Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
D1SC-N/D1SA Series 7 Segment Display Unit 7 Segment Display Unit large(W32×H57mm) and high bright LED Features (B) Fiber optic sensor ● Selectable decimal(0 to 9) or hexadecimal(0 to 9, A to F) indication code Selectable positive or negative input logic Selectable serial or parallel data input method ● 7 Segment, red/green display (D1SA Series) ● Power source: 12-24VDC ● Wide range on signal input voltage level (Low: Max. 0-1.2VDC, High: 4.5-24VDC) ● Easy multi-stages connection (D1SA Series) ● Zero Blanking function (C) Door/Area sensor (D) Proximity sensor (E) Pressure sensor D1SC-N (F) Rotary encoder Applications ● Display for PLC ● Display for computer ● Various display (G) Connector/ Socket (H) Temp. controller Please read “Caution for your safety” in operation manual before using. (I) SSR/ Power controller D1SA Sereis (J) Counter Specifications Model D1SC-N Display method 7 Segment LED display(red) Power supply 12-24VDC Allowable voltage range 90 to 110% of rated voltage D1SA-RN Current consumption Max. 70mA Max. 35mA W32 × H57mm W11×H22mm ※2 Input D1SA-GN ※1 (K) Timer 7 Segment LED display(green) Character size Display character (A) Photo electric sensor (L) Panel meter (M) Tacho/ Speed/ Pulse meter • Decimal number : 0 to 9, decimal point • Hexadecimal number : 0 to 9, A to F, decimal point • Parallel : Parallel 4bit data, latch, zero blanking, decimal point • Serial : Serial 4bit or 5bit data, clock, zero blanking, latch, decimal point(for 4 bit input) (N) Display unit (O) Sensor controller Input resistance 12kΩ Input level High : 4.5-24VDC, Low : 0-1.2VDC 20kΩ Max. response CLOCK Max. 3kHz Output Data output (serial input), zero blanking output Input logic Selectable positive logic (PNP) or negative logic (NPN) (D1SC-N: by the function set switch, D1SA Series: by inner soldering) Noise strength ±300V the square wave noise (pulse width: 1us) by the noise simulator (P) Switching mode power supply (Q) Stepper motor& Driver&Controller Environ Ambient temperature 0 to 60℃, storage : -10 to 85℃ -ment Ambient humidity 35 to 85%RH, storage: 35 to 85%RH Accessory Housing[5264-10], Terminal[5263(PBT)], Sub-PCB for Connector(CT-10S), Cap multi-stage connection Unit weight Approx. 100g (R) Graphic/ Logic panel (S) Field network device Approx. 22g(including right/left caps) (T) Software ※1: It is option ※2: Only D1SC-N supports Minus displaying. ※The max. response CLOCK is when the duty ratio is 1:1. ※Environment resistance is rated at no freezing or condensation. (U) Other N-21 D1SC-N/D1SA Series Terminal layout and function D1SC-N ① Function set jumper(SW1) ① OFF ON SW1 ③ CN2 1 ③ ON ON ON OFF 10 ②5 SW2 JP1 1 OFF <Factory default> OFF Function Pos. logic(NPN) Neg. logic(PNP) Input logic Jumper 10 CN1 (rear terminal layout) 1 Jumper pin ON 1 2 3 45 ② Function set switches(SW2, JP1) ON No. ON OFF ③ Input/Output terminals Input Parallel input JP1 <Factory default> Serial input Terminal Code Function Code Function 1 V+ VCC 12-24VDC 12-24VDC ON OFF Function 2 D0 N·C Do not connect anything 1 Decimal Hexadecimal Characters 3 D1 CK Clock input 2 Parallel Serial Input 4 D2 DI Data input 4Bit 5Bit Serial input 5 D3 DO Data output 4 Used Not used Serial data output 6 BI Zero blanking input BI Zero blanking input 5 Used Not used Zero Blanking 7 BO Zero blanking output BO Zero blanking output 8 LE