Product data sheet
822-5005-00-00
Characteristics
Xantrex - Grid Tie Solar PV Inverter GT500E - 500kW - 315 V AC
Xantrex GTE
GT500E
Grid tie inverter
Three phase
500 kW AC
ELECTRICAL
Photovoltaic power
560 kWp
Output voltage
315 V AC three phase
Output current
1040 A AC
Network frequency
50 Hz
60 Hz optional
Cos phi
> 0.99 above 20 % rated power
Harmonic distortion
< 3 % at rated power
Input voltage
<= 930 V DC open circuit
450 V DC reduced current above 820 V DC
450...880 V DC (495 -880 VDC for grid interactive option)
1000 V DC open circuit optional
Input current
1120 A DC
Efficiency
97.6 % (97.9% for grid interactive option) - European
98.1% (98.3% for grid interactive option)
Power consumption in W
< 100 W night-time
Topology
External MV transformer
Feature available
Standard integrated AC and DC disconnects
Optional external medium voltage isolation transformer
Optional communication kit for remote monitoring
Optional ground continuity relay or ground fuse
Optional grid interactive features incl. low voltage ride through & VAR control
Display type
LCD with Keypad
Messages display capacity
4 lines 20 Digits
Type of cooling
Forced convection (depending on temperature)
Device mounting
Floor mounted
Height
2112 mm
Width
2406 mm
Depth
605 mm
Product weight
1770 kg
ENVIRONMENT
IP degree of protection
IP20
Ambient air temperature for operation
-10...45 °C
Operating altitude
0...1500 m without derating
Relative humidity
0...95 % non-condensing
Standards
DK 5940
EN 50178
EN 61000-6-2
EN 61000-6-4
RD 1663
RD 661
BDEW
Marking
CE
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Main
Range of product
Device short name
Product or component type
Network number of phases
Nominal output power
Related documents