Survey
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
FLOWCOMPUTER WITH TEMPERATURE AND PRESSURE DATASHEET F126-EG - FLOWCOMPUTER COMPENSATION FOR CORRECTED GAS VOLUME Advantages Signal output • Robust IP67 (NEMA4X) field enclosure. It is so rugged, you can even stand on it! • Intrinsically Safe available - ATEX and IECEx approval for gas and dust applications. • Programming can be done by your own crew, with the sensible menu-driven structure, saving cost and irritation. Know one, know them all! • Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors! • (0)4 - 20mA / 0 - 10V DC according to compensated flow rate. • Scaled pulse output according to accumulated total. Signal input Features • Calculates compensated flow rate, total and accumulated total. • Displays actual line pressure and temperature. • Selectable on-screen engineering units; volumetric or mass. • 7 digit resettable total. • 11 digit accumulated total. • Explosion/flame proof II 2 GD EEx d IIB T5. • Full Modbus communication RS232/485/TTL. • Loop or battery powered, 8 - 24V AC/DC or 115 - 230V AC power supply. 1 Flow • Ability to process all types of flow meter signals: Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), Active pulse signals, (0)4 - 20mA, 0 - 10V DC. Temperature • PT100 - 2 or 3 wire, (0)4 - 20mA, 0 - 10V DC. Pressure • (0)4 - 20mA, 0 - 10V DC. Applications • The F-Series is your first and safest choice for field mount indicators. Especially in harsh weather conditions like rain, snow, salty atmosphers and temperatures between -40°C up to +80°C (-40°F up to 176°F) for safe and hazardous area applications! • Applications where nett gas flow calculation at base conditions is desired. For DIN panel mount indicators, check our D-Series. General information Signal input Introduction The flowcomputer measures the uncorrected volumetric flow, line temperature and pressure. The F126-EG will accept most pulse and analog input signals for flow. The analog flow input is available with lineair and square root calculation and even as 4 - 20mA input loop powered. For the temperature measurement, 2 or 3 wire PT100 elements or sensors with a (0)4 - 20mA / 0 - 10V DC output signal can be used, just as for the pressure measurement. The flowcomputer Model F126-EG has been developed to calculate the gas volume at normal conditions for generic products, in most cases at 0°C (32 °F) and 1.013 Bar. If desired, any other temperature or pressure can be set. The corrected volumetric flow is calculated using the equations stored in the flowcomputer while a compressibility factor can be set to approach a real gas behaviour. Display Communication The display has large 17mm (0.67”) and 8mm (0.31”) digits which can be set to show flow rate, total, temperature and pressure. On-screen engineering units are easily configured from a comprehensive menu. The accumulated total can register up to 11 digits and is backed-up in EEPROM memory every minute. All process data and settings can be read and modified manually or through the Modbus communication link (RS232 / RS485). Full Modbus functionality remains available for the Intrinsically Safe version (TTL). Hazardous areas Configuration This model has been ATEX and IECEx certified Intrinsically Safe for gas and dust applications, with an allowed ambient temperature of -40°C to +70°C (-40°F to +158°F). A flame proof enclosure with ATEX certification offers the rating II 2 GD EEx d IIB T5. All configuration settings are accessed via a simple operator menu which can be password protected. Each setting is clearly indicated with an alphanumerical description, which avoids confusing abbreviations and baffling codes. Once familiar with one F-series product, you will be able to program all models in the series without a manual. All settings are safely stored in EEPROM memory in the event