E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X9P Unit features Safety features ` Positive-guided relay outputs: – 7 safety contacts (N/O), instantaneous – 2 auxiliary contacts (N/C), instantaneous ` 2 semiconductor outputs ` Connection options for: – E-STOP pushbutton – Safety gate limit switch – Light barriers – Reset button ` LED indicator for: – Switch status channel 1/2 – Input circuits – Supply voltage – Reset circuit ` Semiconductor outputs signal: – Switch status channel 1/2 – Supply voltage is present ` Plug-in connection terminals (either spring-loaded terminal or screw terminal) ` See order reference for unit types Gertemerkmale Gertebild Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices ][Bildunterschrift_NOT_Sch.tuer_Licht Approvals PNOZ X9P The relay meets the following safety requirements: ` The circuit is redundant with built-in self-monitoring. ` The safety function remains effective in the case of a component failure. ` The correct opening and closing of the safety function relays is tested automatically in each on-off cycle. ` The unit has an electronic fuse. ][Sicherheitseigenschaften Schaltgerät_allgemeiner Teil Sicherheitseigenschaften Zusatz - Sicherung DC_PNOZ Unit description The safety relay meets the requirements of EN 60947-5-1, EN 60204-1 and VDE 0113-1 and may be used in applications with ` E-STOP pushbuttons ` Safety gates ` Light beam devices Bestimmung/Gertebeschreibung NOT-AUS, Schutzt, Lichtschr_PNOZ Order no. 777607 is without approval Zulassungen Block diagram il tb a h s k c lo B d A1 (B1) A2 (B2) S11 S12 S21 S22 = (~)* = Input Input S52 S33 S34 S37 Input Reset/ Start 13 23 33 43 53 63 73 81 91 K1 K2 Power Feedback 24 V/ 0 V 12 V K3 Y1 Y2 Y30 Y31 Y32 Y35 14 24 34 44 54 64 74 82 92 *Only applies when UB = 100 - 240 VAC Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected] NSG-D-2-169-2009-09 E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X9P Function description ` Single-channel operation: no redundancy in the input circuit, earth faults in the reset and input circuit are detected. ` Dual-channel operation without detection of shorts across contacts: redundant input circuit, detects – earth faults in the reset and input circuit, – short circuits in the input circuit and, with a monitored reset, in the reset circuit too. ][Funktionen_einkanalig ][Funktionen_zweikanalig_ohne_quer ` Dual-channel operation with detection of shorts across contacts: redundant input circuit, detects – earth faults in the reset and input circuit, – short circuits in the input circuit and, with a monitored reset, in the reset circuit too, – shorts between contacts in the input circuit. ` Automatic start: Unit is active once the input circuit has been closed. ][Funktionen_autoStart ][Funktionen_manuStart ` Manual reset: Unit is active once the input circuit is closed and then the reset circuit is closed. ` Monitored reset: Unit is active once – the input circuit is closed and then the reset circuit is closed and opened again. – the reset circuit is closed and then opened again once the input circuit is closed. ` Increase in the number of available instantaneous safety contacts by connecting contact expansion modules or external contactors. ][Funktionen_berStart_allg ][Funktionen_Kontaktvervielfachung ][Funktionen_zweikanalig_mit_quer_ber Timing diagram H C N U R s x 1 b n o u _ rm g a itd e ][Z 1 2 a b 3 a b POWER Reset/Start Input Output safe Output aux. Out semi RUN Out semi CH t1 t2 t1 t1 t2 t2 t1 t2 t1 t1 t2 t2 t3 Key ` Power: Supply voltage ` Reset/Start: Reset circuit S33-S34 ` Input: Input circuits S11-S12, S21S22, S52 ` Output safe: Safety contacts 13-14, 23-24, 33-34, 43-44, 53-54, 63-64, 73-74 ` Output aux: Auxiliary contacts 8182, 91-92 ` Out semi RUN: Semiconductor output supply voltage Y35 ` Out semi CH: Semiconductor output switch status Y32 ` c: Automatic reset ` d: Manual reset ` e: Monitored reset ` a: Input circuit closes before reset circuit ` b: Reset circuit closes before input circuit ` t1: Switch-on delay ` t2: Delay-on de-energisation ` t3: Recovery time ` Calculation