750kW Containerized Diesel Generator Set Model Emissions EGC-750DD EPA Certified Standby Rating Prime Rating 60 Hertz 750kW (937.5kVA) 600kW (750kVA) 750 KW (Shown with 40 ft. container optional ISO trailer chassis) Standard Features Detroit Diesel Heavy Duty Diesel Engine 4-cycle design, turbocharged, aftercooled, direct injection Polymide blade cooling fan Engine coolant heater Meets EPA emissions standards for mobile off-highway Fuel System 1000 gallon, single wall fuel tank Fuel priming system Fuel/water separators and drip pan Electric fuel pump External fuel fill 30 micron Racor® fuel filter system Alternator Brushless, 4-pole, synchronous, WYE connection Class H insulation system conforms to NEMA MG1-22, BS5000, CSA-C22-2, IEC-34-1 standards for temperature rise Drip-proof, self-venting, amortisseur windings Epoxy impregnated windings with tropical insulation for increased environmental protection and long life Electronic Voltage Regulator ■ Electronic automatic voltage regulator provides precise regulation ■ Separate three-phase excitation for fast recovery from block loads and motor starting Full Load Acceptance Accepts 100% of standby nameplate rating in one step, in compliance with NFPA, para 5-13.2.6 Generator Control Panel InteligenTM vibration-isolated controller Manual or remote engine start/stop RS232/Modbus communication support Safety shutdowns Externally mounted emergency stop switch Generator mainline circuit breaker, 100% rated electronically operated, UL listed Specially Designed Container ■ 40 ft. ISO container, sound-attenuated, foam-lined for extremely quiet operation ■ Isolated operator control room Solidly mounted battery rack and cooling system Intregral vibration isolators Exterior polyurethane coating system provides long life in extreme operating conditions Interior DC lights and timer switch Critical grade silencer with heat blankets Electrically operated roof mounted air intake vent doors Warranty Engine-generator sets are covered by an express written, one-year limited warranty 750kW Containerized Diesel Generator Set APPLICATION DATA Alternator Specifications Make Type Number of Leads Generator Type Voltage Regulator Insulation Material Temperature Rise Bearing: Number, Type Coupling Amortisseur Windings Voltage Regulation (no load to full load) One Step Load Acceptance % of rating per NFPA-110 Peak Motor Starting HP Generator Efficiency at Full Load Phase Sequence L-L Harmonic Max Total L-L Harmonic Max Single Voltage Dip Upon Full Load Application (1 Step) Voltage Rise Upon Full Load Rejection (1 Step) Marathon Magna Max 4-Pole, Rotating Field 10 or 12 Rotating Field; PMG Solid State, Digital, Model DVR2000 NEMA MG1-1.66 Class H Standby Rating: 125o C Prime Rating: 105o C Single, Sealed Flexible Disk Full 2% Maximum 100 500 95% ABC (L1, L2, L3) 5.0% 3.0% 20% for 1.6 sec. 10% for 0.6 sec. Engine Specifications Manufacturer/Model Detroit Diesel/MTU 12V2000-G81 4-cycle, Turbocharged, Type Air to Water Aftercooled Cylinder Arrangement V-12 Displacement 1458 in3 (23.9 liter) Bore 5.12 in. (130 mm) Stroke 5.91 in. (150 mm) Compression Ratio 14.5:1 Piston Speed (60Hz) 29.5 ft./sec. (9.0 m/sec) Bearing Main Number/Type 7, Replaceable, Precision Cylinder Block Cast iron Cylinder Head Material Cast iron Crankshaft Material Forged steel Valves Dual, Poppet Type Brake Mean Effective Pressure (BMEP) 338 psi (2330 kPa) Rated RPM (60 Hz) 1800 RPM Max. Power At Rated RPM (with fan) 1120 hp (835.2 kW) Governor Type Electronic Frequency Regulation: No load to full load Isochronous Frequency Regulation: Steady State +0.25 Hz Air Cleaner Type - All Models Dry, Dual Element The 750 KW Sound Attenuated Generator includes a reconnectable 10 or 12 lead generator that is configured for standard 60 Hz, 480V or 208V output. Special voltage outputs are available. Alternator Features ■ All ratings tested per MIL-STD-705 as applicable. ■ Generator protection for overload and short circuit. ■ Generator is designed and built within NEMA, IEEE and ANSI standards for temperature rise. ■ PMG exciter for superior regulation and response. ■ Three phase sensing on regulator with EMI protection. ■ Skewed rotor for smooth voltage wave form. ■ Vacuum impregnated epoxy varnish - Fungus resistant per MIL-I-24092. ■ Sustain short circuit current at 300% of rated current up to 10 seconds. Amperage Voltage Phase 120/208 277/480 3 3 Power Factor 0.8 0.8 Continuous Amperes Standby Prime 2602 2082 1128 902 Engine Electrical