of sudden power failure. Enclosures Various types of enclosures can be selected, all ATEX and IECEx approved. As standard the F126-EG is supplied in a GRP panel mount enclosure, which can be converted to an IP67 / NEMA 4X GRP field mount enclosure by the addition of a back case. Most popular is our rugged aluminum field mount enclosure with IP67 / NEMA 4X rating. Both European or U.S. cable gland entry threads are available. Analog output signal The calculated flow rate is re-transmitted with the (0)4 - 20mA or 0 - 10V DC output signal. The output signal is updated eight times per second with a filter function being available to smoothen out the signal if desired. The output value is user defined in relation to the flow rate, e.g. 4mA equals to 15Nm3/Hr and 20mA equals to 2000Nm3/Hr. The output signal can be passive, active or isolated where the passive output type will loop power the F126-EG as well. Overview application F126-EG Pulse output Pulse output The scaleable pulse output, reflects the count on the accumulated display. The pulse length is user defined from 0.001 second up to 9.999 seconds. The maximum output frequency is 500Hz. The output signal can be passive NPN, active PNP or an isolated electro-mechanical relay. Analog output Communication link Pressure input Temperature input Flow meter input 2 F126-EG 0.9" 0.9" 14mm F126-EG 1 2 / "NPT 15mm 38mm 24mm 24mm 36mm 36mm 1 2 / "NPT 15mm 1 2 / "NPT HT 6 x M12 Ø22 ( 7/8") Ø22 ( 7/8") Ø22 ( 7/8") HK 1.18" 1.18" Flat bottom, no holes available. 1 /2"NPT HU 4 x M20 x 1.5 HV HZ 3 - + + Ø12 Display example - 90 x 40mm (3.5” x 1.6”) PL: input loop powered (terminals GND - 1 - 2 are not available) PB / PC: battery powered Internal long life Lithium battery (terminals GND - 1 - 2 are not available) PX: 8 - 30V DC Output loop powered unit with type AP (terminals GND - 1 - 2 are not available) (With PD / PF / PM terminals 1 / 2 are not available, backlight power supply is integrated.) - PX-ZB: Backlight supply PM: 115 - 230V AC HJ PF: 24V DC 30mm (1.18") 30mm (1.18") + 24mm 24mm 36mm 36mm + M20 x 1,5 - HH PF: 24V AC 12mm 12mm + = = OR: mech. relay Ø20 + HG - M20 x 1,5 I+ I+ I+ I+ U U+ AU: 0 - 10V I AP: 4 - 20mA I- AI: 4 - 20mA I- AF: 4 - 20mA I - - + I+ I+ A - PL: 4 - 20mA U+ U: 0 - 10V A: (0)4 - 20mA + P: active signal P: namur P: PNP + + + + + + 14 + + 15 16 18 19 + + + + TP: PT100 3-wire U+ IU: 0 - 10V (with TA/TU+PF/PM)** I+ 21 TP: PT100 2-wire 20 22 TEMPERATURE INPUT IA: (0)4 - 20mA (with TA/TU+PF/PM)** U+ IU: 0 - 10V (with TA/TU)* I+ IA: (0)4 - 20mA (with TA/TU)* 17 PRESSURE INPUT * Note: If TA / TU is used then IA / IU use terminal 17 - 18 - 19. If TP is used then IA / IU use terminal 12 - 13 - 14. ** Note: If PF / PM and TA / TU is used then IA / IU use terminal 17 only. U+ IU: 0 - 10V (with TP)* I+ IA: (0)4 - 20mA (with TP)* U+ I+ TU: 0 - 10V* P: reed switch / NPN 12 TA: (0)4 - 20mA* I+ I 11 AB: 0 - 20mA 9 P: coil 8 AA: 4 - 20mA 13 Ø16 10 Ø22 ( 7/8") OT: passive trans. 25mm 25mm PD - XI: 16 - 30V DC HP HF 7 M16 x 1,5 Ø20 6 30mm 30mm PD: 8 - 24V DC HO HD 5 M20 x 1,5 PG9 TEMPERATURE INPUT / PRESSURE INPUT GRP OA: active 24V DC Ø16 4 12mm 12mm HN HE 3 M20 x 1,5 HM 112 mm (4.40") 2 25mm HL Ø 7mm (0.27") 1 25mm 23 24 panel cut-out GND M20 x 1,5 25 26 27 A A DTR +12V RXD CT: TTL Intrinsically Safe CI: RS485 - 4 wire 28 RXD CH: RS485 - 2 wire DTR +12V CB: RS232 TXD B B TXD 29 COMMUNICATION 98 (3.86") 115 (4.53") FLOW METER INPUT 60 mm (2.36") 130 mm (5.12") PD: 8 - 24V AC /2"NPT ANALOG OUTPUT 1 PULSE OUTPUT M16 x 1,5 1.18" 22,50mm Aluminum POWER REQUIREMENTS 30mm 30mm HA 22,50mm (0.9") 30mm 30mm 22,50mm 75 mm (2.95") 22,50mm / "NPT Ø 7mm (0.27") 17mm 0.9" 130 mm (5.12") 14mm 1 2 22,50mm HB & HC enclosures 22,50mm (0.9") 22,50mm 1.18" 22,50mm PG9 17mm 29 mm (1.14") 15mm 120 mm (4.72") 31 mm (1.22") + 16mm 120 mm (4.72") Y 30 Z 31 Dimensions