Latch input Latch input 9 DP Decimal point input DP 10 GND 0V SW2 3 JP1 ※1 Minus 7Segment Minus ※1: For Serial input, set this as ON. Data input LE Decimal point input GND 0V ※Terminals of CN1 and CN2 is corresponding 1:1. For Parallel input, set this as OFF. D1SA Series ① Function set switches ON OFF Function Decimal Hexadecimal Characters S2 Parallel Serial Input ① S3 4Bit 5Bit Serial input S4 J2 J1 S3 S2 S1 J1 Used Not used Serial data output ② <Factory default> ※ON = No. S1 (Short) OFF = J2 Used Not used Zero Blanking S4 Neg. logic(NPN) Pos. logic(PNP) Input logic ※1 ※1: For Serial input, set this as ON. For Parallel input, set this as OFF. (Open) ② Input/Output terminals 10 Terminal 9 1 2 3 4 5 6 7 8 9 10 8 7 6 5 4 3 2 1 N-22 Input Parallel input Serial input Code Function Code Function V+ D0 D1 D2 D3 BI BO LE DP GND 12-24VDC VCC N·C CK DI DO BI BO LE DP GND 12-24VDC Do not connect anything Clock input Data input Data output Zero Blanking input Zero Blanking output LATCH input Point input 0V Data input Zero Blanking input Zero Blanking output LATCH input Point input 0V 7 Segment Display Unit Block diagram (A) Photo electric sensor Parallel input V+ GND Power (B) Fiber optic sensor Stablize power D0 D1 D2 D4 LATCH - LE Decimal point -DP Data input Input Input circuit circuit Zero blanking input - BI (C) Door/Area sensor DECODER DRIVER (D) Proximity sensor (E) Pressure sensor Input circuit Input circuit Zero blanking control circuit Zero blanking output - BO (F) Rotary encoder Serial input V+ GND Power (G) Connector/ Socket Stablize power CLOCK - CK Data input - DI LATCH - LE Decimal point - DP Input Input circuit circuit DECODER DRIVER Input circuit circuit Input Zero blanking control circuit (H) Temp. controller (I) SSR/ Power controller Data output - DO Zero blanking input - BI Zero blanking output - BO (J) Counter (K) Timer ※The ② pin is not used. Dimensions (unit: mm) ● Panel cut-out D1SC-N 2.3 72 25.7 72×N-3.5 ※N: Number of units ※Panel thickness: 2 to 4mm (M) Tacho/ Speed/ Pulse meter (N) Display unit (O) Sensor controller 90.5 90 96 57 32 (L) Panel meter (P) Switching mode power supply (Q) Stepper motor& Driver&Controller 10° Accessories ■ CN1 : Connector specification OFF ON SW1 CN2 ■ CN2 : Connector for multi-stage ● Connector maker: Korea Morex ● This connector must be used with • Housing: 5264-10 connection PCB • Header: 5264-10A(Straight) ● CN1 and CN2 must be connected as • Terminal: 5263(PBT) below drawing. 8mm ● Using cable specification • AWG28 to 22(cable diameter: Max. Ø1.9mm) • Shielding length of wire cover: 2.4 to 2.9mm CN1 27mm Header Housing[5264-10] Terminal[5263(PBT)] Multi-stage connector N-23 (R) Graphic/ Logic panel (S) Field network device (T) Software (U) Other D1SC-N/D1SA Series D1SA Series (unit: mm) ● Panel cut-out 33 31 6 B A ● Panel cut-out chart 54 3.5 35 22 11 Accessory ● Connector(Model : CT-10S) 19 32 30±0.1 2 52 50±0.1 3 72 70±0.1 4 92 90±0.1 5 112 110±0.1 6 132 130±0.1 7 152 150±0.1 8 172 170±0.1 7.5 ● D1SA-RN: DAR(L) -R (left/right 1 set) ● D1SA-GN: DAR(L) -BL (left/right 1 set) ※Cap is optional (1set). 