RM113 TAKEMOTODENKI CORPORATION Harmonic Digital Power Meter Type RM-113 Display Range: RM−113−□□□1□□ Item Range Total Harmonic Current(A) CT Ratio:5∼800A, 1.00∼8.00kA/5A Total Harmonic Voltage(V) VT Ratio:110V∼77kV/110V, 220V THD(2∼15 Order Harmonic) A: 0∼120%, V: 0∼120% Effective Value A: AC5A, V: AC150V 5th harmonic conversion content A: 0∼120%, V: 0∼120% 5th harmonic conversion r.m.s. A: AC5A, V: AC150V Fundamental wave r.m.s. A: AC5A, V: AC150V nth harmonic conversion content A: 0∼120%, V: 0∼120% nth harmonic conversion r.m.s. A: AC5A, V: AC150V n :3, 4, 5, 7, 9, 11, 13, 15 t h Input 0: 1P 2W(105V/5A) 1: 1P 3W(105V/5A) 2: 3P 3W(220V/5A) 3: 3P 3W(110V/5A) Measuring Item A: A×3 B: V×3 Available Analog Output: r.m.s. in each phase, External Output 0: 2 Alarm Outputs Fundamental, Harmonics 3/4/5/7/9/11/13/15 r.m.s., 1: 4∼20mA +2 Alarm Outputs Harmonics 5th order conversion r.m.s., Total Harmonics 2: RS-485 THD, Harmonics 3/4/5/7/9/11/13/15 content, 4: 0∼1mA + 2 Alarm Outputs 5 th harmonic conversion content 5: 0∼10V + 2 Alarm Outputs Available Alarm Output: 6: 1∼5V +2 Alarm Outputs THD, Harmonics 3/4/5/7/9/11/13/15 content, 7: 0∼5V+2 Alarm Outputs Auxiliary Power Supply 5 th harmonic conversion content 1: 85∼ 264V AC Saving Max Value: Distortion, n th r.m.s., n th content, Rated External Operation Input 5 th conversion r.m.s., 5 th conversion 1: 85∼ 132V AC content, Total harmonics 3: 170∼264V AC (Reset/memory clear: turn power off) LED BRIGHTNESS No Symbol:Default Input Specification F: High Brightness LED・with Screen Filter ◆Voltage Ordering Information Example Operation Input Range: 0∼150V/0∼ 300V Overvoltage Strength:twice rated Voltage(9 times 0.5s, once 5s) ・Type:RM-113-3A111 1.2 times rated voltage(2 hours) ・Special Code: Consumption VA: approx. 0.6VA/ phase(at 220V), approx. Specification 0.3VA/ phase(at 110V) Standards:JIS C 1102, JIS C 1111 ◆Current Housing: Flame-proof Operation Input Range: 0∼100% of rated ampere ABS resin, UL94V-0 Overcurrent Strength: 40 times of rated current(twice 1 sec) Terminal Screw: Input Terminal/Power Terminal: M4 Output Terminal/External Terminal Input:M3 Digital Display:Below 5 digit, Orange LED(Measured Value), Green LED(Harmonic Order), Numeric Height 10mm Isolation:Between V/A mutual input, Input−Output− 10 times ((9 times 0.5s, once 5s) 1.2 times (2 hours) Consumption VA: approx. 0.1VA/phase ◆External Operation Input Consumption Current: 5mA Auxiliary Power―Display Switch Time for Reset:More than 0.3 s (available continuous energization) Sampling Cycle: 400μ s ◆Rated Frequency:50/60Hz shared Blackout Compensation: VT・ CT scale is stored in non-valatile memory. Lightning Impulse:All Electric Terminal−Earth Terminal 4.5kV RM113 Output Specification Outline Dimensional Drawing ◆Analog Output Range Load Resistance 4∼ 20mA 0∼ 500Ω 0∼ 1mA 0∼ 10kΩ 0∼ 10V DC Over 10kΩ 1∼ 5V DC Over 5kΩ 0∼ 5V DC Over 5kΩ Connector Pinouts Power Input ◆Alarm Output Output Alarm Output: 2 Contact Capacity: 110V DC 0.1A(Resistance Load) On resistance:typically 30Ω max 50Ω ◆Communication Output Standards:RS-485 Transmission Distance:Less than 1km (Maximal Unit: 32) ◆Power Terminal Aux. Power Cable: STP (CPEV-S0.9φ ) Terminator:Inside(Ter.Terminating Resistance Turnon with short circuit) Installation Auxiliary Power Supply:AC85∼264V 50/60Hz approx. 10VA ◆Input Terminal 1P 2W Conservation Temperature:-20∼70℃ Current Measurement Operating Temperature: -10∼50℃ Operating Humidity:30∼85%RH(non-condensing) Dimension:W110×H110×D126 mm Source Load Mass:Approx. 500g Others: ・Never install in places which are subject to direct sunlight. ・Never install in places which are subject to dust. Performance Tolerance : Measuring Item Tolerance THD(2∼ 15 th Harmonic) ±2.5% Total Harmonics ±1.5% Effective Value ±1.5% 5 th Harmonic Conversion Content Voltage Measurement Source Load ±2.5% 5 th Harmonic Conversion RMS ±1.5% Fundamental Wave RMS ±1.5% n th Harmonic Conversion Content ±2.5% n th Harmonic Conversion RMS ±1.5% 1P 3W Response Time(Within ±1% of the last value):Less than 1 sec Current Measurement Insulation Resistance : Between V Input― A Input− Output− Aux. power− earth, Over 100MΩ/DC500V Withstand Voltage:Between V Input―A Input−Output−Aux. power−earth, 2000V AC 1 min. Between electric circuit− earth 2000V AC 1 min. (No applying voltage to output terminal) Lightning Impulse:all electric terminal―earth terminal 4.5kV Source Load RM113 ◆Output Terminal Current Measurement( with 2 CTs) Without Analog Output Alarm 1 Source Alarm 2 Load Power RS-485 Output Terminator Voltage Measurement Source Load Power Display Switch Input Communication Output 3P 3W With Analog Output Current Measurement Ch 1 Output Source Alarm 1 Output Alarm 2 Output Load Power (*)Resetting the max value & alarm outputs Current Measurement( with 2 CTs) Source Load Voltage Measurement Source Load (※ )Be sure to earth when primary side is high voltage.