LOW
0
0
0
402 (266)
497 (374)
74
Electro
Mechanical
HIGH
1
1
1
49 (30)
45 (40)
86
LOW
1
1
0
34 (18)
34 (25)
76
3000 Hz
HIGH
1
0
1
49 (30)
45 (40)
87
LOW
0
1
0
34 (18)
34 (25)
77
Electro
Mechanical
HIGH
0
1
1
49 (30)
45 (40)
80
LOW
0
1
0
34 (18)
34 (25)
73
3000 Hz
HIGH
0
0
1
49 (30)
45 (40)
82
LOW
0
0
0
34 (18)
34 (25)
74
MKT. #8850021 - REV E
7/10
PAGE 2 OF 3
SH24C-177
SELECT-A-STROBE/HORN®
Sound Output
Dispersion (dB)
177cd
0
177.00
5-25
159.30
30-45
132.75
50
97.35
55
79.65
60
70.80
65-70
61.95
75-80
53.10
85-90
44.25
Compound 45
42.45
Horizontal
Vertical
+90
-2
-5
+60
0
-2
+30
1
-1
0
0
0
-30
-2
-1
-60
-3
-2
-90
-6
-5
Strobe Light
Only
Tone
Selection
PC3
Pattern
Jumper
Ceiling Mount
DEGREES
DEGREES
UL Required Minimum
Light Output
PC2
Tone
PC1
Volume
NonElectroTemporal Mechanical
High
Temporal
Low
3000Hz
Max. RMS operating Current (mA)
Regulated 24V DC
177cd
359 (typical 278)
Regulated
24V FWR
PC3 PC2 PC1
452 (typical 389)
Back of SH24C
Optional Mounting (using SPC-1 retrofit plate)
Single Gang
Back Box
4“ Square
Back Box
SPC-1
Retrofit
Plate
Double Gang
Back Box
SPC-1
Octagon
Back Box
SPC-1
Optional Surface Mounting (using RBX-1 back box skirt and SPC-1 retrofit plate)
Double Gang
Back Box
Single Gang
Back Box
4“ Square
Back Box
RBX-1
Back
Box Skirt
PRINTED IN USA
SPC-1
RBX-1
Octagon
Back Box
SPC-1
RBX-1
MKT. #8850021 - REV E
7/10
SPC-1
RBX-1
PAGE 3 OF 3