System Battery Charging Alternator Ground Type Volts Ampere Rating Starter Motor Rated Voltage Minimum Recommended Battery for 0 °C / Cold Cranking Performance Negative 24 VDC 70A 24 VDC 700 CCA Exhaust System Exhaust Temperature at Rated kW (Dry Exhaust) Exhaust Flow at Rated kW Silencer Type Maximum Allowable Backpressure Exhaust Outlet Size at hook-up 915 oF (491 oC) 6370 cfm (180.4 m3/min) Critical 40.8 in/wc (10.0 kPa) Dual 5.0 in. (127 mm) 750kW Containerized Diesel Generator Set Cooling System Exhaust Manifold Type Radiator Design Coolant Capacity - Engine Only Coolant Capacity - Engine and Radiator Water Pump Design/Type Coolant Flow Heat Rejection to Coolant Fan Horsepower Dry Standard horizontal discharge 17.5 gal. (66 L) 66.5 gal (252 L) Belt Driven, Centrifugal 89 gal/min (337 L/min) 19625 BTU/min (344.8 kW) 56.0 hp (42 kW) Thermostat Inteligen Digital Genset Controller 185 °F (82 °C) Digital Controller Features Fuel System Recommended Fuel ASTM-D975/No.1 or No.2-D Fuel Pump Maximum Lift 6.8 ft. (2.1 m) Filter Micron Size 2 Total Fuel Flow 280 gal./hr. (1061 L/Hr.) Fuel Consumption Diesel @ % of load gal/hr L/hr 25% 15.2 57.5 50% 26.9 101.8 75% 39.4 149.1 100% 54.7 207.1 Lubrication System Type Oil Filters Oil Pan Capacity Oil Capacity with Filters Oil Pressure at Rated Speed Full Pressure System 3 Spin-on Full Flow 18.0 gal. (69.0 L) 25.0 gal. (94.1 L) 100 - 130 psi (690 - 896 kPa) Derating (60Hz) Ambient The engine power available up to 3300 ft. Altitude Temperature an d 77°F a t stand by r ating, w ithout derating. Maximum altitude capability is 7500 ft. For operation at higher altitudes Above 3300 ft. Above 77°F, and ambient temperatures, the power derate at 1.5% derate 0.4% sh ou ld b e d er a te d a cco r d in g to th e per 1000 ft. per 10°F following factors: ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Large graphic back-lit LCD display 128x64 pixel resolution Automatic and manual starting and stopping Phase sequence supervision Automatic shutdown/alarm function Input frequency 50-60 Hz Parameters adjustable via PC or iG keyboard Predefined and user definable configurations available. One configuration includes set of inputs/outputs and parameters Adjustable parameters for each configuration 6 LED indicators Push buttons for simple control 4 programmable outputs (out of 20 functions selection) 4 binary configuration inputs Lamp test during start up Real time clock Sealed membrane panel to IP65 180 x 113 mm front panel mounted case Speed measurement from magnetic pickup Oil pressure, Coolant temperature, Battery voltage and Fuel level measurements Running Hour Meter All Generator metering, kVAr, kW, V1-V3, Hz, I1-I3, kWh, kVAh Generator under/over voltage alarm/shutdown Generator under/over frequency alarm/shutdown Over Current alarm/shutdown Warm up and cooling functions Pre-lubrication function with timers Adjustable crank attempts Data logging Remote communications (RS232/Modbus) 750kW Containerized Diesel Generator Set Optional Features and Accessories Generator Set Container Genset-to-Genset Paralleling Control System ISO Trailer Chassis (40 ft.) Base Load-to-Utility Paralleling Control System Double-wall Fuel Tank (900-gallon capacity) Custom Outlet Panels Fluid Containment Rotary Voltage Selector Switch (High Wye/Low Wye Voltages) Manual Fuel Valves (For Internal or External Fuel Supply) Auxiliary Oil Reservoir with Level Control (15-gallon) Entrance Ladder (6-Step, Aluminum Construction) Centrifugal Oil Filter System Fueling Ladder (Aluminum Step Construction with Hand Rail) Oil Pan Heater with Thermostat Interior Lights (AC Work lights) Alternator Strip Heater AC Battery Charger with Shore Power Receptacle Custom Paint Colors (Artic White is Standard) SPECIAL OPTIONS AVAILABLE UPON REQUEST 40 ft Container Weight and Dimensions A B C D 96 in. (2,438 mm) 480 in. (12,192 mm) 163 in. (4,137 mm) 199 in (5,054 mm) Weight (Wet)* 37,540 lbs (17,030) Weight (Wet with trailer)* 44,280 lbs (20,085 kg) * Weight is approximate. Wet weight does not include fuel. Backfeed to a utility system can cause electrocution and/or property damage. Do not connect to any building’s electrical system except through an approved device. Specifications are subject to change without notice. Your MQ Power dealer is: MQ POWER POST OFFICE BOX 6254 CARSON, CA 90749 310-537-3700 • 800-421-1244 FAX: 310-632-2656 E-MAIL: [email protected] WEBSITE: www.mqpower.com © COPYRIGHT 2007, MQPOWER Rev. 2 (03-07) EGC750DD