INSTALLATION INSTRUCTIONS Wiring Connection for : TC-9102-0110 / 1110 TC-9102-0115 / 1115 24 VAC PWM Control Signal F + + + 0 - 10 VDC Fan Speed _ 41 40 31 30 Aux. Output CLG Output HTG Output Analog Inputs Digital common 10 11 12 13 com com 14 15 20 21 22 23 24 com phase _ _ 61 60 Digital Inputs (common) Groun d 3 2 1 Power Supply System 91 N2 Analog Communication Bus Common RT+ RT- COM SH com Window Mode Led N.T.C. Contact Occupancy Sensor Sensor - R.S.P. Mounting dimensions of enclosure SEPARABLE CONNECTORS F Use on Solenoid Valve Power Module: - VA-7400-8950 for TC-9102-x11x models manufactured before week 9616. - VA-7400-8951 for TC-9102-x11x models manufactured starting week 9619. - Digital Inputs of instrument are factory jumpered. Scrap jumpers when Window Contact and / or Occupancy sensor are connected. P/N 24-85638-145 Rev. A INSTALLATION INSTRUCTIONS Wiring Connection for : TC-9102-0111 / 1111 TC-9102-0116 / 1116 24 VAC External supply for fan 220-240 VAC N (common) PWM Control Signal F Ground L Fan 71 70 + + _ _ ON-OFF 61 60 41 Auxiliary Output 40 31 com 12 13 com 3 14 15 20 21 com Window Mode Led N.T.C. Contact Occupancy Sensor Sensor - 22 23 2 1 Power Supply System 91 N2 Analog Communication Bus Common Analog Inputs Digital common 11 30 CLG Output HTG Output Digital Inputs 10 phase 24 RT+ RT- COM SH com R.S.P. Mounting dimensions of enclosure SEPARABLE CONNECTORS F Use of Power Module with Solenoid Valve: - VA-7400-8950 for TC-9102-x11x models manufactured before week 9616. - VA-7400-8951 for TC-9102-x11x models manufactured starting week 9619. - Digital Inputs of instrument are factory jumpered. Scrap jumpers when Window Contact and / or Occupancy sensor are connected. P/N 24-85638-226 Rev. A INSTALLATION INSTRUCTIONS Wiring Connection for : TC-9102-0221 / 1221 TC-9102-0226 / 1226 - For UL / CSA approval : Output - 3 A, 120 V ac, General Purpose 1/8 hp, 120 V ac - External supply for fan 220-240 VAC N L Fan 71 70 61 CLASS 2 24 VAC (common) + + _ _ ON-OFF 60 Auxiliary Output u Digital Inputs 41 40 31 30 CLG Output HTG Output com 12 13 com 14 15 20 21 com Window Mode Led N.T.C. Contact Occupancy Sensor Sensor - 22 23 3 2 1 Power Supply System 91 N2 Analog Communication Bus Common Analog Inputs Digital common 10 11 phase Ground Analog 0 - 10 VDC 24 RT+ RT- COM SH com R.S.P. Mounting dimensions of enclosure SEPARABLE CONNECTORS u Apply a maximum torque of 4 lb. in. to line voltage field wiring terminals. - Digital Inputs of instrument are factory jumpered. Scrap jumpers when Window Contact and / or Occupancy sensor are connected. P/N 24-85638-242 Rev. A INSTALLATION INSTRUCTIONS Wiring Connection for : TC-9102-0112 / 1112 TC-9102-0117 / 1117 External supply for fan 220-240 VAC 24 VAC 3 Speed N L Fan Lo w 71 PWM Control Signal F 70 Med. 63 62 61 60 com com _ CLG Output 31 30 3 HTG Output 14 15 com Window Mode Led N.T.C. Contact Occupancy Sensor Sensor - 22 23 24 com R.S.P. 50 1 System 91 N2 Communication Analog 20 21 2 Power Supply Analog Inputs Digital common 12 13 _ 41 40 Digital Inputs 11 + phase High Auxiliary Output 10 + (common) Ground 51 52 RT+ RT- COM SH com Fan Control Override Mounting dimensions of enclosure SEPARABLE CONNECTORS F Use of Power Module with Solenoid Valve: - VA-7400-8950 for TC-9102-x11x models manufactured before week 9616. - VA-7400-8951 for TC-9102-x11x models manufactured starting week 9619. - Digital Inputs of instrument are factory jumpered. Scrap jumpers when Window Contact and / or Occupancy sensor are connected. P/N 24-85638-307 Rev. A TC-9102-S9336 Wiring connections External supply for fan and heating output 220-240 VAC L N 24 VAC 3 Speed (common) phase Ground Fan ON-OFF 70 71 Low Med. High 63 62 61 60 41 40 Htg.Outpu t Auxiliary