of the max. cabling runs lmax in the input circuit: ` Sufficient fuse protection must be provided on all output contacts with capacitive and inductive loads. Wiring Please note: ` Information given in the “Technical details” must be followed. ` Outputs 13-14, 23-24, 33-34, 4344, 53-54, 63-64, 73-74 are safety contacts, outputs 81-82, 91-92 are auxiliary contacts (e.g. for display). ` To prevent contact welding, a fuse should be connected before the output contacts (see technical details). ][Verdrahtung_Si_Hi_unverz Imax = Rlmax Rl / km Rlmax = max. overall cable resistance (see technical details) Rl /km = cable resistance/km ` Use copper wire that can withstand 60/75 °C. Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected] NSG-D-2-169-2009-09 -2 E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X9P Preparing for operation Betriebsbereitschaft herstellen ` Supply voltage Supply voltage AC DC UB = 12 VDC/24 VDC/100 – 240 VAC A1 A2 L1 N B1 L+ PE B2 L- A1 L+ A2 L- UB = 12 VDC/24 VDC ` Input circuit Input circuit E-STOP without detection of shorts across contacts Single-channel Dual-channel S11 S1 S11 S21 S12 S21 S22 S52 S22 E-STOP with detection of shorts across contacts S12 S52 S11 Safety gate without detection of shorts across contacts S11 S11 S21 S52 S22 S12 S1 S11 S21 S12 S22 S21 S52 S22 S1 S1 S1 S2 S12 S52 Safety gate with detection of shorts across contacts S11 S11 S12 S52 S21 S1 S2 S22 Light beam device with detection of shorts across contacts via ESPE 24 V DC S21 S22 Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected] S12 S52 GND NSG-D-2-169-2009-09 E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X9P ` Reset circuit Reset circuit E-STOP/safety gate wiring (single-channel and dual-channel without shorts across contacts) Automatic reset E-STOP/safety gate wiring (dual-channel with shorts across contacts) S33 S12 S34 S34 Manual reset S3 S3 S33 S12 S34 S34 Monitored reset S3 S3 S33 S34 S12 S34 Y1 Y1 S37 S37 ` Feedback circuit Feedback circuit Contacts from external contactors Y1 Y2 13 (23 ... 73) 14 (24 ... 74) K5 K6 K5 L1 N K6 ` Semiconductor output Y31 24 V DC/12 V DC Y32 Y35 Y30 SPS Input SPS Input 0V ` Key S1/S2 S3 E-STOP/safety gate switch Reset button Switch operated Gate open Gate closed Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected] NSG-D-2-169-2009-09 -4 E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X9P Terminal configuration UB = 12 VDC/24 VDC Klemmenbelegung S11 S12 S12 S21 S22 Y1 Y2 A1 S33 S34 P3 S33 81 81 91 P4 PNOZ X9P P5 81 81 91 13 23 33 43 53 63 73 START POWER 13 23 33 43 53 63 73 IN - CH. 1 - OUT IN - CH. 2 - OUT 82 82 92 14 24 34 44 54 64 74 A2 P4 Y1 S37 82 82 92 P3 Y30 Y31 Y32 Y35 P5 14 24 34 44 54 64 74 S11 S52 UB = 24 VDC/100 -240 VAC S11 S12 S12 S21 S22 Y1 Y2 P3 A1 B1 S33 S34 S33 81 81 91 P4 PNOZ X9P AC POWER 13 23 33 43 53 63 73 P5 81 81 91 13 23 33 43 53 63 73 START IN - CH. 1 - OUT IN - CH. 2 - OUT 20162 82 82 92 14 24 34 44 54 64 74 A2 B2 P4 Y1 S37 82 82 92 P3 Y30 Y31 Y32 Y35 ` The safety relay should be installed in a control cabinet with a protection type of at least IP54. ` Use the notch on the rear of the unit to attach it to a DIN rail. ` Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing element (e.g. retaining bracket or an end angle). Montage_PNOZ_X S11 S52 Dimensions * with spring-loaded terminals Abmessungen 121 (4.76") Installation P5 14 24 34 44 54 64 74 94 (3.70") * 101 (3.98") Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected] 90 (3.54") NSG-D-2-169-2009-09 E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X9P Notice This data sheet is only intended for use during configuration. For installation and operation, please refer to the operating instructions supplied with the unit. Service life graph v rk u a d s n b e L D GB F E I NL Nennbetriebstrom (A) Nominal operating current (A) Courant coupé (A) Corriente nominal de servicio (A) Corrente di esercizio nominale (A) Nominale bedrijfsstroom (A) ][WICHTIG_PDB_alt 10 AC1: 230 V DC1: 24 V DC13: 24 V 1 AC1: 400 V AC15: 230 V 0.1 10 100 D Schaltspielzahl x 103 GB Cycles x 103 