23 7.5 32 42 2-Ø3.4 B(20×N+10) 1 Sold separately ● CAP 13.5 37 7.5 Digit(N) A(20×N+12) Input data chart Indication Minus Negative input ※1 Positive input 7 Segment Hexa Hexa Decimal decimal decimal Decimal D C B A D C B A Blank Blank H H H H L L L L Blank Blank H H H L L L L H H H L H L L H L H H L L L L H H H L H H L H L L H L H L L H L H H L L H L H H L H L L L L H H H L H H H H L L L Blank Blank N-24 Blank L H H L H L L H Blank Blank L H L H H L H L Blank Blank L H L L H L H H Blank Blank L L H H H H L L Blank Blank L L H L H H L H Blank Blank L L L H H H H L Blank Blank L L L L H H H H ※When BI terminal connect GND, “0” is displayed. When BI terminal is open, it is blank (not display) ※"X" : Either high or low level can be input. ※1: Only D1SC-N supports Minus display. Set the rear JP1 as OFF. ※Blank: If input signal as input DATA, it does not display. 7 Segment Display Unit Input circuit (A) Photo electric sensor D1SC-N ● Positive logic(PNP) input (SW1: OFF) 10kΩ ● Negative logic(NPN) input (SW1: ON) (B) Fiber optic sensor +5V 20kΩ Input IC (C) Door/Area sensor 12kΩ 10kΩ 12kΩ 20kΩ IC Input (D) Proximity sensor (E) Pressure sensor ※Input level - High : 4.5-24VDC, Low: 0-1.2VDC D1SA Series ● Positive logic(PNP)input (SW1: OFF) (F) Rotary encoder ● Negative logic(NPN) input (SW1: ON) (G) Connector/ Socket 5V 100kΩ IC Input 20kΩ 20kΩ ※Input level (H) Temp. controller 100kΩ High : 4.5-24VDC Low: 0-1.2VDC IC Input (I) SSR/ Power controller Data input method (J) Counter Parallel input ● 4Bit Static Parallel input(ex: displays ABCD.) 103 102 101 (K) Timer 100 4Bit Data3+Point3 4Bit Data2+Point2 4Bit Data3+Point3 HLHL+L 4Bit Data2+Point2 HLHH+L 4Bit Data1+Point1 HHLL+L 4Bit Data0+Point0 HHLH+H (L) Panel meter (M) Tacho/ Speed/ Pulse meter LATCH 4Bit Data1+Point1 (N) Display unit 4Bit Data0+Point0 LATCH 103 ● 4Bit Dynamic Parallel input(ex: displays ACE007.) 105 104 101 100 102 101 ※Clock: Max. 3kHz Pw 4Bit Data HLHL HHLL (O) Sensor controller 100 HHHL LLLL LLLL (P) Switching mode power supply LHHH (Q) Stepper motor& Driver&Controller Point LATCH 5 4Bit Data LATCH 4 Point LATCH 3 LATCH 5 LATCH 4 LATCH 2 t1 t2 (R) Graphic/ Logic panel t3 LATCH 1 LATCH 0 (S) Field network device LATCH 1 LATCH 0 (T) Software 10 5 104 103 10 2 10 1 10 0 ※Pw=t1+t2+t3 Pw: 0.33ms(Min.) t1: 0.05ms(Min.) → Data LATCH t2: 0.23ms(Min.) → Data move t3: 0.05ms(Min.) → Data N-25 (U) Other D1SC-N/D1SA Series Serial input ※Clock max. 3kHz ※In case of positive logic (PNP), hexadecimal number ● 6Bit Serial input(ex: displays -20.8) ta: 0.23ms(Min.) tw: 0.05ms(Min.) START tw LATCH 0.33ms SHIFT ta CLOCK D1 L L D0 Data L D3 L D2 D1 Data ※1 L D0 H L D3 D2 L D1 Data L D0 LSB(0) H L D2 MSB(0) Data D3 LSB(1) L D0 MSB(1) L D1 LSB(2) MSB(3) H L D2 MSB(2) L D3 LSB(3P) 1Bit Data ※2 ※1: To display Minus, set the rear JP1 as OFF. ※2: In case of 4Bit Serial input, to display decimal point, connect DP of the rear input terminal to V+. In case of negative logic(NPN), connect DP to GND. ● 5Bit SeriaI input(ex: displays A25.0) ta: 0.23ms(Min.) tw: 0.05ms(Min.) START LATCH tw w ta a 0.33ms SHIFT CLOCK L D3 H L D2 D1 Data H D0 L L D4 D3 L D2 Data L D1 L D0 LSB(0) H D4 MSB(0) L D0 LSB(1) Data H D1 Point L D2 MSB(1) L D3 LSB(2) L D4 Point Data L D0 MSB(2) H D1 Point L D2 LSB(3P) H D3 MSB(3) L D4 Point 1Bit Data Multi-stage connection method Parallel input : 4digit ※The below connection is example of D1SC-N. Fro D1SA, connection is same but the order of pin is reverse. (connector image(refer to N-14 page of the 9th catalogue) ※CN1, CN2 terminals of D1SC-N corresponds 1:1 and it is able to connect as CN1 depending on the need. ※When not using Zero Blanking, connect BI terminal to