enclosures Terminal connections Aluminum & GRP panel mount enclosure Aluminum & GRP field / wall mount enclosures Ø20 Typical wiring diagram F126-P-AP-CH-EG-IA-OT-PX-TA Typical wiring diagram F126-P-AI-CI-EG-IA-OA-PD-TA Z 31 Y 30 29 28 26 Common ground Signal 19 Pressure input type IA: (0)4 - 20mA Signal 10 Flow meter input type: P pulse 14 11 Supply * Signal Common ground 8 e.g. counter Pulse output type OT: passive transistor Common ground 6 123456 e.g. counter Pulse output type OA: active 24V DC pulse 5 6 - 5 123456 + 7 - Analog output type AP: passive 4 - 20mA (loop powered) Analog output type AI: passive isolated 4 - 20mA 8 - 30V DC 8 - 30V DC 7 8 + Common ground Flow meter input type: P pulse indicator indicator Common ground 10 Circuit depends on type of signal 12 11 Signal 12 13 Signal Common ground Supply * Common ground Supply * Temperature input type TA: (0)4 - 20mA 9 Circuit depends on type of signal 14 13 Signal 17 18 17 Temperature input type TA: (0)4 - 20mA Supply * Common ground Circuit depends on type of signal Common ground 9 Circuit depends on type of signal Common ground Pressure input type IA: (0)4 - 20mA 18 Signal 26 28 A - Common ground B Modbus communication type CI: RS485 - 4 wire + A 29 Modbus communication type CH: RS485 - 2 wire B 24V AC / DC POWER SUPPLY TERMINAL CONNECTORS F100 - series OUTPUT LOOP POWERED TERMINAL CONNECTORS F100 - series 0 8 - 24V DC - 1 + Common ground Power supply type PD: 8 - 24V AC / DC Earth *Supply voltage: 1.2 / 3.2 / 8.2 / 12 / 24V DC to sensor *Supply voltage: 1.2 / 3.2V DC to sensor 4 F126-EG Typical wiring diagram F126-A-AA-CB-EG-IA-OR-PM-TP Typical wiring diagram F126-P-AI-CI-EG-IA-OR-PM-TA 80 - 230V AC POWER SUPPLY 29 28 26 DTR +12V Common ground 115 - 230V AC POWER SUPPLY Modbus communication type CI: RS485 - 4 wire 26 29 A RXD 27 B TXD Common ground Y 28 Modbus communication type CB: RS232 Z 31 TERMINAL CONNECTORS F100 - series 30 TERMINAL CONNECTORS F100 - series 22 Signal Temperature input type TP: PT100 3 - wire 21 Signal 20 Supply Signal 14 13 Signal Common ground 9 12 11 Circuit depends on type of signal 10 Signal Supply * 10 13 12 11 Flow meter input type A: (0)4 - 20mA Temperature input type TA: (0)4 - 20mA Signal Common ground Supply * Common ground Supply * Flow meter input type: P pulse 9 Pressure input type IA: (0)4 - 20mA Signal Common ground Circuit depends on type of signal Circuit depends on type of signal 14 Supply * indicator 8 7 e.g. counter Main supply L1 Common ground Protective earth *Supply voltage: 3.2 / 8.2 / 12 / 24V DC to sensor F126-EG 2 N 123456 e.g. counter Pulse output type OR: mechanic relay Power supply type PM: 115 - 230V AC 1 Power supply type PM: 115 - 230V AC 5 Pulse output type OR: mechanic relay 0 Common ground 6 123456 1 2 5 6 7 - Main supply 8 - 30V DC 0 + Common ground Analog output type AA: active 4 - 20mA *Supply voltage: 3.2 / 8.2 / 12 / 24V DC to sensor 5 Analog output type AI: passive isolated 4 - 20mA - 8 e.g. indicator + Circuit depends on type of signal 17 Pressure input type IA: (0)4 - 20mA N L1 Protective earth Certificate of conformity KEMA 03ATEX1074 X • IECEx DEK 11.0042X Hazardous area applications The F126-EG-XI has been certified according ATEX and IECEx by DEKRA for use in Intrinsically Safe applications with an ambient temperature of -40°C to +70°C (-40°F to +158°F). • The ATEX markings for gas and dust applications are: II 1 G Ex ia IIB/IIC T4 Ga II 1 D Ex ia IIIC T100 °C Da IP6X. • The IECEx markings for gas and dust applications are: Ex ia IIC/IIB T4 Ga and Ex ia IIIC T100 °C Da IP6X. It is allowed to connect up to six barriers in IIB/IIIC applications or one barrier in IIC applications. Consult the certificate for the maximum input and output values of the circuits. Full functionality of the F126-EG remains available, including 4 - 20mA output according to the flow rate and Modbus communication (type CT). Power supply type PD-XI offers a 8.2V sensor supply e.g. for one Namur sensor and two analog sensors. A flame proof enclosure with rating ATEX II 2 GD EEx d IIB T5 is available as well. Please contact your supplier for further details. Configuration example IIB / IIIC and IIC - F126-P-(AP)-(CT)-EG-IA-(OT)-PC-TP-XI - Battery powered unit HAZARDOUS AREA TERMINAL CONNECTORS F100-series SAFE AREA Modbus communication type CT: TTL Possible for battery powered applications (not used in this example). 