Output Digital Inputs 11 12 13 Analog Inputs com com 14 15 20 21 22 23 com Mode Led Window Occupancy Contact N.T.C. Sensor Sensor 1 Power Supply Analog common Digital common 10 2 3 24 System 91 N2 Communication Bus RT+ RT- COM SH com R.S.P. Mounting dimensions of enclosure 120 SEPARABLE CONNECTORS 6 108 31 - Digital inputs of instrument are factory jumpered. Scrap jumpers when Window contact and/or Occupancy sensor are connected. IMPORTANT: All outputs are with internal supply connection P/N 24-85638-412 INSTALLATION INSTRUCTIONS Wiring Connection for : TC-9102-0330 CLASS 2 24 VAC (common) (2) D.O. phase Ground (2) D.O. + 0 - 10 VDC Fan Speed Control _ 61 60 2 42 Aux. Output Digital Inputs 1 41 40 2 32 Cooling Output 11 com 12 13 Analog Inputs com 14 15 20 21 22 31 30 Heating Output Analog Common Digital common 10 1 23 com Window Mode Led N.T.C. Contact Occupancy Sensor Sensor - R.S.P. 2 1 Power Supply System 91 N2 Communication Bus 24 com 3 RT+ RT- COM SH Mounting dimensions of enclosure SEPARABLE CONNECTORS - Digital Inputs of instrument are factory jumpered. Scrap jumpers when Window Contact and / or Occupancy sensor are connected. P/N 24-85638-595 Rev. A INSTALLATION INSTRUCTIONS Wiring Connection for : TC-9102-0331 - For UL / CSA approval : Output - 3 A, 120 V ac, General Purpose 1/8 hp, 120 V ac - External supply for fan 220-240 VAC N CLASS 2 24 VAC (common) (2) D.O. phase Ground (2) D.O. L Fan ON-OFF 2 71 70 61 60 42 Auxiliary Output u 1 41 40 2 32 Cooling Output Digital Inputs 11 com 12 13 Analog Inputs com 14 15 20 21 com Window Mode Led N.T.C. Contact Occupancy Sensor Sensor - 22 31 30 3 Heating Output Analog Common Digital common 10 1 23 2 1 Power Supply System 91 N2 Communication Bus 24 RT+ RT- COM SH com R.S.P. Mounting dimensions of enclosure SEPARABLE CONNECTORS u Apply a maximum torque of 4 lb. in. to line voltage field wiring terminals. - Digital Inputs of instrument are factory jumpered. Scrap jumpers when Window Contact and / or Occupancy sensor are connected. P/N 24-85638-609 Rev. A INSTALLATION INSTRUCTIONS Wiring Connection for : TC-9102-0332 / 1332 - For UL / CSA approval : Output - 3 A, 120 V ac, General Purpose 1/8 hp, 120 V ac - External supply for fan 220-240 VAC 3 Speed N L 24 VAC (common) (2) D.O. 70 63 Med. 62 High 2 61 60 42 Auxiliary Output u 1 41 com 12 13 com 32 1 31 30 3 Heating Output 14 15 2 1 Power Supply System 91 N2 Communication Analog Inputs Digital common 11 40 2 Cooling Output Digital Inputs 10 phase Ground (2) D.O. Fan Low 71 CLASS 2 Analog common 20 21 com Window Mode Led N.T.C. Contact Occupancy Sensor Sensor - 22 23 24 com R.S.P. 50 51 52 RT+ RT- COM SH com Fan Control Override Mounting dimensions of enclosure SEPARABLE CONNECTORS u Apply a maximum torque of 4 lb. in. to line voltage field wiring terminals. - Digital Inputs of instrument are factory jumpered. Scrap jumpers when Window Contact and / or Occupancy sensor are connected. P/N 24-85638-617 Rev. B INSTALLATION INSTRUCTIONS Wiring Connection for : TC-9102-1552JAA External supply for fan Max. 230 VAC N L P.A.T. 100 VAC P.A.T. 100 VAC M M Fan Low 71 3 Speed 70 63 Med. 62 Close High 61 60 42 41 Open Close 40 32 100 VAC Open 31 30 3 Auxiliary Output com 12 13 com System 91 N2 Communication Analog Inputs Digital common 11 1 Power Supply Digital Inputs 10 2 14 15 Analog common 20 21 com Window Mode Led N.T.C. Contact Occupancy Sensor Sensor - 22 23 24 com R.S.P. 50 51 52 RT+ RT- COM SH com Fan Control Override Mounting dimensions of enclosure SEPARABLE CONNECTORS - Digital Inputs of instrument are factory jumpered. Scrap jumpers when Window Contact and / or Occupancy sensor are connected. P/N 24-85638-765 Rev. A INSTALLATION INSTRUCTIONS Wiring Connection for : TC-9102-1222JAA