Survey
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
WiLARM-ContactID EasyPhone GSM Module Installation Guide Version: 2.0 WiLARM-ContactID EasyPhone GSM Module Installation Guide Version: 2.0 Content Main functions and operation of the GSM module………………………………………………………. 3 Parts of the module……………………………………………………………………………………………………….. 3 Mini USB connector………………………………………………………………………………………………….. 4 Terminal contacts…………..………………………………………………………………………………………… 4 Power supply……………………………………………………………………………………………………………. 4 Input ………………………………………………………………………………………..……………………………… 4 LEDs…………………………………………………………………………………………………………..……………. 4 LED operation chart………………………………………………………………………………………………… 5 Push button…………………………………………………………………………..…………………..…………… 5 Deleting the configuration (master reset)………………………………………………….…….…….. 5 Refreshing the internal firmware…………………………………………………………..………………. 6 SIM holder……………………………………………………………………..……………………………………… 6 Antenna connector………………………………………………………………………………………………… 6 Telephone circuit…………………………………………………………………………………………………… 6 Prepare for the installation…………………………………………………………………………………………… 7 Programming with SMS commands……………………………………………………………..………………. 7 Controlling the GSM module with commands………………………………………………………………. 7 Troubleshooting…………………………………………………………………………………………………………. 8 2 WiLARM-ContactID EasyPhone GSM Module Installation Guide Version: 2.0 Main functions and operation of the GSM module The alarm center starts a ContactID communication and the module forwards it as a GSM phone call to the called number of the monitoring centre. The standard ring voltage appears on the phone line simulator in case of incoming calls (for example alarm center during teleprogramming). Parts of the module 3 WiLARM-ContactID EasyPhone GSM Module Installation Guide Version: 2.0 Mini USB connector The inner software of the module can be refreshed via the mini USB connector. The “WiLARM_Upgrader” software documentation includes the whole detailed user manual. Terminal contacts The power supply and the alarm system’s Tip/Ring input can be connected to the GSM module via the terminal contacts. Power supply The power supply of the module is 9-12 Volt DC. The idle current of the module is 10-30mA, but during communication it can reach 2 Amperes as well. Input The Tip/Ring input of the alarm center can be connected to the output of phone line simulator “Alarm Tip/Ring”. LEDs • • • The green and the red LEDs show the module status under power The red LED signs only some kind of activity the green LED signs the power of the network signal strength in basic position When the green and the red LEDs are blinking together, then the device is unworkable, the blinking shows in this case an error code. The error code can be seen on the status window of the WiLARM Commander software. 4 WiLARM-ContactID EasyPhone GSM Module Installation Guide Version: 2.0 LED operation chart LED operation chart Green LED status Lighting continuously Meaning It can not connect to the network 1-2 blinks Low network signal strength, another place or external antenna is recommended 3 blinks Reasonable network signal strength, a test call is suggested 4 blinks Good network signal strength 5 blinks Excellent network signal strength Green and red LEDs blink together 1 villogás Error code 2 villogás GSM module error 3 villogás SIM card is missing 4 villogás SIM card is locked with PIN code, but the PIN code has not given in the programmer software Initialization Pushbutton The button is used for adjusting the GSM module, erasing the memory and refreshing the internal firmware. Deleting the configuration (master reset) - Unplug the device (remove the external power supply), unplug the USB cable - Push the reset button while the device is switched off - Plug the power supply and release the Reset button immediately - The two LEDs of the module light up and blink one - When both LEDs turn off, push the Reset button again - The green LED shows, that the configuration Reset was successful - Unplug the device again 5 WiLARM-ContactID EasyPhone GSM Module Installation Guide Version: 2.0 Refreshing the internal firmware - Launch the Wilarm_Upgrade.exe software - Unplug the device (remove the power supply), unplug the USB connector - Hold on the reset button and plug the USB cable - The LEDs light lower, which means, that the module is in BOOT mode Attention! If you do not start the refreshment within 10 seconds, the module automatically leaves BOOT mode and restarts itself. - Open the firmware with the Open+Upgrade button - The refreshment of the internal software has been starting - At the end of the process the PASS title signs the successful finish - Restart the WiLARM GSM module SIM holder The holder of SIM card, (the SIM was bought from the network service provider). The device is network independent, so it accepts any kind of cards. It is better to switch off the PIN request of the SIM card Antenna connector Standard SMA/F connector. The included stick antenna can be connected here or the optional types of antennas with extension cables. Telephone circuit Attention! On the telephone circuit the voltage can reach 72 Volt as well. Do not touch it under power! 6 WiLARM-ContactID EasyPhone GSM Module Installation Guide Version: 2.0 The task of the circuit is to create a standard 48V phone line from the power voltage. It can be measured on the Tip/Ring terminal contacts. The phone line input of the alarm center can be connected to here. Prepare for the installation - Insert the SIM card to any cellphone, disable the voice mail, activate the caller identity sending, do a network signal strength measurement - Insert a SIM card without PIN code request into the module, connect the power supply and the center phone line output (Tip/Ring) Programming with SMS commands The main parameters of the GSM module can be programmed via SMS commands as well. The adjustment of the GSM module can be done with the programming SMS commands as well as the smaller modifications after the installation (phone numbers to alert, etc.). The detailed commands are available with examples in SMS commands table. Controlling the GSM module with SMS commands The device can be maintained via the command SMS (test, arming, switching output, etc.) The detailed commands are available with examples SMS commands table. SMS commands Command description Example Commands for programming Changing the security code 1234pin:4321 Where 1234 is default, 4321 is the new code Setting up the phone number for SMS redirecting SETFRW:phone number Redirecting deleting: SETFRW: without phone number 1234pin:4321 1234SETFRW:06201234567 1234SETFRW: Control command Test request 1234t In this case the GSM module responds a status SMS containing module type and temperature. 1234t 7 WiLARM-ContactID EasyPhone GSM Module Installation Guide Version: 2.0 Troubleshooting Troubleshooting Error descripition Solution ACT LED stays red during alarm. The module can not send the message because the card is out of credit or a wrong phone number was given. Check the SMS center number of the module SIM card. The caller phone number (GSM module) can not be seen. The caller ID is disabled on the card. The module sometimes does not call. The very old cards (more than 10 years) could cause problem. The ContactID module does not communicate with the alarm center. Measure the Tip/Ring points of the module. Basically it should be 48V. If the center communicates, it should be 5-8V. 8 WiLARM-ContactID EasyPhone GSM Module Installation Guide Version: 2.0 Hungary- 1115 Budapest Csoka str. 7-13/A Tel: +36-1-466-5665, +36-20-295-2440 E-mail: [email protected] Web: http://www.wilarmsecurity.com 9