22 Signal Temperature input type TP: PT100 3 - wire 21 Signal Supply * 14 Ci is negligibly small 12 11 Flow meter input type: P pulse 8 6 7 Analog output type AP: passive 4 - 20mA (not used in this example). Please note: type AP may be used in combination with the battery (type PC), but only in IIB applications! AP will power the unit (output loop powered); the battery will be disabled automatically till power is disconnected). Pulse output type OT: passive transistor (not used in this example) 5 Common ground Ci is negligibly small 9 10 Signal Common ground Po=max 750mW REPEATER For example MTL 5541 Note: above values are safety values. Consult the technical specification for operational values. Supply * Common ground Uo=max 30V Io=max 100mA - 13 Signal Common ground Circuit depends on type of signal Pressure input type IA: (0)4 - 20mA + Circuit depends on type of signal 20 Supply * Note sensor supply voltage: 1.2V DC for coil sensors or 3.2V DC for other pulse sensors. 6 F126-EG Configuration example IIB / IIIC - F126-P-AP-CT-EG-IA-OT-PX-TP-XI - Output loop powered HAZARDOUS AREA TERMINAL CONNECTORS F100-series SAFE AREA TXD 29 Modbus communication type CT: TTL RXD 28 Uo=max 30V e.g. PC Po=max 850mW For example: MTL5051 26 - Common ground 27 + DTR +12V Io=max 250mA ISOLATOR: I.S. Certified Isolator TTL to RS232 / RS422 / TTL 22 Signal Temperature input type TP: PT100 3 - wire 21 Signal Supply * 14 Ci is negligibly small Uo=max 30V Po=max 750mW + 12 Io=max 100mA - 13 Signal Common ground Uo=max 30V REPEATER For example MTL 5541 11 Supply * Flow meter input type: P pulse 9 Ci is negligibly small Common ground Io=max 100mA 7 Analog output type AP: passive 4 - 20mA (output loop powered) Ci is negligibly small Pulse output type OT: passive transistor 123456 Po=max 750mW Uo=max 30V Po=max 750mW Io=max 100mA e.g. counter 5 6 Common ground - 8 e.g. indicator Ci = 17nF - Common ground 10 Signal + Circuit depends on type of signal Pressure input type IA: (0)4 - 20mA + Circuit depends on type of signal 20 Supply POWER SUPPLY e.g. MTL 5525 and / or REPEATER e.g. MTL 5541 POWER SUPPLY e.g. MTL 5525 or SWITCH INTERFACE e.g. MTL 5511 e.g. indicator 123456 e.g. counter Note: above values are safety values. Consult the technical specification for operational values. * Note sensor supply voltage: 1.2V DC for coil sensors or 3.2V DC for other pulse sensors. F126-EG 7 Configuration example IIB / IIIC and IIC - F126-A-AF-(CT)-EG-IA-OT-PD-TA-XI - Power requirement 16 - 30V DC HAZARDOUS AREA TERMINAL CONNECTORS F100-series SAFE AREA RXD Uo=max 30V 28 TXD 29 Modbus communication type CT: TTL Please note: communciation type CT is not allowed in IIC applications. Po=max 850mW e.g. PC For example: MTL5051 26 - Common ground 27 + DTR +12V Io=max 250mA ISOLATOR: I.S. Certified Isolator TTL to RS232 / RS422 / TTL TOTAL Co OF ALL CONNECTED ANALOG APPARATUS IN IIC APPLICATIONS MAY NOT EXCEED 66nF MINUS 17nF (17nF IS USED BY THE ANALOG OUTPUT SIGNAL TERMINAL 7 + 8). Signal 18 Circuit depends on type of signal * Note: Communication only allowed when configured as IIB / IIIC. Ci is negligibly small Pressure input type IA: (0)4 - 20mA 14 Ci is negligibly small 12 13 Signal Common ground Flow meter input type: A (0)4 - 20mA 11 Supply * Signal Ci is negligibly small Analog output type