F Nombre de manuvres x 103 1000 10000 E Número de ciclos x 103 I Numero dei cicli di commutazione x 103 NL Aantal schakelingen x 103 ][Technische Daten PNOZ Technical details Electrical data Supply voltage Supply voltage UB AC Supply voltage UB DC Voltage tolerance Power consumption at UB AC Power consumption at UB DC Frequency range AC Residual ripple DC Voltage and current at Input circuit DC: 12.0 V Order no.: 777607 24.0 V Order no.: 777606, 777609, 787606, 787609 Reset circuit DC: 12.0 V Order no.: 777607 24.0 V Order no.: 777606, 777609, 787606, 787609 Feedback loop DC: 12.0 V Order no.: 777607 24.0 V Order no.: 777606, 777609, 787606, 787609 Number of output contacts Safety contacts (S) instantaneous: Auxiliary contacts (N/C): Utilisation category in accordance with EN 60947-4-1 Safety contacts: AC1 at 240 V Safety contacts: DC1 at 24 V Auxiliary contacts: AC1 at 240 V Auxiliary contacts: DC1 at 24 V Utilisation category in accordance with EN 60947-5-1 Safety contacts: AC15 at 230 V Safety contacts: DC13 at 24 V (6 cycles/min) Auxiliary contacts: AC15 at 230 V Auxiliary contacts: DC13 at 24 V (6 cycles/min) Contact material 100 - 240 V 12 V, 24 V -15 %/+10 % Order no.: 777606, 777609, 787606, 787609 -20 %/+20 % Order no.: 777607 8.5 VA Order no.: 777606, 787606 5.5 W Order no.: 777606, 777609, 787606, 787609 7.0 W Order no.: 777607 50 - 60 Hz 160 % 130.0 mA Order no.: 777607 50.0 mA Order no.: 777606, 777609, 787606, 787609 100.0 mA Order no.: 777606, 777609, 787606, 787609 200.0 mA Order no.: 777607 100.0 mA Order no.: 777606, 777609, 787606, 787609 200.0 mA Order no.: 777607 7 2 Imin: 0.01 A , Imax: 8.0 A Pmax: 2000 VA Imin: 0.01 A , Imax: 8.0 A Pmax: 200 W Imin: 0.01 A , Imax: 8.0 A Pmax: 2000 VA Imin: 0.01 A , Imax: 8.0 A Pmax: 200 W Imax: 5.0 A Imax: 7.0 A Imax: 5.0 A Imax: 7.0 A AgSnO2 + 0.2 µm Au Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected] NSG-D-2-169-2009-09 -6 E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X9P Electrical data External contact fuse protection (IK = 1 kA) to EN 60947-5-1 Blow-out fuse, quick Safety contacts: Auxiliary contacts: Blow-out fuse, slow Safety contacts: Auxiliary contacts: Circuit breaker 24 VAC/DC, characteristic B/C Safety contacts: Auxiliary contacts: Semiconductor outputs (short circuit proof) External supply voltage Voltage tolerance Max. overall cable resistance Rlmax input circuits, reset circuits single-channel at UB DC single-channel at UB AC dual-channel without detect. of shorts across contacts at UB DC dual-channel without detect. of shorts across contacts at UB AC dual-channel with detect. of shorts across contacts at UB DC dual-channel with detect. of shorts across contacts at UB AC Safety-related characteristic data PL in accordance with EN ISO 13849-1 Category in accordance with EN 954-1 SIL CL in accordance with EN IEC 62061 PFH in accordance with EN IEC 62061 SIL in accordance with IEC 61511 PFD in accordance with IEC 61511 tM in years Times Switch-on delay with automatic reset typ. with automatic reset max. with automatic reset after power on typ. with automatic reset after power on max. with manual reset typ. with manual reset max. on monitored reset with falling edge typ. on monitored reset with falling edge max. 10 A 10 A 6A 6A 6A 6A 12.0 V Order no.: 777607 24.0 V Order no.: 777606, 777609, 787606, 787609 DC,20 mA 12.0 V Order no.: 777607 24.0 V Order no.: 777606, 777609, 787606, 787609 DC -20 %/+20 % 45 Ohm Order no.: 777606, 777609, 787606, 787609 8 Ohm Order no.: 777607 45 Ohm Order no.: 777606, 787606 15 Ohm Order no.: 777607 90 Ohm Order no.: 777606, 777609, 787606, 787609 90 Ohm Order no.: 777606, 787606 15 Ohm Order no.: 777606, 777609, 787606, 787609 8 Ohm Order no.: 777607 15 Ohm Order no.: 777606, 787606 PL e (Cat. 4) Cat. 4 SIL CL 3 2.31E-09 SIL 3 2.03E-06 20 130 ms Order no.: 777607 200 ms Order no.: 777606, 777609, 787606, 787609 200 ms Order no.: 777607 250 ms Order no.: 777606, 777609, 787606, 787609 150 ms Order no.: 777607 220 ms Order no.: 777606, 777609, 787606, 787609 220 ms Order no.: 777607 300 ms Order no.: 777606, 