WiLARM-ContactID EasyPhone
GSM Module
Installation Guide
Version: 2.0
WiLARM-ContactID EasyPhone
GSM Module
Installation Guide
Version: 2.0
Content
Main functions and operation of the GSM module……………………………………………………….
3
Parts of the module………………………………………………………………………………………………………..
3
Mini USB connector…………………………………………………………………………………………………..
4
Terminal contacts…………..…………………………………………………………………………………………
4
Power supply…………………………………………………………………………………………………………….
4
Input ………………………………………………………………………………………..………………………………
4
LEDs…………………………………………………………………………………………………………..…………….
4
LED operation chart…………………………………………………………………………………………………
5
Push button…………………………………………………………………………..…………………..……………
5
Deleting the configuration (master reset)………………………………………………….…….……..
5
Refreshing the internal firmware…………………………………………………………..……………….
6
SIM holder……………………………………………………………………..………………………………………
6
Antenna connector…………………………………………………………………………………………………
6
Telephone circuit……………………………………………………………………………………………………
6
Prepare for the installation……………………………………………………………………………………………
7
Programming with SMS commands……………………………………………………………..……………….
7
Controlling the GSM module with commands……………………………………………………………….
7
Troubleshooting………………………………………………………………………………………………………….
8
2
WiLARM-ContactID EasyPhone
GSM Module
Installation Guide
Version: 2.0
Main functions and operation of the GSM module
The alarm center starts a ContactID communication and the module forwards it as a GSM phone call
to the called number of the monitoring centre. The standard ring voltage appears on the phone line
simulator in case of incoming calls (for example alarm center during teleprogramming).
Parts of the module
3
WiLARM-ContactID EasyPhone
GSM Module
Installation Guide
Version: 2.0
Mini USB connector
The inner software of the module can be refreshed via the mini USB connector. The
“WiLARM_Upgrader” software documentation includes the whole detailed user manual.
Terminal contacts
The power supply and the alarm system’s Tip/Ring input can be connected to the GSM module via
the terminal contacts.
Power supply
The power supply of the module is 9-12 Volt DC. The idle current of the module is 10-30mA, but
during communication it can reach 2 Amperes as well.
Input
The Tip/Ring input of the alarm center can be connected to the output of phone line simulator
“Alarm Tip/Ring”.
LEDs
•
•
•
The green and the red LEDs show the module status under power
The red LED signs only some kind of activity
the green LED signs the power of the network signal strength in basic position
When the green and the red LEDs are blinking together, then the device is unworkable, the blinking
shows in this case an error code. The error code can be seen on the status window of the WiLARM
Commander software.
4
WiLARM-ContactID EasyPhone
GSM Module
Installation Guide
Version: 2.0
LED operation chart
LED operation chart
Green LED status
Lighting continuously
Meaning
It can not connect to the network
1-2 blinks
Low network signal strength, another place or external antenna is recommended
3 blinks
Reasonable network signal strength, a test call is suggested
4 blinks
Good network signal strength
5 blinks
Excellent network signal strength
Green and red LEDs blink
together
1 villogás
Error code
2 villogás
GSM module error
3 villogás
SIM card is missing
4 villogás
SIM card is locked with PIN code, but the PIN code has not given in the programmer
software
Initialization
Pushbutton
The button is used for adjusting the GSM module, erasing the memory and refreshing the internal
firmware.
Deleting the configuration (master reset)
-
Unplug the device (remove the external power supply), unplug the USB cable
-
Push the reset button while the device is switched off
-
Plug the power supply and release the Reset button immediately
-
The two LEDs of the module light up and blink one
-
When both LEDs turn off, push the Reset button again
-
The green LED shows, that the configuration Reset was successful
-
Unplug the device again
5
WiLARM-ContactID EasyPhone
GSM Module
Installation Guide
Version: 2.0
Refreshing the internal firmware
-
Launch the Wilarm_Upgrade.exe software
-
Unplug the device (remove the power supply), unplug the USB connector
-
Hold on the reset button and plug the USB cable
-
The LEDs light lower, which means, that the module is in BOOT mode
Attention! If you do not start the refreshment within 10 seconds, the module automatically
leaves BOOT mode and restarts itself.
-
Open the firmware with the Open+Upgrade button
-
The refreshment of the internal software has been starting
-
At the end of the process the PASS title signs the successful finish
-
Restart the WiLARM GSM module
SIM holder
The holder of SIM card, (the SIM was bought from the network service provider). The device is
network independent, so it accepts any kind of cards. It is better to switch off the PIN request of the
SIM card
Antenna connector
Standard SMA/F connector. The included stick antenna can be connected here or the optional types
of antennas with extension cables.
Telephone circuit
Attention! On the telephone circuit the voltage can reach 72 Volt as well. Do not touch it under
power!
6
WiLARM-ContactID EasyPhone
GSM Module
Installation Guide
Version: 2.0
The task of the circuit is to create a standard 48V phone line from the power voltage. It can be
measured on the Tip/Ring terminal contacts. The phone line input of the alarm center can be
connected to here.
Prepare for the installation
-
Insert the SIM card to any cellphone, disable the voice mail, activate the caller identity
sending, do a network signal strength measurement
-
Insert a SIM card without PIN code request into the module, connect the power supply and
the center phone line output (Tip/Ring)
Programming with SMS commands
The main parameters of the GSM module can be programmed via SMS commands as well. The
adjustment of the GSM module can be done with the programming SMS commands as well as the
smaller modifications after the installation (phone numbers to alert, etc.).
The detailed commands are available with examples in SMS commands table.
Controlling the GSM module with SMS commands
The device can be maintained via the command SMS (test, arming, switching output, etc.)
The detailed commands are available with examples SMS commands table.
SMS commands
Command description
Example
Commands for programming
Changing the security code
1234pin:4321
Where 1234 is default, 4321 is the new code
Setting up the phone number for SMS redirecting
SETFRW:phone number
Redirecting deleting:
SETFRW: without phone number
1234pin:4321
1234SETFRW:06201234567
1234SETFRW:
Control command
Test request
1234t
In this case the GSM module responds a status SMS containing module type
and temperature.
1234t
7
WiLARM-ContactID EasyPhone
GSM Module
Installation Guide
Version: 2.0
Troubleshooting
Troubleshooting
Error descripition
Solution
ACT LED stays red during alarm.
The module can not send the message because the card is out of credit or a wrong phone
number was given. Check the SMS center number of the module SIM card.
The caller phone number (GSM module) can not
be seen.
The caller ID is disabled on the card.
The module sometimes does not call.
The very old cards (more than 10 years) could cause problem.
The ContactID module does not communicate
with the alarm center.
Measure the Tip/Ring points of the module. Basically it should be 48V. If the center
communicates, it should be 5-8V.
8