AF: passive floating 4 - 20mA Ci = 17nF e.g. indicator Pulse output type OT: passive transistor 123456 5 Uo=max 30V Io=max 100mA e.g. counter - Common ground Ci is negligibly small + 6 7 8 Common ground 10 Circuit depends on type of signal Temperature input type: TA (0)4 - 20mA Supply * 9 Circuit depends on type of signal 17 Common ground Po=max 750mW POWER SUPPLY e.g. MTL 5525 or SWITCH INTERFACE e.g. MTL 5511 123456 e.g. counter 2 Note: above values are safety values. Consult the technical specification for operational values. Power supply type PD: 16 - 30V DC (please note: PD and battery supply (type PC) is NOT allowed in IIC applications). 0 Uo=max 30V Io=max 100mA - Common ground 1 + Main supply Po=max 750mW POWER SUPPLY For example MTL 5525 Note: above values are safety values. Consult the technical specification for operational values. * Note power supply type PD: the supply voltage to pulse sensors is maximum 8.7V (Uo=max 8.7V Io=max 25mA Po=max 150mW) and to analog sensors as connected to terminal 1 (internally linked). 8 F126-EG Configuration example IIB / IIIC - F126-A-AF-CT-EG-IA-OT-(PC)-(PD)-TA-XI - Power requirement 16 - 30V DC or battery powered HAZARDOUS AREA TERMINAL CONNECTORS F100-series SAFE AREA TXD 29 Modbus communication type CT: TTL 28 Uo=max 30V RXD 26 18 Ci is negligibly small 17 - Supply * 14 + 12 11 + 9 7 123456 Uo=max 30V Po=max 750mW Io=max 100mA e.g. counter 5 Pulse output type OT: passive transistor Po=max 750mW - e.g. counter Ci is negligibly small Uo=max 30V Io=max 100mA + 8 Analog output type AF: passive floating 4 - 20mA Po=max 750mW - Ci = 17nF Uo=max 30V Io=max 100mA + 10 Ci is negligibly small e.g. indicator 6 Po=max 750mW REPEATER For example MTL 5541 Flow meter input type A: (0)4 - 20mA Signal Common ground Uo=max 30V Io=max 100mA - 13 Ci is negligibly small Supply * Common ground Po=max 750mW REPEATER For example MTL 5541 Temperature input type TA: (0)4 - 20mA Signal Common ground Uo=max 30V Io=max 100mA - Circuit depends on type of signal Signal + Circuit depends on type of signal For example: MTL5051 Pressure input type IA: (0)4 - 20mA Common ground Circuit depends on type of signal Po=max 850mW e.g. PC - Common ground 27 + DTR +12V Io=max 250mA ISOLATOR: I.S. Certified Isolator TTL to RS232 / RS422 / TTL REPEATER For example MTL 5541 POWER SUPPLY e.g. MTL 5525 and / or REPEATER e.g. MTL 5541 POWER SUPPLY e.g. MTL 5525 or SWITCH INTERFACE e.g. MTL 5511 e.g. indicator 123456 e.g. counter 1 0 Common ground Uo=max 30V Io=max 100mA Power supply type PD: 16 - 30V DC - Main supply Due to analog output type AF, the unit has to be powered with battery type PC or with external power supply type PD. + 2 Note: above values are safety values. Consult the technical specification for operational values. Po=max 750mW POWER SUPPLY For example MTL 5525 Note: above values are safety values. Consult the technical specification for operational values. * Note power supply type PD: the supply voltage to pulse sensors is maximum 8.7V (Uo=max 8.7V Io=max 25mA Po=max 150mW) and to analog sensors as connected to terminal 1 (internally linked). F126-EG 9 Directives & Standards Technical specification EMC Low voltage ATEX / IECEx General Display Type Dimensions Digits Refresh rate Option ZB Note ZB High intensity reflective numeric and alphanumeric LCD, UV-resistant. 90 x 40mm (3.5” x 1.6”). Seven 17mm (0.67") and eleven 8mm (0.31") digits. Various symbols and measuring units. User definable: fast, 1sec , 3sec, 15sec, 30sec, off. Transflective LCD with adjustable green LED backlight. Good readings in full sunlight and darkness. Only available for safe area applications. IP & NEMA Enclosure General Window Sealing Control keys General Safe areas -40°C to +80°C (-40°F to +176°F). Intrinsically Safe -40°C to +70°C (-40°F to +158°F). Dimensions Weight Power requirements Type HA Type HL Type HM Type HN Type HO Type HP Type HT Type HU Type HV Type HZ Type PB Sensor excitation Type PB/PC/PX Note Type PD Type PD-XI Note Type PF / PM General Dimensions Weight Type HD Type HE F Type H Type HG Type HH Type HJ Type HK 3.2V DC for pulse signals and 1.2V DC for coil pick-up. This is not a real sensor supply. Only suitable for sensors with a very low power consumption like coils (sine wave) and reed-switches. 