VAX-2-AC BLOWERS C-5166 AC Vaneaxial Blowers general design specification: Motor to MIL-M-7969 airflow: 50 cfm @ 2.1" H20 voltage: 115 VAC, 1 or 3 phase; 200 VAC, 3 phase impeller: Dynamically balanced, precision cast aluminum housing: Precision die-cast aluminum bearings: Double shielded, life-lubricated for –55°C to +85°C operation. Special lubricants available for temperature extremesp electrical connections: Solder terminals are standard. Leads are optional mounting: Mounting can be made by three bolts through flange or by clamp around housing marking: Per MIL-STD-130 life: 1,000 hours at 125°C, 19,500 rpm; 2,000 plus hours at 125°C, 11,000 rpm Dimensions 1.500 MAX .281 72° ref ROTATION 2.6563 DIA MAX OVER MOUNTING LUGS 12° REF TERMINAL "A" AIRFLOW TERMINAL "B" 2.000 MAX TERMINAL "C" 2.7813 DIA MAX OVER TERMINALS TERMINAL "D" (BLANK) .180/.166 DIA THRU 3 HOLES EQUALLY SPACED ON 2.312 DIA BOLT CIRCLE NOTE: Optional leads are #32 AWG leads per MIL-W-16878/4 with exit at location of terminal “D” (8") NOTE: Consult factory prior to preparing spec control prints. Dimensions are for reference only 78 © 1/01 Globe Motors C-5166 Standard Part Numbers and Data VOLTAGE (VAC) 115 115 115 200 200 FREQUENCY (Hz) 400 400 400 400 400 P H A S E 1 1 3 3 3 SPEED min @ free air (rpm) 10,000 19,000 19,500 10,500 19,500 AIRFLOW min @ free air (cfm) 35 65 65 33 65 STANDARD POWER PART INPUT WEIGHT NUMBER* max CAPACITOR max SCHEMATIC (with SCHEMATIC (watts) (µF) (wvdc) (oz.) WIRING terminals) WIRING 20 .15 220 5.0 A 19A2533 A 55 1.50 400 5.0 A 19A790 A 45 — — 5.0 A 19A790 A 15 — — 5.0 B 19A1150 D 45 — — 5.0 C 19A774 C STANDARD PART NUMBER* (with leads) 19A2535 19A1199 19A1199 19A1200 19A1198 Note: All 3-phase voltages are line to line. MIL-STD-704 is 200V line-to-line *When You Order Units shown above are standard and may be ordered by part number. Motor windings, voltage, frequency, speed, current and airflow can usually be modified to fit your needs Typical Performance 3.0 76.2 63.5 50.8 2.0 38.1 1.5 AIRFLOW 1.0 25.4 12.7 .5 50 40 POWER (watts) OPERATING RANGE 2.5 STATIC PRESSURE (mm H 2O) 20 STATIC PRESSURE (in. H 2O) 30 60 30 20 0 0 10 20 30 40 50 60 4.0 POWER (1 PHASE) 3.5 POWER 3.0 (3 PHASE) 16 1.6 88.9 14 1.4 76.2 2.5 63.5 2.0 50.8 1.5 38.1 25.4 1.0 AIRFLOW .5 0 0 70 101.6 OPERATING RANGE 12.7 12 10 8 6 4 2 STATIC PRESSURE (in. H 2O) 88.9 POWER POWER (watts) 50 3.5 STATIC PRESSURE (in. H 2O) 4.0 Part No.: 19A1150, 19A1200 Voltage: 200 VAC Operating Point: 21 cfm @ .5" H2O STATIC PRESSURE (mm H 2O) 101.6 60 40 POWER (watts) Part No.: 19A790, 19A1199 Voltage: 115 VAC Operating Point: 47 cfm @ 2.1" H2O DC & AC Vaneaxial Blowers Part No.: 19A774, 19A1198 Voltage: 200 VAC Operating Point: 50 cfm @ 2.1" H2O POWER 1.2 1.0 OPERATING RANGE .8 .6 .4 AIRFLOW .2 0 10 20 30 40 50 60 70 0 5 10 15 20 25 30 35 AIRFLOW (cfm) AIRFLOW (cfm) AIRFLOW (cfm) Schematic Wiring A A RED B D C B A RED A RED D B C BLACK YELLOW ABC PHASE SEQUENCE FOR CW ROTATION (VIEWING PROP. END). TO RUN SINGLE PHASE CONNECT LINE TO A & C, CAPACITOR TO B & C © 1/01 Globe Motors C A ABC PHASE SEQUENCE FOR CW ROTATION (VIEWING PROP. END) B C BLACK WHITE ABC PHASE SEQUENCE FOR CW ROTATION (VIEWING PROP. END) B C BLACK BLUE ABC PHASE SEQUENCE FOR CW ROTATION (VIEWING PROP. END) 79