External supply for fan Max. 230 VAC N 100 VAC Analog 0 - 10 VDC L Fan Low 71 3 Speed 70 63 Med. 62 61 60 41 com 13 com _ 40 31 30 3 14 15 2 1 Power Supply System 91 N2 Communication Analog Inputs Digital common 12 _ CLG Output HTG Output Digital Inputs 11 + High Auxiliary Output 10 + Analog common 20 21 com Window Mode Led N.T.C. Contact Occupancy Sensor Sensor - 22 23 24 com R.S.P. 50 51 52 RT+ RT- COM SH com Fan Control Override Mounting dimensions of enclosure SEPARABLE CONNECTORS - Digital Inputs of instrument are factory jumpered. Scrap jumpers when Window Contact and / or Occupancy sensor are connected. P/N 24-85638-773 Rev. A INSTALLATION INSTRUCTIONS Wiring Connection for : TC-9102-1337S3 External Supply for fan 230 VAC 24 VAC N ON-OFF reversing valve L Fan ON-OFF compressor (common) phase Ground Low High Med. Speed Speed Speed 71 70 63 62 61 60 42 Auxiliary Output 41 40 32 Cooling Output 31 30 3 Heating Output 2 1 Power Supply For Connectors 60...71 when using multi-stranded wire apply a cable sleeve to the cable end Digital Inputs Digital common 10 11 com 12 13 com System 91 N2 Communication Analog Inputs 14 15 Analog common 20 21 com Window Alarm Mode Led N.T.C. Contact Sensor Sensor - 22 23 24 com R.S.P. 50 51 52 RT+ RT- COM SH com Fan Control Override Mounting dimensions of enclosure SEPARABLE CONNECTORS - Digital Inputs of instrument are factory jumpered. Scrap jumpers when Window Contact and / or Alarm sensor are connected. P/N 24-85638-781 TC-9102-9336S Wiring connections External supply for fan and M 3 Speed P.A.T. heating output 24 VAC 220-240 VAC D.A.T. L N 24 VAC Fan E-H 24 VAC (common) Ground phase ON-OFF 24 VAC 70 71 Low Med. High 63 62 61 2 60 41 40 Htg.Outpu t Auxiliary Output Analog Inputs Digital Inputs Digital common 10 11 12 13 com com 14 15 Analog 20 21 22 23 24 com Window Contact Occupancy Mode Led N.T.C. or Sensor DIR/REV- 1 32 31 30 3 50 51 52 1 Power Supply Cooling Output Fan Control Override 2 System 91 N2 Communication RT+ RT- COM SH com R.S.P. Mounting dimensions of enclosure SEPARABLE CONNECTORS - Digital inputs of instrument are factory jumpered. Scrap jumpers when Window contact and/or Occupancy sensor are connected. IMPORTANT: All outputs are with internal supply connection P/N 24-85638-986 INSTALLATION INSTRUCTIONS Wiring Connection for : TC-9102-8009SM External supply for fan 220-240 VAC 24 VAC (common) Ground Analog 0 - 10 VDC N LOAD 1 L 70 63 62 61 60 12 13 com 31 30 3 HTG Output 14 15 2 1 Power Supply System 91 N2 Communication Analog Inputs Digital common com _ CLG Output Digital Inputs 11 _ 41 40 Auxiliary Output 10 + LOA D N 71 + phase Analog 20 21 com Window Mode Led N.T.C. Contact Occupancy Sensor Sensor - 22 23 24 com R.S.P. 50 51 52 RT+ RT- COM SH com Fan Control Override Mounting dimensions of enclosure SEPARABLE CONNECTORS - Digital Inputs of instrument are factory jumpered. Scrap jumpers when Window Contact and / or Occupancy sensor are connected. P/N 24-85638-1052 Wiring connection for: TC-9109-1209 24 VAC (common) Analog 0 - 10 VDC CLG OUTPUT Digital Inputs Analog 0 -10 VDC HTG OUTPUT + + _ _ 61 60 41 40 31 Aux Output Output 2 Output 1 Analog Inputs Analog common Digital common 10 11 12 13 com com 14 15 20 21 22 23 com com Mode Led Window N.T.C. Contact Occupancy Sensor Sensor * * R.S.P. 24 30 phase Ground 3 2 1 Power Supply System 91 N2 Communication Bus RT+ RT- COM SH Mounting dimensions of enclosure 120 SEPARABLE CONNECTORS 6 108 31 - Digital inputs of instrument are factory jumpered. Scrap jumpers when Window contact and/or Occupancy sensor are connected. P/N 24-85638-102 Rev. A INSTALLATION INSTRUCTIONS Wiring Connection for : TC-9109-1225S 24 VAC (common) Analog 0 - 10 VDC 61 + + _ _ _ 41 Aux Output Digital