1.2 / 3.2 / 8.2 / 12 / 24V DC - max. 50mA @ 24V DC. 1.2 / 3.2 / 8.2V DC - max. 7mA @ 8.2V DC and mains power supply voltage (as connected to terminal 1). In case PD-XI and signal A or U: the sensor supply voltage is according to the power supply voltage connected to terminal 1. The sensor supply of the second analog input is fixed 8.2V DC. 1.2 / 3.2 / 8.2 / 12 / 24V DC - max. 400mA @ 24V DC. Password GRP wall/field mount enclosure IP67 / NEMA 4X, UV-resistant and flame retardant. 130 x 120 x 75mm (5.12" x 4.72" x 2.95") - W x H x D. 600 gr. Cable entry: no holes. Cable entry: 2 x Ø 16mm and 1 x Ø 20mm. Cable entry: 1 x Ø 22mm (7/8"). Cable entry: 2 x Ø 20mm. Cable entry: 6 x Ø 12mm. Cable entry: 3 x Ø 22mm (7/8"). Flat bottom, cable entry: no holes. Panel mount enclosures Dimensions Panel cut-out Type HB Weight Type HC Weight 130 x 120 x 60mm (5.12" x 4.72" x 2.36") - W x H x D. 115 x 98mm (4.53" x 3.86") L x H. Die-cast alu. panel mount enclosure IP65 / NEMA 4X. 600 gr. GRP panel mount enclosure IP65 / NEMA 4X, UV-resistant and flame retardant. 450 gr. Hazardous area Intrinsically Safe (Type XI) ATEX certification IECEx certification Ambient Ta Removable plug-in terminal strip. Wire max. 1.5mm2 and 2.5mm2. Data protection Type Die-cast aluminum wall/field mount enclosure IP67 / NEMA 4X with 2-component UV-resistant coating. 130 x 120 x 75mm (5.12" x 4.72" x 2.95") - W x H x D. 1100 gr. Cable entry: 2 x PG9 and 1 x M20. Cable entry: 2 x 1/2" NPT. Cable entry: 2 x M16 and 1 x M20. Cable entry: 1 x M20. Cable entry: 2 x M20. Cable entry: 6 x M12. Cable entry: 1 x 1/2" NPT. Cable entry: 3 x 1/2" NPT. Cable entry: 4 x M20. Cable entry: no holes. GRP wall / field mount enclosures Terminal connections Type Polycarbonate window. Silicone. Three industrial micro-switch keys. UV-resistant silicone keypad. Aluminum wall / field mount enclosures Ambient temperature Long life Lithium battery - life-time depends upon settings and configuration - up to 5 years. Type PC Intrinsically Safe long life lithium battery - life-time depends upon settings and configuration - up to 5 years. Type PD 8 - 24V AC / DC ± 10%. Power consumption max. 10 Watt. Intrinsically Safe: 16 - 30V DC; power consumption max. 0.75 Watt. F Type P 24V AC / DC ± 10%. Power consumption max. 15 Watt. Type PL Input loop powered from sensor signal 4 - 20mA (type “A”) - requires types AI (not Xi). Type PM 115 - 230V AC ± 10%. Power consumption max. 15 Watt. Type PX 8 - 30V DC. Power consumption max. 0.5 Watt. Type ZB 12 - 24V DC ± 10% or internally powered with type PD / PF / PM. Power consumption max. 1 Watt. Note PB/PF/PM Not availble Intrinsically Safe. Note PF/PM The total consumption of the sensors and outputs may not exceed 400mA @ 24V. Note For Intrinsically Safe applications, consult the safety values in the certificate. Directive 2004/108/EC, FCC 47 CFR part 15. Directive 2006/95/EC Directive 94/9/EC, IEC 60079-0, IEC 60079-11, IEC 60079-26. EN 60529 & NEMA 250 EEPROM backup of all settings. Backup of running totals every minute. Data retention at least 10 years. Configuration settings can be password protected. II 1 G Ex ia IIB/IIC T4 Ga. II 1 D Ex ia IIIC T100 °C Da IP6X. Ex ia IIC/IIB T4 Ga. Ex ia IIIC T100 °C Da IP6X. -40°C to +70°C (-40°F to +158°F). Explosion proof (Type XF) ATEX certification Dimensions Weight 10 II 2 GD EEx d IIB T5. 