80 PLUS Verification and Testing Report
86.09%
84.93%
YES
TYPICAL EFFICIENCY (50% Load):
AVERAGE EFFICIENCY :
80 PLUS COMPLIANT:
1097
COOLERMASTER
RS-460-ASAA-D3
1083900201
2008
ATX12V
10/31/2008
Rated Specifications
Input Voltage
Input Current
Input Frequency
Rated Output Power
200
8
150
6
100
4
50
2
0
-50 0
PF
0.97
0.99
1.00
ITHD (%)
10.4%
5.1%
5.1%
Load
(%)
20%
50%
100%
Fraction Input
of Load Watts
107
266
546
Light
Typical
Full
0.006
0.009
0.012
0.015
-2
-100
-4
-6
Value
Units
-150
100-240
8-4
60-50
460
Volts
Amps
Hz
Watts
-200
-8
Time (s)
Voltage
Note: All measurements were taken with input voltage at 115 V nominal and 60 Hz.
IRMS
A
0.96
2.33
4.77
0
0.003
Current (A)
Input Current and Voltage Waveforms
Voltage (V)
Ecos ID #
Manufacturer
Model Number
Serial Number
Year
Type
Test Date
Current
Input AC Current Waveform (ITHD = 5.1%, 50% Load)
DC Terminal Voltage (V)/ DC Load Current (A)
-12V
3.3V
5V*
12V (cumulative of 12V1, 12V2, etc.)
11.4/0.1 3.4/2.7
5.1/2.7
11.8/5.5
11.5/0.2 3.3/6.8
5/6.7
11.9/13.9
11.6/0.4 3.3/13.5 4.9/13.5
11.9/27.7
Input and Output Power
600
5/0.4
5/1.1
4.9/2.2
Output
Watts
91
229
457
Efficiency
%
85.14%
86.09%
83.57%
Efficiency of the Power Supply
90%
500
5VSB
80%
400
Efficiency (%)
Power (Watts)
Input Watts
300
200
70%
60%
50%
Output Watts
40%
100
Efficiency %
0
20%
30%
50%
Loading (% of Rated Output Power)
100%
0%
25%
50%
75%
100%
Loading (% of Rated Output Power)