Transcript
80 PLUS Verification and Testing Report
92.55%
91.40%
YES
TYPICAL EFFICIENCY (50% Load):
AVERAGE EFFICIENCY :
80 PLUS COMPLIANT:
4524
In Win Development Inc.
C 900W
N/A
2016
ATX12V,ESP12V,PS2
1/15/16
Rated Specifications
Value
Units
Input Voltage
Input Current
Input Frequency
Rated Output Power
100-240
6-10
50-60
900
Volts
Amps
Hz
Watts
200
8
150
6
100
4
50
2
0
0
-50 0
0.003
PF
0.95
0.98
0.99
1.00
ITHD (%) Load (%)
13.31%
10.75%
4.79%
4.31%
10%
20%
50%
100%
Input
Watts
0.012
0.015
-2
-4
-150
-6
-200
-8
Time (s)
Voltage
Current
Input AC Current Waveform (ITHD = 4.79%, 50% Load)
DC Terminal Voltage (V)/ DC Load Current (A)
-12V
3.3V
12V (cumulative of 12V1, 12V2, etc.)
12.37/6.62
12.06/0.03 3.36/1.06
12.31/13.3
12.06/0.05 3.36/2.13
12.24/33.19
12.07/0.13 3.34/5.32
12.16/66.12
12.08/0.27 3.31/10.63
105.57
202.13
496.10
1008.50
0.009
-100
Note: All measurements were taken with input voltage at 115 V nominal at 60 Hz.
IRMS A
A
0.96
1.79
4.34
8.80
0.006
Current (A)
Input Current and Voltage Waveforms
Voltage (V)
Ecos ID #
Manufacturer
Model Number
Serial Number
Year
Type
Test Date
Input and Output Power
5V
5Vsb
5.13/1.06
5.12/2.12
5.09/5.28
5.05/10.57
5.05/0.27
5.03/0.53
4.99/1.33
4.93/2.65
Output
Watts
92.58
185.04
459.15
908.75
Efficiency
%
87.70%
91.54%
92.55%
90.11%
Efficiency of the Power Supply
1200
100%
90%
80%
800
Efficiency (%)
Power (Watts)
1000
Input Watts
600
400
200
Output Watts
70%
60%
50%
40%
30%
20%
10%
20%
Efficiency %
0%
0
50%
Loading (% of Rated Output Power)
100%
0%
25%
50%
75%
100%
Loading (% of Rated Output Power)
These tests were conducted by a third party independent testing firm on behalf of the
80 PLUS Program. 80 PLUS is a certification program to promote highly-efficient power
supplies (greater than 80% efficiency in the active mode) in technology applications.
http://www.80plus.org/
125%