300 x 250 x 200mm (11.8" x 9.9" x 7.9") L x H x D. Appr. 15kg. Signal inputs Flow meter Operator functions Displayed functions Type P Coil / sine wave (HI: 20mVpp or LO: 80mVpp sensitivity selectable), NPN/PNP, open collector, reedswitch, Namur, active pulse signals 8 - 12 and 24V DC. Frequency Minimum 0Hz - maximum 7kHz for total and flow rate. Maximum frequency depends on signal type and internal low-pass filter. E.g. reed switch with low-pass filter: max. frequency 120Hz. K-Factor 0.000010 - 9,999,999 with variable decimal position. Low-pass filter Available for all pulse signals. Option ZF coil sensitivity 10mVpp. Type A (0)4 - 20mA. Analog input signal can be scaled to any desired range within 0 - 20mA. Type U 0 - 10V DC. Analog input signal can be scaled to any desired range within 0 - 10V DC. Accuracy Resolution: 14 bit. Error < 0.025mA / ± 0.125% FS. Low level cut-off programmable. Span 0.000010 - 9,999,999 with variable decimal position. Update time Four times per second. Voltage drop Type A: 2.5V @ 20mA. Load impedance Type U: 3kOhm. Relationship Linear and square root calculation. Note For signal type A and U: external power to sensor is required; e.g. type PD. Temperature Accuracy Update time Type TA Span Offset Voltage drop Type TP Range Option ZV Type TU Total Digits Units Decimals Note Pressure Accuracy Digits 11 digits. Units / decimals According to selection for total. Note Can not be reset to zero. Flow rate Digits Units Decimals Time units Update time Type IA Span Offset Voltage drop Digits Units Decimals Digits Units Decimals 2.5V @ 20mA. 2 or 3 wire PT100. -100°C to +200°C (-148°F to 392°F). Accuracy 3°C (5.4°F). Range: -200°C to +800°C (-328°F to 1832°F). Accuracy 3°C (5.4°F). 0 - 10V DC. Analog input signal can be scaled to any desired range within 0 - 10V DC. 0.000010 - 9,999,999 K with variable decimal position. Function Frequency Type OA Type OR Type OT For signal TA and TU: power supply to temperature sensor is required; e.g. PD. Function Accuracy Update time Type AA Type AB F Type A Type AI Type AP Type AU Normal press. Normal temp. )( Transmitting compensated flow rate. 10 bit. Error < 0.05%. Analog output signal can be scaled to any desired range. Eight times per second. Active 4 - 20mA output (requires PD or PM). Active 0 - 20mA output (requires PD or PM). Passive floating 4 - 20mA output for Intrinsically Safe applications (requires XI + PC or PD). Passive galvanically isolated 4 - 20mA output - also available for battery powered models (requires PB, PD, PL or PM). Passive 4 - 20mA output - not isolated. Unit will be loop powered. Active 0 - 10V DC output (requires PD or PM). Communication option Function Operational Flow equations ( Pulse output - transmitting accumulated total. Max. 500Hz. Pulse length user definable between 0.001 second up to 9.999 seconds. One active 24V DC transistor output (PNP); max. 50mA per output (requires -PD, PF or PM). One electro-mechanical relay output - isolated; max. switch power 230V AC (N.O.) - 0.5A per relay (requires PF or PM). One passive transistor output (NPN) - not isolated. Max. 50V DC - 300mA per output. Analog output 0.000 - 9,999.999. Corrected gas volume. P Tnormal Qnormal = Q x x Pnormal T Default: 1.013 bar. Default: 273.15K (0°C / 32°F) 6 digits. mbar, bar, PSI, no-unit. 1. Signal outputs Digital output 0.00 - 99,999.99 K. 2.5V @ 20mA. 0 - 10V DC. Analog input signal can be scaled to any desired range within 0 - 10V DC. Span 0.000010 - 9,999,999 with variable decimal position. Load impedance 3kOhm. Note For signal type IA and IU: external power to sensor required; e.g. PD. Formula 6 digits. °C, °F or K. 1. Line pressure Type IU Type EG 7 digits. mL, L, m3, Gallons, kg, Ton, lb, bl, cf, RND, ft3, scf, Nm3, Nl, igal - no units. 