Inputs 10 11 12 13 40 31 CLG Output Analog Inputs 14 15 com 20 Ground + 60 21 com 22 23 phase 30 3 HTG Output Analog Common 24 2 1 Power Supply System 91 N2 Communication Bus RT+ RT- COM SH com - Red White Blue Dew point sensor HX-9100-8001 Mode Led N.T.C. Sensor R.S.P. Mounting dimensions of enclosure SEPARABLE CONNECTORS - Digital input of instrument is factory jumpered. Scrap jumper when Occupancy sensor is connected between 12 - 13. P/N 24-85638-803 INSTALLATION INSTRUCTIONS Wiring Connection for : TC-9112-0110 / 1110 TC-9112-0115 / 1115 24 VAC (common) PWM Control Signal F 0 - 10 VDC Fan Speed Control 61 + + + _ _ _ 60 41 Aux. Output Digital Inputs 10 11 com 12 13 14 15 20 com 31 30 3 CLG Output HTG Output Analog Inputs Digital common 40 phase Ground 2 1 Power Supply System 91 N2 Communication Bus 21 RT+ RT- COM SH com Window Mode Led N.T.C. Contact Occupancy Sensor Sensor - Mounting dimensions of enclosure SEPARABLE CONNECTORS F Use on Solenoid Valve Power Module: - VA-7400-8950 for TC-9112-x11x models manufactured before week 9616. - VA-7400-8951 for TC-9112-x11x models manufactured starting week 9619. - Digital Inputs of instrument are factory jumpered. Scrap jumpers when Window Contact and / or Occupancy sensor are connected. P/N 24-85638-153 Rev. A INSTALLATION INSTRUCTIONS Wiring Connection for : TC-9112-0111 / 1111 TC-9112-0116 / 1116 24 VAC External supply for fan 220-240 VAC N PWM Control Signal F L Fan 71 70 61 60 41 Digital common com 12 _ _ 13 com 40 31 30 3 CLG Output HTG Output Digital Inputs 11 + phase Ground ON-OFF Auxiliary Output 10 + (common) 14 15 Analog Inputs 20 2 1 Power Supply System 91 N2 Communication Bus 21 RT+ RT- COM SH com Window Mode Led N.T.C. Contact Occupancy Sensor Sensor - Mounting dimensions of enclosure SEPARABLE CONNECTORS F Use of Power Module with Solenoid Valve: - VA-7400-8950 for TC-9112-x11x models manufactured before week 9616. - VA-7400-8951 for TC-9112-x11x models manufactured starting week 9619. - Digital Inputs of instrument are factory jumpered. Scrap jumpers when Window Contact and / or Occupancy sensor are connected. P/N 24-85638-234 Rev. A INSTALLATION INSTRUCTIONS Wiring Connection for : TC-9112-0112 / 1112 TC-9112-0117 / 1117 External supply for fan 220-240 VAC 24 VAC 3 Speed N L Fan Low 71 70 63 Med. 62 61 60 41 com 13 com _ _ 40 31 30 3 14 15 2 1 Power Supply System 91 N2 Communication Analog Inputs Digital common 12 + CLG Output HTG Output Digital Inputs 11 + phase Ground High Auxiliary Output 10 (common) PWM Control Signal F Analog common 20 21 com Window Mode Led N.T.C. Contact Occupancy Sensor Sensor - 22 23 24 50 51 52 RT+ RT- COM SH com Fan Control Override Mounting dimensions of enclosure SEPARABLE CONNECTORS F Use of Power Module with Solenoid Valve: - VA-7400-8950 for TC-9112-x11x models manufactured before week 9616. - VA-7400-8951 for TC-9112-x11x models manufactured starting week 9619. - Digital Inputs of instrument are factory jumpered. Scrap jumpers when Window Contact and / or Occupancy sensor are connected. P/N 24-85638-315 Rev. A INSTALLATION INSTRUCTIONS Wiring Connection for : TC-9112-8000 / 8001 External supply for fan Max. 240 VAC 24 VAC (common) phase Analog 0 - 10 VDC N L Fan 71 70 63 62 61 60 41 Auxiliary Output com 12 13 com Common Fan Alarm Satus - _ _ 40 31 30 3 14 15 2 1 Power Supply System 91 N2 Communication Analog Inputs Digital common 11 + CLG Output HTG Output Digital Inputs 10 Ground + Analog common 20 21 22 com TE-9100-8501 Return Air Sensor 23 24 50 51 52 RT+ RT- COM SH com TE-9100-8501 Supply Air Sensor Mounting dimensions of enclosure SEPARABLE CONNECTORS - Digital Inputs of instrument are factory jumpered. Scrap jumpers when Digital Inputs are connected. P/N 24-85638-692 Rev. A