Online UPS 1 Back Panel 8 2 7 HP900C/HP900C-RM Series 2 1 Communication Interface 6 Terminal Block 2 Fan 7 Parallel Port 3 Input Breaker 8 SNMP Slot 4 Battery Socket 9 Output Socket 5 Manual Bypass Switch 4 5 3 1:1 Phase 6 4 3 6K VA 1 K VA 0 8 9 2 2 6 1 specifications specifications HP960C Model Power Input Application: Rack mounted server and othe networking equipment Voltage Range Frequency Power Factor 0.98 220Vac 1% Single phase 50HZ 0.2%(battery mode) Voltage Range Phase Frequency High frequency and double conversion on-line technology THD (Linear load) Fully digitized microprocessor control Overload THD (non-Linear load) Crest Factor Wide input voltage range Short Circuit Protection LCD display Waveform <2% < 6% 105 130 10min turn to bypass mode;>130% 1s turn to bypass mode 3:1(max) 5 cycles turn off inverter, no transfer to bypass, provide alarm (AC mode) 5 cycles turn off inverter, provide alarm (battery mode) Input fuse blown or breaker action Pure sine wave Transfer Time Between AC Zero transfer time Mode and Battery Mode Transfer Time Between AC Cold start Zero transfer time Mode and Bypass Mode Parallel capacity 88% Efficiency Type Advanced battery management 12V sealed lead acid maintenance free DC Voltage 240VDC 20 x 12V/7AH Configuration Automatic battery charge in UPS off mode 1 5 6 7 1 2 3 4 5 2 3 4 6 7 LCD ON/OFF Button Self-test/Silence Button Scroll Button Normal Alarm Abnormal Backup Time (half load) Backup Time (full load) Lightning and surge protection Charge Current (standard unit) Charge Current (long time unit) Short circuit and overload protection Recharge Time Fan speed auto control when loads varies Control Panel Battery N/A N/A 1A 5A 90%capacity after 8 hrs charging RS232 ; SNMP (optional) Parallel availability for redundancy and load sharing up to three units Parallel port LCD Indication 1. Input voltage/frequency , battery voltage, output voltage/frequency, load watt/VA value and percent, inverter temperature 2. Operation mode such as LED Indication on line , Noise Level Smart RS232 communication with monitoring software 55dB 0~40 0%~95% (Non-condensing) Humidity Environment on batt , or on bypass 1. Green led for normal operation,2. Yellow led for warning condition3. Red led for abnormal operation Temperature Optional SNMP Card slot 13min 5min N/A N/A Communication Interface <1500m Altitude Storage Temperature Other 0~40 Standard unit Net/Gross Weight 89/104Kg N/A 92/107Kg N/A Long Time Unit Net/Gross Weight 34/48Kg 22/25Kg 36/51Kg 22/25Kg 270 570 720 370 670 940 440 656 176 270 570 720 370 670 940 440 656 176 Dimension (W D H)mm 18 20min 7min Optional extension battery pack EMI/RFI noise filter HP9100C-RM 10KVA/7KW 176 5VAC~276 5VAC 46~54Hz 0.5Hz or 56~64Hz 0.5Hz auto sensing Single phase Phase Output HP9100C HP960C-RM 6KVA/4.2KW Packing (W D H)mm 580 790 336 580 790 336