0 - 1 - 2 or 3. /sec - /min - /hr - /day. Line temperature Resolution: 14 bit. Error < 0.025mA / ± 0.125% FS. Low level cut-off programmable. Four times per second. (0)4 - 20mA. Analog input signal can be scaled to any desired range within 0 - 20mA. 0.000010 - 9,999,999 K with variable decimal position. Resolution: 14 bit. Error < 0.025mA / ± 0.125% FS. Low level cut-off programmable. Four times per second. (0)4 - 20mA. Analog input signal can be scaled to any desired range within 0 - 20mA. 0.000010 - 9,999,999 with variable decimal position. 7 digits. L, m3, GAL, USGAL, kg, lb, bbl, no unit. 0 - 1 - 2 or 3. Total can be reset to zero. Accumulated total Span Offset 0.00 - 99,999.99 K. Load impedance 3kOhm. Note 1 • Compensated flow rate. • Compensated total and accumulated total. • Actual line temperature. • Actual line pressure • Reset total by pressing the CLEAR-key twice. Protocol Speed Addressing Type CB Type CH Type CI Type CT ) x ( C C ). normal 11 Reading display information, reading / writing all configuration settings. Modbus RTU. 1200 - 2400 - 4800 - 9600 baud. Maximum 255 addresses. RS232 RS485 2-wire RS485 4-wire TTL Intrinsically Safe. Ordering information Standard configuration: F126-P-AP-CX-EG-HC-IA-OX PX-TA-XX-ZX. Ordering information: F126 -_ -A _ -C _ Flow meter input signal A P U -EG -H _ -I _ -OX -P _ -T _ -X _ -Z _ (0)4 - 20mA input. Pulse input: coil, npn, pnp, namur, reed-switch. 0 - 10V DC input. Analog output signal AA AB F A AI AP AU Active 4 - 20mA output - requires PD or PM. Active 0 - 20mA output - requires PD or PM. I.S. floating 4 - 20mA output - requires XI + PC or PD. Isolated 4 - 20mA output - requires PB, PD, PL or PM. Passive 4 - 20mA output, loop powered unit. Active 0 - 10V DC output - requires PD or PM. Communication CB CH CI CT CX Communication RS232 - Modbus RTU. Communication RS485 - 2wire - Modbus RTU. Communication RS485 - 4 wire - Modbus RTU. Intrinsically Safe TTL - Modbus RTU. No communication. EG Corrected gas volume. HB HC Aluminum enclosure. GRP enclosure. Flow equations Panel mount enclosures - IP65 / NEMA4X GRP field / wall mount enclosures - IP67 / NEMA4X HHD HE F H HG HH HJ HK Cable entry: no holes. Cable entry: 2 x Ø 16mm & 1 x Ø 20mm. Cable entry: 1 x Ø 22mm (7/8”). Cable entry: 2 x Ø 20mm. Cable entry: 6 x Ø 12mm. Cable entry: 3 x Ø 22mm (7/8”). Flat bottom, cable entry: no holes. Aluminum field / wall mount enclosures - IP67 / NEMA4X HA HL HM HN HO HP HT HU HV HZ Cable entry: 2 x PG9 + 1 x M20. Cable entry: 2 x 1/2”NPT. Cable entry: 2 x M16 + 1 x M20. Cable entry: 1 x M20. Cable entry: 2 x M20. Cable entry: 6 x M12. Cable entry: 1 x 1/2”NPT. Cable entry: 3 x 1/2”NPT. Cable entry: 4 x M20. Cable entry: no holes. IA IU (0)4 - 20mA input. 0 - 10V DC input. OA OR OT One active transistor outputs - requires PD, PF or PM. One mechanical relay outputs - requires PF or PM. One passive transistor outputs - standard configuration. Pressure input signal Digital output signals Power requirements PB PC PD F P PL PM PX Lithium battery powered. Lithium battery powered - Intrinsically Safe. 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC. 24V AC/DC + sensor supply. Input loop powered from sensor signal type “A” - requires AI (not Xi). 115 - 230V AC + sensor supply. Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP. TA TP TU (0)4 - 20mA input. PT100 input. 0 - 10V DC input. Hazardous area XI F X XX Intrinsically Safe, according ATEX and IECEx. EExd enclosure - 3 keys. Safe area only. ZB F Z ZV ZX Adjustable backlight. Coil input 10mVpp. PRTD-range -200°C / +800°C. No options. Other options The bold marked text contains the standard configuration. / Available Intrinsically Safe. Fluidwell bv P.O. Box 6 5460 AA - Veghel - The Netherlands Telephone: +31 (0)413 343 786 Telefax: +31 (0)413 363 443 email: [email protected] Internet: www.fluidwell.com Specifications are subject to change without notice. 12 Copyright: Fluidwell bv - 2015 - F126EG-DATA-EN-V1540 Temperature input signal