777609, 787606, 787609 150 ms Order no.: 777607 200 ms Order no.: 777606, 777609, 787606, 787609 200 ms Order no.: 777607 250 ms Order no.: 777606, 777609, 787606, 787609 100 ms Order no.: 777607 150 ms Order no.: 777606, 777609, 787606, 787609 150 ms Order no.: 777607 220 ms Order no.: 777606, 777609, 787606, 787609 Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected] NSG-D-2-169-2009-09 E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X9P Times Delay-on de-energisation with E-STOP typ. with E-STOP max. with power failure typ. with power failure max. with power failure typ. UB AC: 100 V, 100 V with power failure max. UB AC: 100 V, 100 V with power failure typ. UB AC : 240 V with power failure max. UB AC : 240 V Recovery time at max. switching frequency 1/s after E-STOP after power failure after power failure on universal power supply Min. start pulse duration with a monitored reset with falling edge Simultaneity, channel 1 and 2 Supply interruption before de-energisation Environmental data EMC Vibration to EN 60068-2-6 Frequency Amplitude Climatic suitability Airgap creepage in accordance with EN 60947-1 Pollution degree Overvoltage category Rated insulation voltage Rated impulse withstand voltage Ambient temperature Storage temperature Protection type Mounting (e.g. cabinet) Housing Terminals Mechanical data Housing material Housing Front Cross section of external conductors with screw terminals 1 core flexible 2 core, same cross section, flexible: with crimp connectors, without insulating sleeve without crimp connectors or with TWIN crimp connectors Torque setting with screw terminals Cross section of external conductors with spring-loaded terminals: Flexible with/without crimp connectors Spring-loaded terminals: Terminal points per connection Stripping length 20 ms 30 ms 170 ms Order no.: 777606, 777609, 787606, 787609 60 ms Order no.: 777607 250 ms Order no.: 777606, 777609, 787606, 787609 80 ms Order no.: 777607 165 ms Order no.: 777606, 787606 200 ms Order no.: 777606, 787606 320 ms Order no.: 777606, 787606 450 ms Order no.: 777606, 787606 50 ms 100 ms Order no.: 777607 300 ms Order no.: 777606, 777609, 787606, 787609 500 ms Order no.: 777606, 787606 30 ms Order no.: 777607 50 ms Order no.: 777606, 777609, 787606, 787609 150 ms Order no.: 777606, 777609, 787606, 787609 50 ms Order no.: 777607 20 ms EN 60947-5-1, EN 61000-6-2 10 - 55 Hz 0.35 mm EN 60068-2-78 2 III 250 V 4.0 kV -10 - 55 °C -40 - 85 °C IP54 IP40 IP20 PPO UL 94 V0 ABS UL 94 V0 0.25 - 2.50 mm² , 24 - 12 AWG Order no.: 777606, 777607, 777609 0.25 - 1.00 mm² , 24 - 16 AWG Order no.: 777606, 777607, 777609 0.20 - 1.50 mm² , 24 - 16 AWG Order no.: 777606, 777607, 777609 0.50 Nm Order no.: 777606, 777607, 777609 0.20 - 1.50 mm² , 24 - 16 AWG Order no.: 787606, 787609 2 Order no.: 787606, 787609 8 mm Order no.: 787606, 787609 Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected] NSG-D-2-169-2009-09 -8 E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X9P Mechanical data Dimensions Height 101.0 mm Order no.: 787606, 787609 94.0 mm Order no.: 777606, 777607, 777609 90.0 mm 121.0 mm 570 g Order no.: 787609 575 g Order no.: 787606 580 g Order no.: 777607, 777609 585 g Order no.: 777606 Width Depth Weight Technische Daten_Satz Normen The standards current on 2006-06 apply. ][Dauerstrom_ACDC Conventional thermal current Number of contacts 1 2 3 4 5 6 7 Ith (A) at UB DC 8.00 A 8.00 A 8.00 A 7.00 A 6.00 A 5.50 A 5.00 A Ith (A) at UB AC 8.00 A Order no.: 777606, 787606 8.00 A Order no.: 777606, 787606 8.00 A Order no.: 777606, 787606 7.00 A Order no.: 777606, 787606 6.00 A Order no.: 777606, 787606 5.50 A Order no.: 777606, 787606 5.00 A Order no.: 777606, 787606 Bestelldaten Order reference Type PNOZ X9P C PNOZ X9P PNOZ X9P C PNOZ X9P PNOZ X9P Features 110 - 240 VAC 110 - 240 VAC 24 VDC 24 VDC 24 VDC 24 VDC 12 VDC Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected] Terminals Spring-loaded terminals Screw terminals Spring-loaded terminals Screw terminals Screw terminals Order no. 787 606 777 606 787 609 777 609 777 607 NSG-D-2-169-2009-09