GND. ● Static parallel input(Zero blanking method): These diagrams are to wire at rear layout of the unit. CN2 V+ D0 D1 D2 D3 BI BO LE DP GND 1 10 DP DP DP D3 D3 D3 D3 D2 D2 D2 D2 D1 D1 D1 D1 D0 D0 D0 CN2 1 V+ D0 D1 D2 D3 BI BO LE DP GND 10 1 10 CN1 CN1 100 N-26 DP CN2 1 V+ D0 D1 D2 D3 BI BO LE DP GND 10 1 10 D0 CN2 1 V+ D0 D1 D2 D3 BI BO LE DP GND 10 1 10 CN1 CN1 101 102 Data input 103 1 V+ From next digit (over 5digits) BO LATCH GND 10 7 Segment Display Unit ● Dynamic parallel input(Zero blanking method) : These diagrams are to wire at rear layout of the unit. LATCH 0 LATCH 1 Data input LATCH 2 (B) Fiber optic sensor LATCH 3 CN2 CN2 1 V+ D0 D1 D2 D3 BI BO LE DP GND V+ D0 D1 D2 D3 BI BO LE DP GND 1 10 CN2 1 10 1 10 V+ D0 D1 D2 D3 BI BO LE DP GND 10 1 CN1 CN1 10 CN2 1 10 10 1 CN1 0 10 1 V+ D0 D1 D2 D3 BI BO LE DP GND (C) Door/Area sensor V+ D0 D1 D2 D3 BO (D) Proximity sensor From next digit (over 5digits) DP GND 10 10 10 2 10 3 (G) Connector/ Socket Serial input : 4digit ● Serial input (Zero blanking method) : These diagrams are to wire at rear layout of the unit. (H) Temp. controller DI Data input CN2 VCC CN2 1 CN2 1 CK CK CK DI DO DI DO DI DO BI BI BI BI BO LE DP GND BO LE DP GND BO LE DP GND BO LE DP GND 10 10 1 CN1 10 10 1 100 VCC CK From next digit (over 5digits) BO LATCH (K) Timer (L) Panel meter CN1 101 102 103 (M) Tacho/ Speed/ Pulse meter Zero blanking method? It is to remove "0" indication which is no meaning. Ex1) When displaying 10 ① Using Zero Blanking ② Not using Zero Blanking 103 102 101 100 ("0" of 103, 102 are no meaning and they are not displayed.) (N) Display unit (O) Sensor controller 103 102 101 100 (P) Switching mode power supply ※If indication data is "101", meaningful tens place "0" will be displayed. Using Zero Blanking for multi-stage (Q) Stepper motor& Driver&Controller Set no.5 (Zero Blanking output) of the rear function set switch(SW2) as ON. For 10(0) to display '0', set this as OFF. 1) Using Zero Blanking (R) Graphic/ Logic panel V+ BO BI 10 3 10 2 10 1 10 BI BO BI BO BI (S) Field network device BO 0 (T) Software 10 3 10 2 10 1 10 GND 0 2) Not using Zero Blanking (U) Other BO BI 10 3 10 2 10 1 10 (J) Counter GND 10 10 1 CN1 (I) SSR/ Power controller 1 VCC VCC CK 10 10 1 CN2 1 VCC DI DO CN1 (E) Pressure sensor (F) Rotary encoder CN1 1 (A) Photo electric sensor BI BO BI BO BI BO 0 GND 103 102 101 GND 100 N-27 D1SC-N/D1SA Series The application of PLC program[Serial input type] 1. Display Unit D1SA2. Data input type: Serial 3. Connection type: See serial connection type when using more than 2EA 4. Display result: "A" Display 5. PLC: LSIS(LS Industrial Systems), MASTER-K Series 6. When using serial type, use transistor output card of PLC 7. Negative logic(NPN) P000 [ SET S00.01 ] M000 [ SET S00.02 ] M001 [ SET S00.03 ] M000 [ SET S00.04 ] M001 [ SET S00.05 ] M000 [ SET S00.06 ] M001 [ SET S00.07 ] M000 [ SET S00.08 ] M001 S00.09 Shift register [ SET S00.09 ] M000 [ SET S00.00 ] S00.01 Reset ( M000 ) S00.03 S00.05 S00.07 S00.09 S00.02 (M001) S00.04 S00.06 S00.08 S00.02 (P010) CLOCK output S00.04 S00.06 S00.08 P000 S00.01 ( MOV h000A M01 ) M013 (P011) S00.02 S00.03 HEX "A" value Transmission order to M01 HEX "A" value data output "A" display M012 S00.04 S00.05 M011 S00.06 S00.07 M010 S00.08 S00.09 (P012) [ END ] ※Visit our web site(www.autonics.com) to download various applications of PLC program. N-28 LATCH Output